Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillation
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES This study was designed to investigate the potential of circumferential pulmonary vein (PV) ablation for atrial fibrillation (AF) to maintain sinus rhythm (SR) over time, thus reducing mortality and morbidity while enhancing quality of life (QoL). BACKGROUND Circumferential PV ablation is safe and effective, but the long-term outcomes and its impact on QoL have not been assessed or compared with those for medical therapy. METHODS We examined the clinical course of 1,171 consecutive patients with symptomatic AF who were referred to us between January 1998 and March 2001. The 589 ablated patients were compared with the 582 who received antiarrhythmic medications for SR control. The QoL of 109 ablated and 102 medically treated patients was measured with the SF-36 survey. RESULTS Median follow-up was 900 days (range 161 to 1,508 days). Kaplan-Meier analysis showed observed survival for ablated patients was longer than among patients treated medically (p < 0.001), and not different from that expected for healthy persons of the same gender and calendar year of birth (p = 0.55). Cox proportional-hazards model revealed in the ablation group hazard ratios of 0.46 (95% confidence interval [CI], 0.31 to 0.68; p < 0.001) for all-cause mortality, of 0.45 (95% CI, 0.31 to 0.64; p < 0.001) for morbidities mainly due to heart failure and ischemic cerebrovascular events, and of 0.30 (95% CI, 0.24 to 0.37; p < 0.001) for AF recurrence. Ablated patients' QoL, different from patients treated medically, reached normative levels at six months and remained unchanged at one year. CONCLUSIONS Pulmonary vein ablation improves mortality, morbidity, and QoL as compared with medical therapy. Our findings pave the way for randomized trials to prospect a wider application of ablation therapy for AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Van Gelder, I. C., Hagens, V. E., Bosker, H. A., Kingma, J. H., Kamp, O., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,359
Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Self-citationThe Italian SF-36 Health Survey
Apolone, G., & Mosconi, P. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00094-8 · Cited by 1,148 · cited 4×
“Separate multivariate models, adjusted for relevant baseline characteristics listed in Figure 3, were used to assess changes in SF-36 physical and mental summary component scores, and the independent relationship of treatment and AF recurrence with QoL.”
MethodInfluentialAmiodarone to Prevent Recurrence of Atrial Fibrillation
Roy, D., Talajic, M., Dorian, P., Connolly, S., Eisenberg, M. J., Green, M., Kus, T., Lambert, J., Dubuc, M., Gagné, P., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003303421302 · Cited by 1,143
Hohnloser, S. H., Kuck, K.-H., & Lilienthal, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03230-x · Cited by 1,134
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112 · cited 1×
“This may explain why the success rates of this ablative technique in both arrhythmia types are higher than in mapping-guided strategies isolating PVs at their ostia, without excluding any atrial myocardium (14).”
ResultPappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863 · cited 5×
“This purely anatomic approach yields either an atriovenous electrical disconnection, as demonstrated by elimination of PV ostial potentials and absence of discrete electrical activity inside the lesion during pacing outside the ablation line, or a profound atrial electroanatomic remodeling, as expressed by voltage aba…”
BackgroundMethodInfluentialSelf-citation
Cited by
Items 801–840 of 840
Zhang, B., Han, J., Zhou, D., Jiang, J., Zhong, J., Lu, Y., Zuo, C., Lu, X., Xuan, J., Zu, A., et al. (2024) · PubMed Central · doi:10.57264/cer-2023-0035
Wang, Z., Lei, N., Zhang, Y., Tong, Q., Sun, Y., Cai, J., Xu, Q., Mahamoud, O. A., Liu, X., Zhao, Q., et al. (2024) · Research Square · doi:10.21203/rs.3.rs-4002924/v1
PAPER: RECENT DEVELOPMENTS IN THE MANAGEMENT OF ATRIAL FIBRILLATION
Hutcheon, S., & Broadhurst, P. (2004) · The Journal of the Royal College of Physicians of Edinburgh · doi:10.1177/1478271520043404003
L'ablation par cathéter de la fibrillation auriculaire
Brabandt, H. V., Neyt, M., & Devos, C. (2012) · doi:10.57598/r184b
Bidaoui, G., Feng, H., Chouman, N., Assaf, A. Y. M., Lim, C., Younes, H., Bsoul, M., Massad, C. M., Polo, F. T., Jia, Y., et al. (2025) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-025-02002-1
“Catheter ablation (CA) of AF is associated with more improvements in QoL compared to other treatment modalities [7, 8].”
Holt, A., & Laver, R. D. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-11611-7.00031-1
Calvo, N. (2013) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona)
Clarkesmith, D. (2012) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00019238
Stellenwert der Katheterablation bei paroxysmalem und persistierendem/permanentem Vorhofflimmern
Gonska, B. (2007) · Clinical Research in Cardiology Supplements · doi:10.1007/s11789-007-0013-9
Quality of Life in Patients with Cardiac Rhythm Disturbances
Bacior, B., & Styczkiewicz, K. (2012) · Springer eBooks · doi:10.1007/978-88-470-2769-5_6
HEART's Original [症例] 電気的除細動と肺静脈隔離術により洞調律を維持し心機能が著明に改善した心房細動による頻脈誘発性心筋症の1例
有川, 亮., 二宮, 雄., 八反田和美, 石田, 実., 桶谷, 直., 仁志, 市., 奥井, 英., 片岡哲郎, 植屋, 奈., 平川立身, et al. (2007) · 心臓 · doi:10.11281/shinzo1969.39.10_902
Lebensqualität bei Patienten mit Vorhofflimmern
Micus, S., & Justus Liebig University Giessen (2004) · University writing server of the Justus Liebig University Giessen (Justus-Liebig-Universität Gießen) · doi:10.22029/jlupub-12857
Editorial: Katheterablation bei Vorhofflimmern - in welche Richtung wird das Pendel schwingen?
Fx, R., & Hintringer, F. (2005) · Journal für Kardiologie (Krause & Pachernegg GmbH)
Olivier, A. (2012) · Publications Et Travaux Academiques de Lorraine (Universite de Lorraine)
Saad, E. B. (2011) · Americanae (AECID Library)
高周波カテーテルアブレーション治療を施行した心房細動患者における可溶性トロンポモジュリンと循環miRNAの動態
波野史典, & Namino, F. (2019) · Kagoshima University Repository
Audiences’ willingness to participate in Welsh‐language media
Hunter, R. J. (2013) · Queen Mary Research Online (Queen Mary University of London)
Parollo, M. (2017) · Electronic Theses and Dissertations Repository (University of Pisa)
ORIENTE, D. (2014) · Electronic Theses and Dissertations Repository (University of Pisa)
Целесообразность поддержания синусового ритма у больных с фибрилляцией предсердий
Канорский, С. Г., & Kruchinova, O. A. (2006) · The scientific electronic library of periodicals of the National Academy of Sciences of Ukraine (National Academy of Sciences of Ukraine)
Ablation par radiofréquence de la fibrillation atriale (l'expérience de Nancy)
SAMET, H., & Aliot, E. (2005) · Publications Et Travaux Academiques de Lorraine (Universite de Lorraine)
Atrial Fibrillation Ablation: History, Practice, and Innovation
(2016) · Arizona State University Library Digital Repository (Arizona State University)
(n.d.) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
BARTOLI, L. (2017) · Electronic Theses and Dissertations Repository (University of Pisa)
Atrial fibrillation and the pulmonary veins
Gottlieb, L. A. (2022) · Pure Amsterdam UMC
Selbach, S. M. (2009) · bonndoc (University of Bonn)
Fan, Y., Ye, J., Wang, X., Song, L., & Wang, P. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1697542
Galperín, J. (2026) · Revista Argentina de Cardiología · doi:10.7775/rac.v71i5.2875
Peliche, F., Borracci, R. A., Ferreirós, E., Boissonnet, C. P., Fuselli, J. J., Guetta, J. N., Toro, D. D., Cragnolino, R., Kevorkián, R., Ciruzzi, M. A., et al. (2026) · Revista Argentina de Cardiología · doi:10.7775/rac.v72i1.2842
心臓超音波組織ドプラーを用いた心房リモデリングの評価と心房細動アブレーション後の再発の予知
園田和正 (2015) · Institutional Repositories DataBase (IRDB) · doi:10.15006/32665a4906
心房細動に対するクライオバルーンアブレーションを用いた永続性のある肺静脈隔離を作成するための指標に関する臨床的検討
Watanabe, T. (2020) · Institutional Repositories DataBase (IRDB) · doi:10.15006/32665a5591
Katov, L., Ballweg, J., Teumer, Y., Rostan, J., Diofano, F., Bothner, C., Rottbauer, W., & Weinmann, K. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15197654
Chen, X., Jiangtao Zhao, Kui Zhu, Fen Qin, and, H. L., & Tao, H. (2021) · doi:10.3389/fcvm.2021.756552.s001
Workplace projects: Recurrent Event Survival Analysis Models for Assessing Factors
O'Loughlin, A. J. (2006) · The Sydney eScholarship Repository (The University of Sydney)
Torrent, M. J. G. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Klassifikationen, Erkrankungsverläufe und Symptomatologie
CARLSSON, J., NEUZNER, J., & Erdogan, A. R. (2007) · Steinkopff eBooks · doi:10.1007/978-3-7985-1748-6_3
Pulmonary Veins and Cardiac Veins
Greco, M. D., Ravelli, F., & Marini, M. (2012) · Springer eBooks · doi:10.1007/978-88-470-2522-6_9
Importance of Left Atrial Imaging in Catheter Ablation of Atrial Fibrillation
Oh, S., Cho, Y., & Choi, E. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5316-0_32
New frontiers in atrial fibrillation
Saksena, S. V. (2006) · Steinkopff eBooks · doi:10.1007/3-7985-1632-4_14
Metadata
- Authors
- Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., Tortoriello, V., Sala, S., Zangrillo, A., Crescenzi, G., Benussi, S., & Alfieri, O.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 42
- Issue
- 2
- Pages
- 185-197
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2572139654
- Cited by
- 781
- References
- 21
- FWCI
- 51.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.