Subject‐specific finite element analysis of the human medial collateral ligament during valgus knee loading
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The objectives of this study were (1) to develop subject‐specific experimental and finite element (FE) techniques to study the three‐dimensional stress–strain behavior of ligaments, with application to the human medial collateral ligament (MCL), and (2) to determine the importance of subject‐specific material properties and initial (in situ) strain distribution for prediction of the strain distribution in the MCL under valgus loading. Eight male knees were subjected to varus–valgus loading at flexion angles of 0°, 30°, and 60°. Three‐dimensional joint kinematics and MCL strains were recorded during kinematic testing. Following testing, the MCL of each knee was removed to allow measurement of the in situ strain distribution and to perform material testing. A FE model of the femur–MCL–tibia complex was constructed for each knee to simulate valgus loading at each flexion angle, using subject‐specific bone and ligament geometry, material properties, and joint kinematics. A transversely isotropic hyperelastic material model was used to represent the MCL. The MCL in situ strain distribution at full extension was used to apply in situ strain to each MCL FE model. FE predicted MCL strains during valgus loading were compared to experimental measurements using regression analysis. The subject‐specific FE predictions of strain correlated reasonably well with experimentally measured MCL strains (R2 = 0.83, 0.72, and 0.66 at 0°, 30°, and 60°, respectively). Despite large inter‐subject variation in MCL material properties, MCL strain distributions predicted by individual FE models that used average MCL material properties were strongly correlated with subject‐specific FE strain predictions (R2 = 0.99 at all flexion angles). However, predictions by FE models that used average in situ strain distributions yielded relatively poor correlations with subject‐specific FE predictions (R2 = 0.44, 0.35, and 0.33 at flexion angles of 0°, 30°, and 60°, respectively). The strain distribution within the MCL was nonuniform and changed with flexion angle. The highest MCL strains occurred at full extension in the posterior region of the MCL proximal to the joint line during valgus loading, suggesting this region may be most vulnerable to injury under these loading conditions. This work demonstrates that subject‐specific FE models can predict the complex, nonuniform strain fields that occur in ligaments due to external loading of the joint. © 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104 · cited 1×
“Polygonal surfaces of the femur and tibia were extracted using marching cubes [24] with decimation [36] (Fig.”
MethodMarching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805 · cited 1×
“Embedded coordinate systems were established for the femur and tibia as defined by the Grood–Suntay convention [14] by digitizing anatomical points with the ISL via the method of Kirstukas et al. [20] [21].”
MethodSchroeder, W. J., Zarge, J. A., & Lorensen, W. E. (1992) · Proceedings of the 19th annual conference on Computer graphics and interactive techniques · doi:10.1145/133994.134010 · Cited by 1,464 · cited 1×
“Polygonal surfaces of the femur and tibia were extracted using marching cubes [24] with decimation [36] (Fig.”
MethodMarkolf, K., Mensch, J., & Amstutz, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658050-00001 · Cited by 844 · cited 1×
“This is in agreement with the results of other studies [13,27,37,40].”
ResultFinite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797 · cited 1×
“The MCL was represented as transversely isotropic hyperelastic with the following strain energy W [42] Here ~ I I 1 is the first deviatoric invariant, ~ k k is the deviatoric part of the stretch ratio along the local fiber direction, and J is the determinant of the deformation gradient, F.”
BackgroundSelf-citationThe incidece of knee ligament injuries in the general population
Miyasaka, K. (1991) · Medical Entomology and Zoology · Cited by 626
Grood, E. S., Noyes, F. R., Butler, D. L., & Suntay, W. J. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163080-00007 · Cited by 546 · cited 1×
“The femur–MCL– tibia complex of the human knee was chosen for study because of the high incidence of MCL injuries [31] and the clinical importance of interactions between the MCL and the anterior cruciate ligament in restraining valgus rotations and anterior–posterior translations [13] [37].”
MethodThe solution of nonlinear finite element equations
Matthies, H., & Strang, G. (1979) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620141104 · Cited by 511 · cited 1×
“An automatic timestepping strategy was employed, with iterations based on a quasiNewton method [28] and convergence based on the L2 displacement norm [25,28].”
MethodON THE SOLUTION OF NONLINEAR FINITE ELEMENT EQUATIONS.
Bathe, K., Dvorkin, E. N., & Kojić, M. (1984) · Cited by 430
Whirley, R. G., & Engelmann, B. E. (1993) · doi:10.2172/10139227 · Cited by 395
Material Characterization of Human Medial Collateral Ligament
Quapp, K. M., & Weiss, J. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834890 · Cited by 351 · cited 3×
“Uniaxial tensile test specimens were harvested from the MCL parallel and transverse to the collagen fiber direction with hardened steel dogbone-shaped punches using an established protocol [34].”
BackgroundMethodInfluentialSelf-citationA three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351 · cited 2×
“This entails using either single or multiple line elements [ 46 ], while allowing load transfer to bones at single or multiple points [5].”
BackgroundMethodThe prime static stabilizer of the medical side of the knee.
Warren, L. E., Marshall, J. S., & Girgis, F. G. (1974) · PubMed · Cited by 285
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285 · cited 1×
“The method of material characterization used in this study prohibits quantifying material properties throughout the entire MCL because of the needed sample sizes, but histological [32] or optical [15] measurements could be utilized to estimate material properties on a regional basis.”
MethodSelf-citationThe Prime Static Stabilizer of the Medial Side of the Knee
WARREN, L. F., MARSHALL, J. L., & GIRGIS, F. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456040-00002 · Cited by 278 · cited 1×
“This is in agreement with the results of other studies [13,27,37,40].”
ResultLigament-Bone Interaction in a Three-Dimensional Model of the Knee
Blankevoort, L., & Huiskes, R. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894883 · Cited by 267 · cited 1×
“This entails using either single or multiple line elements [46], while allowing load transfer to bones at single or multiple points [ 5 ].”
BackgroundA Validated Three-Dimensional Computational Model of a Human Knee Joint
Li, G., Gil, J., Kanamori, A., & Woo, S. L.-Y. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800871 · Cited by 264 · cited 1×
“This approach has proved useful for predicting joint kinematics under the application of external loads (e.g., [23]), but it possesses several significant shortcomings: (1) nonuniform, 3D stresses and strains cannot be predicted, and (2) multiple sets of parameters and initial tensions routinely…”
BackgroundWalker, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)90000-4 · Cited by 250
Finite element analysis of human knee joint in varus-valgus
Bendjaballah, M., Shirazi-Adl, A., & Zukor, D. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00072-7 · Cited by 241 · cited 2×
“The use of computational methods for the study of joint mechanics can elucidate ligament function and yield information that is difficult or impossible to obtain experimentally [2] [3] [9] [16] [17].”
BackgroundStrain in the anteromedial bundle of the anterior cruciate ligament under combination loading
Berns, G. S., Hull, M. L., & Patterson, H. A. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100203 · Cited by 219 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundLigament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
Weiss, J. A., Gardiner, J. C., & Bonifasi-Lista, C. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00041-6 · Cited by 210 · cited 1×
“The response of the strain energy function used in this study may be too stiff under shear loading as evidenced by large deformation simple shear loading of MCL samples [41].”
MethodSelf-citationDirect Linear Transformation Method for Three-Dimensional Cinematography
Shapiro, R. (1978) · Research Quarterly. American Alliance for Health, Physical Education and Recreation · doi:10.1080/10671315.1978.10615524 · Cited by 201 · cited 1×
“The marker tracking system was calibrated over a 350 cm 3 volume using the direct linear transformation method [38], allowing the 3D coordinates of the markers to be tracked to within ±0.1 mm during all testing [10].”
MethodInfluentialCellular shape and pressure may mediate mechanical control of tissue composition in tendons
Giori, N. J., Beaupré, G. S., & Carter, D. R. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110413 · Cited by 190 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundThe biomechanics of the human patella during passive knee flexion
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00059-q · Cited by 180 · cited 1×
“The use of computational methods for the study of joint mechanics can elucidate ligament function and yield information that is difficult or impossible to obtain experimentally [2] [3] [9] [16] [17].”
BackgroundStrain in the Human Medial Collateral Ligament During Valgus Loading of the Knee
Gardiner, J. C., Weiss, J. A., & Rosenberg, T. D. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200110000-00031 · Cited by 167 · cited 3×
“The marker tracking system was calibrated over a 350 cm 3 volume using the direct linear transformation method [38], allowing the 3D coordinates of the markers to be tracked to within ±0.1 mm during all testing [10].”
BackgroundMethodInfluentialSelf-citationThe function of the primary ligaments of the knee in varus-valgus and axial rotation
Seering, W. P., Piziali, R. L., Nagel, D. A., & Schurman, D. J. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90240-7 · Cited by 166 · cited 1×
“The femur–MCL– tibia complex of the human knee was chosen for study because of the high incidence of MCL injuries [31] and the clinical importance of interactions between the MCL and the anterior cruciate ligament in restraining valgus rotations and anterior–posterior translations [13] [37].”
MethodStress governs tissue phenotype at the femoral insertion of the rabbit MCL
Matyas, J. R., Anton, M. G., Shrive, N. G., & Frank, C. B. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00058-c · Cited by 130 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundHIROKAWA, S., & Tsuruno, R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00073-7 · Cited by 121 · cited 2×
“The use of computational methods for the study of joint mechanics can elucidate ligament function and yield information that is difficult or impossible to obtain experimentally [2] [3] [9] [16] [17].”
BackgroundRobins, A. J., Newman, A., & Burks, R. T. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100104 · Cited by 115 · cited 1×
“Injuries in this area generally do not heal as well as those located distal to the joint line [35].”
BackgroundStrain in the medial collateral ligament of the human knee under single and combined loads
Hull, M. L., Berns, G. S., Varma, H., & Patterson, H. A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00046-1 · Cited by 102 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundStrain measurement in the medial collateral ligament of the human knee: An autopsy study
Arms, S. W., Boyle, J., Johnson, R. J., & Pope, M. H. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90063-5 · Cited by 102 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundMedial collateral ligament injuries of the knee: ultrasonographic findings.
Lee, J. I., Song, I. S., Jung, Y. B., et al. (1996) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1996.15.9.621 · Cited by 77 · cited 1×
“Clinical injury patterns also confirm that the posterior proximal region of the MCL is the most common injury location [19,22].”
BackgroundNonuniform distribution of collagen density in human knee ligaments
Mommersteeg, T. J. A., Blankevoort, L., Kooloos, R. J. G. M., Hendriks, J. C. M., Kauer, J. M. G., & Huiskes, R. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120213 · Cited by 38 · cited 2×
“Further improvements in modeling accuracy could be achieved by including inhomogeneities in MCL material properties that likely occur throughout the ligament substance [32].”
BackgroundMethodKawada, T., Abe, T., Yamamoto, K. L., HIROKAWA, S., Soejima, T., Tanaka, N., & Inoue, A. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00051-x · Cited by 29 · cited 1×
“Ligaments are subjected to highly nonuniform deformations in vivo that result from a combination of tension , shear, bending, and compression [11] [29], and the regional contribution of a ligament to joint stability changes with joint orientation [1] [4] [10] [18] [19] [47].”
BackgroundLab., C. (. S. L. L. N., Maker, B. N., & USDOE, W. (1995) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/110704 · Cited by 17
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Subject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Verification, validation and sensitivity studies in computational biomechanics
Anderson, A. E., Ellis, B. J., & Weiss, J. A. (2007) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840601160484 · Cited by 237
Self-citationRole of the acetabular labrum in load support across the hip joint
Henak, C. R., Ellis, B. J., Harris, M. D., Anderson, A. E., Peters, C. L., & Weiss, J. A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.011 · Cited by 209
“Many fiber-reinforced soft tissues are subjected to in situ stress (e.g., Gardiner and Weiss, 2003), which results in a stiffer material response for a given applied load.”
Self-citationA ‘Plane’ Explanation of Anterior Cruciate Ligament Injury Mechanisms: A Systematic Review
Quatman, C. E., Quatman-Yates, C. C., & Hewett, T. E. (2010) · Sports Medicine · doi:10.2165/11534950-000000000-00000 · Cited by 209
Metadata
- Authors
- Gardiner, J. C., & Weiss, J. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 21
- Issue
- 6
- Pages
- 1098-1106
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2171016154
- Cited by
- 238
- References
- 36
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.