Left ventricular filling in dilated cardiomyopathy: Relation to functional class and memodynamics
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Left ventricular systolic function does not correlate well with functional class in patients with dilated cardiomyopathy. To determine whether the correlation is better with Doppler indexes of left ventricular diastolic function, 34 patients with dilated cardiomyopathy (M-mode echocardiographic end-diastolic dimension greater than 60 mm, fractional shortening less than 25%, increased E point-septal separation) were studied. Patients were classified into two groups according to functional class. Group 1 consisted of 16 patients in New York Heart Association functional class I or II; group 2 included 18 patients in functional class III or IV. Left ventricular dimensions, fractional shortening, left ventricular mass, meridional end-systolic wall stress, peak early and late transmitral filling velocities and their ratio, isovolumetric relaxation period and time to peak filling rate were computed from pulsed wave Doppler and M-mode echocardiograms and calibrated carotid pulse tracings. Right heart catheterization was performed in 20 of 34 patients. No differences were observed between groups with regard to age, gender distribution, heart rate, blood pressure and M-mode echocardiographic-derived indexes of systolic function. Peak early filling velocity (72 +/- 13 versus 40 +/- 10 cm/s, p less than 0.001) was higher and atrial filling fraction (27 +/- 4% versus 46 +/- 8%, p less than 0.001) was lower in group 2 than in group 1. The ratio of early to late transmitral filling velocities was higher in group 2 patients (2.3 +/- 0.5 versus 0.7 +/- 0.2, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.
Devereux, R. B., & Reichek, N. (1977) · Circulation · doi:10.1161/01.cir.55.4.613 · Cited by 4,485
Wall stress and patterns of hypertrophy in the human left ventricle.
Grossman, W., Jones, D., & McLaurin, L. P. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108079 · Cited by 2,403
Appleton, C. P., Hatle, L. K., & Popp, R. L. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90416-0 · Cited by 1,568
Currie, P. J., Seward, J. B., Chan, K.-L., Fyfe, D. A., Hagler, D. J., Mair, D. D., Reeder, G. S., Nishimura, R. A., & Tajik, A. J. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80477-0 · Cited by 1,002
Preload dependence of doppler-derived indexes of left ventricular diastolic function in humans
Choong, C. Y., Herrmann, H. C., Weyman, A. E., & Fifer, M. A. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80273-5 · Cited by 624
Congestive heart failure with normal systolic function
Dougherty, A. H., Naccarelli, G. V., Gray, E. L., Hicks, C. H., & Goldstein, R. A. (1984) · The American Journal of Cardiology · doi:10.1016/s0002-9149(84)80207-6 · Cited by 616
Rokey, R., Kuo, L. C., Zoghbi, W. A., Limacher, M. C., & Quinones, M. A. (1985) · Circulation · doi:10.1161/01.cir.71.3.543 · Cited by 530
Spirito, P., Maron, B. J., & Bonow, R. O. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80461-2 · Cited by 421
Cardiopulmonary exercise testing for evaluation of chronic cardiac failure
Weber, K. T., & Janicki, J. S. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90792-1 · Cited by 374
Keren, G., Sherez, J., Megidish, R., Levitt, B., & Laniado, S. (1985) · Circulation · doi:10.1161/01.cir.71.6.1105 · Cited by 296
Labovitz, A. J., & Pearson, A. C. (1987) · American Heart Journal · doi:10.1016/0002-8703(87)90795-2 · Cited by 282
Functional capacity of patients with chronic left ventricular failure
Franciosa, J. A., Ziesche, S., & Mary Wilen, R. N. (1979) · The American Journal of Medicine · doi:10.1016/0002-9343(79)90794-0 · Cited by 262
Keren, G., Sonnenblick, E. H., & LeJemtel, T. H. (1988) · Circulation · doi:10.1161/01.cir.78.3.621 · Cited by 236
Doppler mitral pressure half-time: A clinical tool in search of theoretical justification
Thomas, J. D., & Weyman, A. E. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80290-5 · Cited by 176
Atrial contraction is an important determinant of pulmonary venous flow
Keren, G., Bier, A. J., Sherez, J., Miura, D. S., Keefe, D. L., & LeJemtel, T. H. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80482-x · Cited by 116
Colan, S. D., Borow, K. M., & Neumann, A. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90356-4 · Cited by 74
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
New Doppler echocardiographic applications for the study of diastolic function
Garcia, M. J., Thomas, J. D., & Klein, A. L. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00345-3 · Cited by 991
Metadata
- Authors
- Vanoverschelde, J.-L. J., Raphael, D. A., Robert, A. R., & Cosyns, J. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1990-05
- Volume
- 15
- Issue
- 6
- Pages
- 1288-1295
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2086600559
- Cited by
- 290
- References
- 17
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.