Electrical stimulation of the auditory nerve: II. Effect of stimulus waveshape on single fibre response properties
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024 · cited 5×
“While a cathode will result in depolarisation of neural membrane proximal to the electrode, an anode will hyperpolarise that region of the membrane; depolarisation will only occur at more distal sites (Ranck, 1975; Mortimer, 1981).”
InfluentialA theory of the effects of fibre size in medullated nerve
Rushton, W. A. H. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004655 · Cited by 1,075 · cited 2×
“4 Wm (Rushton, 1951), a latency shift of 90 Ws (the di¡erence between the mean anodic and cathodic monophasic latencies) is equivalent to a distance of approximately 1.”
InfluentialRf, G. (1985) · Cited by 949
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833 · cited 2×
“... relationship between threshold current and stimulus duration (the classical strength-duration curve) has been demonstrated by many electrophysiological and modeling studies (electrophysiological studies : auditory nerve : van den Honert and Stypulkowski, 1984; Parkins and Colombo, 1987; Parkins, 1989; Clopton et a…”
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Rate versus level functions for auditory-nerve fibers in cats: tone-burst stimuli
Sachs, M. B., & Abbas, P. J. (1974) · The Journal of the Acoustical Society of America · doi:10.1121/1.1903521 · Cited by 521 · cited 1×
“Slope, dynamic range, and threshold and saturation rates were determined from rate-intensity (input-output) functions by least-squares ¢ts of a saturating function (Sachs and Abbas, 1974).”
Liberman, M. C. (1980) · Hearing Research · doi:10.1016/0378-5955(80)90007-6 · Cited by 415 · cited 1×
“These results might be expected due to variation in the diameter of nodes of Ranvier ^ both on the same ¢bre and across ¢bres (Liberman, 1980).”
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 359 · cited 3×
“While biphasic current pulses are almost universally used clinically, from an electrochemical point of view other short duration charge-balanced current pulses would also appear to be suitable (Brummer and Turner, 1977; Robblee and Rose, 1990).”
Physiological Considerations in Artificial Stimulation of the Inner Ear
Kiang, N. Y. S., & Moxon, E. C. (1972) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947208100513 · Cited by 342 · cited 1×
“5 ms) response (Moxon, 1967, 1971; Kiang and Moxon, 1972 ; Hartmann et al., 1984; van den Honert and Stypulkowski, 1984, 1987a,b; Javel et al., 1987 ; Parkins and Colombo, 1987; Parkins, 1989; Hartmann and Klinke, 1990 ; Javel, 1990; Dynes, 1996; Shepherd and Javel, 1997).”
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334 · cited 1×
“A number of psychophysical studies have identi¢ed two forms of stimulus interaction associated with electrical stimulation of the auditory nerve (e.g. Eddington et al., 1978 ; Shannon, 1983; White et al., 1984; Favre and Pelizzone, 1993).”
Cited by
How cochlear implants encode speech
Rubinstein, J. T. (2004) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/01.moo.0000134452.24819.c0 · Cited by 209
Ramekers, D., Versnel, H., Strahl, S. B., Smeets, E. M., Klis, S. F. L., & Grolman, W. (2014) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-013-0440-x · Cited by 198
Delayed Maturation and Sensitive Periods in the Auditory Cortex
Kral, A., Hartmann, R., Tillein, J., Heid, S., & Klinke, R. (2001) · Audiology and Neurotology · doi:10.1159/000046845 · Cited by 193
“…cochlear place information [Hartmann et al., 1984; van den Honert and Stypulkowski, 1987; Kral et al., 1998], temporal information is reliably represented [Hartmann et al., 1984; van den Honert and Stypulkowski, 1984; Knauth et al., 1994; Shepherd and Javel, 1997, 1999; Javel and Shepherd, 2000].”
Electrical stimulation of the auditory nerve
Javel, E., & Shepherd, R. K. (2000) · Hearing Research · doi:10.1016/s0378-5955(99)00186-0 · Cited by 179
Self-citationPrado-Guitierrez, P., Fewster, L. M., Heasman, J. M., McKay, C. M., & Shepherd, R. K. (2006) · Hearing Research · doi:10.1016/j.heares.2006.03.006 · Cited by 173
Self-citation
Metadata
- Authors
- Shepherd, R. K., & Javel, E.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 130
- Issue
- 1-2
- Pages
- 171-188
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W1972466699
- Cited by
- 186
- References
- 53
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical stimulation of the auditory nerve: II. Effect of stimulus waveshape on single fibre response properties. https://app.cochat.ai/papers/10.1016/s0378-5955(99)00011-8
- The paper
- Shepherd, R. K., & Javel, E. (1999). Electrical stimulation of the auditory nerve: II. Effect of stimulus waveshape on single fibre response properties. Hearing Research. https://doi.org/10.1016/s0378-5955(99)00011-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.