CoChat

Noncontact three-dimensional mapping and ablation of upper loop re-entry originating in the right atrium

Open access
Tai, Ching-Tai, Huang, Jin-Long, Lin, Yung-Kuo, Hsieh, Ming-Hsiung, Lee, Pi-Chang, Ding, Yu-An, Chang, Mau-Song, Chen, Shih-Ann · 2002 · Journal of the American College of Cardiology
Cited by 87

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study was aimed at delineating the reentrant circuit of right atrial (RA) upper loop re-entry using noncontact three-dimensional mapping. BACKGROUND Various forms of atypical atrial flutter including lower loop re-entry and left atrial flutter have been demonstrated. However, little is known about upper loop re-entry in the RA. METHODS The study population consisted of eight patients (65 +/- 12 years, seven men) with atypical atrial flutter. Right atrial activation during atrial flutter was visualized using a noncontact mapping system (EnSite-3000 with Clarity Software, St. Paul, Minnesota) for a three-dimensional reconstruction of the endocardial depolarization. The narrowest part of the re-entrant circuit was targeted using radiofrequency catheter ablation. RESULTS Noncontact mapping showed macro-re-entry confined to the RA free wall with RA activation time accounting for 100% of the cycle length (214 +/- 21 ms) in all eight patients. Two patients had counterclockwise activation, and six patients had clockwise activation around the central obstacle, which was composed of the crista terminalis, the area of functional block, and superior vena cava. The lower turn-around points were located at the conduction gap in the crista terminalis. Radiofrequency linear ablation of the conduction gap in the crista terminalis was performed and eliminated atrial flutter in six patients without recurrence during a follow-up of 3.2 +/- 1.1 months. CONCLUSIONS Atypical atrial flutter could arise from upper loop re-entry in the RA with conduction through the gap in the crista terminalis. Radiofrequency linear ablation of the conduction gap was effective in eliminating this atrial arrhythmia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(02)02036-3

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 87

Metadata

Authors
Tai, C.-T., Huang, J.-L., Lin, Y.-K., Hsieh, M.-H., Lee, P.-C., Ding, Y.-A., Chang, M.-S., & Chen, S.-A.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2002-08
Volume
40
Issue
4
Pages
746-753
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2069174834
Cited by
87
References
4
FWCI
4.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noncontact three-dimensional mapping and ablation of upper loop re-entry originating in the right atrium. https://app.cochat.ai/papers/10.1016/s0735-1097(02)02036-3
The paper
Tai, C.-T., Huang, J.-L., Lin, Y.-K., Hsieh, M.-H., Lee, P.-C., Ding, Y.-A., Chang, M.-S., & Chen, S.-A. (2002). Noncontact three-dimensional mapping and ablation of upper loop re-entry originating in the right atrium. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(02)02036-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.