Triedman, John K, Alexander, Mark E, Love, Barry A, Collins, Kathryn K, Berul, Charles I, Bevilacqua, Laura M, Walsh, Edward P·2002·Journal of the American College of Cardiology

Abstract

OBJECTIVES The goal of this study was to identify factors associated with radiofrequency catheter ablation (RFCA) outcomes of intra-atrial re-entrant tachycardia (IART). BACKGROUND Radiofrequency catheter ablation of IART is difficult. The influence of patient and procedural factors and novel technologies on outcomes is unknown. METHODS Acute and chronic RFCA outcomes were studied in patients with congenital heart disease and IART. Clinical status was measured using a multiaxis severity score. Multivariate analyses identified associations of clinical, procedural and technological factors with outcomes. RESULTS A total of 177 procedures were performed in 134 patients; 139 procedures (79%) resulted in RFCA of > or =1 IART circuit and 117 (66%) in RFCA of all targeted circuits. Multivariate analysis associated acute success with irrigated ablation and absence of atrial fibrillation. Twenty-two complications were noted, nine related to vascular access. Electroanatomic mapping failed to decrease procedure or fluoroscopy time. Improvement in clinical status occurred in most patients (severity score preablation: 6.2 +/- 1.6, postablation: 3.0 +/- 2.3, p < 0.0001). At mean follow-up of 25 +/- 11 months, 42% of patients had IART recurrence and 28% required cardioversion. Six deaths occurred (1.8%/patient-year), and two patients underwent transplant. Chronic outcomes were associated with higher right atrial saturations, use of electroanatomic mapping, fewer IART circuits encountered and acute procedural success. CONCLUSIONS Improvement of acute RFCA outcomes was contemporaneous with introduction of novel technologies. Intra-atrial re-entrant tachycardia recurrence was common, and no effect on mortality was discerned, but most patients had effective palliation of symptoms. Chronic outcome predictors included the underlying disease severity, application of novel technologies and successful ablation of all targeted arrhythmia circuits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(02)01858-2

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 260

Metadata

Authors
Triedman, J. K., Alexander, M. E., Love, B. A., Collins, K. K., Berul, C. I., Bevilacqua, L. M., & Walsh, E. P.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2002-06
Volume
39
Issue
11
Pages
1827-1835
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2056575664
Cited by
260
References
24
FWCI
7.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of patient factors and ablative technologies on outcomes of radiofrequency ablation of intra-atrial re-entrant tachycardia in patients with congenital heart disease. https://app.cochat.ai/papers/10.1016/s0735-1097(02)01858-2
The paper
Triedman, J. K., Alexander, M. E., Love, B. A., Collins, K. K., Berul, C. I., Bevilacqua, L. M., & Walsh, E. P. (2002). Influence of patient factors and ablative technologies on outcomes of radiofrequency ablation of intra-atrial re-entrant tachycardia in patients with congenital heart disease. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(02)01858-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.