Subject‐specific finite element analysis of the human medial collateral ligament during valgus knee loading
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The objectives of this study were (1) to develop subject‐specific experimental and finite element (FE) techniques to study the three‐dimensional stress–strain behavior of ligaments, with application to the human medial collateral ligament (MCL), and (2) to determine the importance of subject‐specific material properties and initial (in situ) strain distribution for prediction of the strain distribution in the MCL under valgus loading. Eight male knees were subjected to varus–valgus loading at flexion angles of 0°, 30°, and 60°. Three‐dimensional joint kinematics and MCL strains were recorded during kinematic testing. Following testing, the MCL of each knee was removed to allow measurement of the in situ strain distribution and to perform material testing. A FE model of the femur–MCL–tibia complex was constructed for each knee to simulate valgus loading at each flexion angle, using subject‐specific bone and ligament geometry, material properties, and joint kinematics. A transversely isotropic hyperelastic material model was used to represent the MCL. The MCL in situ strain distribution at full extension was used to apply in situ strain to each MCL FE model. FE predicted MCL strains during valgus loading were compared to experimental measurements using regression analysis. The subject‐specific FE predictions of strain correlated reasonably well with experimentally measured MCL strains (R2 = 0.83, 0.72, and 0.66 at 0°, 30°, and 60°, respectively). Despite large inter‐subject variation in MCL material properties, MCL strain distributions predicted by individual FE models that used average MCL material properties were strongly correlated with subject‐specific FE strain predictions (R2 = 0.99 at all flexion angles). However, predictions by FE models that used average in situ strain distributions yielded relatively poor correlations with subject‐specific FE predictions (R2 = 0.44, 0.35, and 0.33 at flexion angles of 0°, 30°, and 60°, respectively). The strain distribution within the MCL was nonuniform and changed with flexion angle. The highest MCL strains occurred at full extension in the posterior region of the MCL proximal to the joint line during valgus loading, suggesting this region may be most vulnerable to injury under these loading conditions. This work demonstrates that subject‐specific FE models can predict the complex, nonuniform strain fields that occur in ligaments due to external loading of the joint. © 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104 · cited 1×
“Polygonal surfaces of the femur and tibia were extracted using marching cubes [24] with decimation [36] (Fig.”
MethodMarching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805 · cited 1×
“Embedded coordinate systems were established for the femur and tibia as defined by the Grood–Suntay convention [14] by digitizing anatomical points with the ISL via the method of Kirstukas et al. [20] [21].”
MethodSchroeder, W. J., Zarge, J. A., & Lorensen, W. E. (1992) · Proceedings of the 19th annual conference on Computer graphics and interactive techniques · doi:10.1145/133994.134010 · Cited by 1,464 · cited 1×
“Polygonal surfaces of the femur and tibia were extracted using marching cubes [24] with decimation [36] (Fig.”
MethodMarkolf, K., Mensch, J., & Amstutz, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658050-00001 · Cited by 844 · cited 1×
“This is in agreement with the results of other studies [13,27,37,40].”
ResultFinite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797 · cited 1×
“The MCL was represented as transversely isotropic hyperelastic with the following strain energy W [42] Here ~ I I 1 is the first deviatoric invariant, ~ k k is the deviatoric part of the stretch ratio along the local fiber direction, and J is the determinant of the deformation gradient, F.”
BackgroundSelf-citationThe incidece of knee ligament injuries in the general population
Miyasaka, K. (1991) · Medical Entomology and Zoology · Cited by 626
Grood, E. S., Noyes, F. R., Butler, D. L., & Suntay, W. J. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163080-00007 · Cited by 546 · cited 1×
“The femur–MCL– tibia complex of the human knee was chosen for study because of the high incidence of MCL injuries [31] and the clinical importance of interactions between the MCL and the anterior cruciate ligament in restraining valgus rotations and anterior–posterior translations [13] [37].”
MethodThe solution of nonlinear finite element equations
Matthies, H., & Strang, G. (1979) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620141104 · Cited by 511 · cited 1×
“An automatic timestepping strategy was employed, with iterations based on a quasiNewton method [28] and convergence based on the L2 displacement norm [25,28].”
MethodON THE SOLUTION OF NONLINEAR FINITE ELEMENT EQUATIONS.
Bathe, K., Dvorkin, E. N., & Kojić, M. (1984) · Cited by 430
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Subject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Verification, validation and sensitivity studies in computational biomechanics
Anderson, A. E., Ellis, B. J., & Weiss, J. A. (2007) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840601160484 · Cited by 237
Self-citationRole of the acetabular labrum in load support across the hip joint
Henak, C. R., Ellis, B. J., Harris, M. D., Anderson, A. E., Peters, C. L., & Weiss, J. A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.011 · Cited by 209
“Many fiber-reinforced soft tissues are subjected to in situ stress (e.g., Gardiner and Weiss, 2003), which results in a stiffer material response for a given applied load.”
Self-citationA ‘Plane’ Explanation of Anterior Cruciate Ligament Injury Mechanisms: A Systematic Review
Quatman, C. E., Quatman-Yates, C. C., & Hewett, T. E. (2010) · Sports Medicine · doi:10.2165/11534950-000000000-00000 · Cited by 209
Validation of computational models in biomechanics
Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim649 · Cited by 204
Self-citationGauging force by tapping tendons
Martin, J. A., Brandon, S. C. E., Keuler, E. M., Hermus, J. R., Ehlers, A. C., Segalman, D. J., Allen, M. S., & Thelen, D. G. (2018) · Nature Communications · doi:10.1038/s41467-018-03797-6 · Cited by 186
Finite element modeling of soft tissues: Material models, tissue interaction and challenges
Freutel, M., Schmidt, H., Dürselen, L., Ignatius, A., & Galbusera, F. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.01.006 · Cited by 184
“It is important to distinguish if the validation experiments were conducted on the same specimen used as a reference to build the model or if they are averaged results of a number of specimens, since this influences the accuracy of the validation (Gardiner and Weiss, 2003).”
Orsi, A. D., Chakravarthy, S., Canavan, P. K., Peña, E., Goebel, R., Vaziri, A., & Nayeb-Hashemi, H. (2016) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2015.1043626 · Cited by 24
“These studies also described a deceleration closed chain mechanism associated with ACL injury.”
Metadata
- Authors
- Gardiner, J. C., & Weiss, J. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 21
- Issue
- 6
- Pages
- 1098-1106
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2171016154
- Cited by
- 238
- References
- 36
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.