The DOI matches its Crossref record; 80 of the 81 references it cites were found in a registry or an index.
Complications of invasive monitoring
Abstract
Invasive monitoring in anesthesiology is relatively safe. Arterial catheterization in particular has an extremely low rate of serious complications. Radial, brachial, and femoral artery catheterization sites appear to have similar and low complication rates. CVP and PA catheters are more dangerous and entail potentially fatal complications. The most troublesome complication with CVP catheters is perforation of the heart or cava, which should be avoidable under most circumstances if care is taken to position the catheter properly, outside the heart. Chest radiography should be used to specifically ascertain that the catheter is not in a dangerous location. The most troublesome complication with PA catheters is perforation of the pulmonary artery. This is probably a sporadic problem, and it is not necessarily avoidable by adherence to particular techniques. It should be assumed that hemoptysis in a patient with a PA catheter is caused by perforation of the pulmonary artery until proven otherwise, and it should be treated aggressively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, continuous monitoring of certain vital signs, such as blood pressure, demands additional wired hardware, such as peripheral and umbilical arterial catheters4, which can induce other types of complications, including thrombus formation and occlusion, infection (e.g. sepsis), rupture, pseudoaneurysm, bleeding, and death5–7.”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [4]
In the citing paper
“Episodic measurements of BP in current clinical practice on neonates and pediatric patients involve miniaturized, but otherwise conventional, BP cuffs that wrap around the limbs, while continuous tracking requires catheter-based pressure sensors (arterial lines) that insert into peripheral arteries. Both procedures, particularly the latter, are invasive and involve multiple risk factors4”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [4]
Citations
Cites
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA · doi:10.1001/jama.276.11.889 · Cited by 2,431
Ultrasound guidance for placement of central venous catheters
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 850
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L. (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 536
Infectious Complications of Indwelling Vascular Catheters
RAAD, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 450
Allen, E. V. (1929) · The American Journal of the Medical Sciences · doi:10.1097/00000441-192908000-00009 · Cited by 417
Is It Time to Pull the Pulmonary Artery Catheter?
Dalen, J. E. (1996) · JAMA · doi:10.1001/jama.1996.03540110070035 · Cited by 402
On the Safety of Radial Artery Cannulation
Slogoff, S., Keats, A. S., & Arlund, C. (1983) · Anesthesiology · doi:10.1097/00000542-198307000-00008 · Cited by 361
The American Society of Anesthesiologists Closed Claims Project
Cheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199908000-00030 · Cited by 332
Ultrasound-Guided Cannulation of the Internal Jugular Vein. A Prospective, Randomized Study
Troianos, C. A., Jobes, D. R., & Ellison, N. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199106000-00020 · Cited by 317
A Review of Pulmonary Artery Catheterization in 6,245 Patients
Shah, K., Rao, T. L. K., Laughlin, S., & El-Etr, A. A. (1984) · Anesthesiology · doi:10.1097/00000542-198409000-00007 · Cited by 300
Research works printed but not linked: 2
- Welliver, 2001, Thoracic duct cannulation during central venous catheterization: a case report, Am J Anesthesiol, 28, 199
- Bowdle, 1996, Complications from placement of central venous catheters: importance of the chest x-ray, American Society of Anesthesiologists Newletter, 60, 22
Cited by
Sorted by citations
Harvey, S. E., Harrison, D. A., Singer, M., Ashcroft, J., Jones, C., Elbourne, D. R., Brampton, W., Williams, D., Young, D., & Rowan, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67061-4 · Cited by 1,115
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Gore, J. M., Goldberg, R. J., Spodick, D. H., Alpert, J. S., & Dalen, J. E. (1987) · CHEST Journal · doi:10.1378/chest.92.4.721 · Cited by 403
Lack of Equivalence Between Central and Mixed Venous Oxygen Saturation
Chawla, L. S., Zia, H., Gutiérrez, G., Katz, N. M., Seneff, M. G., & Shah, M. (2004) · CHEST Journal · doi:10.1378/chest.126.6.1891 · Cited by 197
Biais, M., Nouette-Gaulain, K., Cottenceau, V., Alain, V., Cochard, J.-F., Revel, P., & François, S. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b309 · Cited by 187
Button, D., Weibel, L., Reuthebuch, O. T., Genoni, M., Zollinger, A., & Hofer, C. K. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem188 · Cited by 173
Binns, S. H., Sisson, D. D., Buoscio, D. A., & Schaeffer, D. J. (1995) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.1995.tb03301.x · Cited by 166
Min, S., An, J., Lee, J. H., Kim, J. H., Joe, D. J., Eom, S. H., Yoo, C. D., Ahn, H., Hwang, J.-Y., Xu, S. H., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01127-0 · Cited by 138
Perioperative management and monitoring in anaesthesia
Bühre, W., & Rossaint, R. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14905-7 · Cited by 121
Long term, implantable blood pressure monitoring systems
Potkay, J. A. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9146-3 · Cited by 113
Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station
Causey, M. W., Miller, S., Foster, A., Beekley, A. C., Zenger, D., & Martin, M. J. (2011) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2011.01.020 · Cited by 111
The Accuracy of Electrocardiogram-Controlled Central Line Placement
Gebhard, R. E., Szmuk, P., Pivalizza, E. G., Melnikov, V., Vogt, C., & Warters, R. D. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000250224.02440.fe · Cited by 109
Laparoscopic surgery: Pitfalls due to anesthesia, positioning, and pneumoperitoneum
Henny, C. P., & Hofland, J. (2005) · Surgical Endoscopy · doi:10.1007/s00464-004-2250-z · Cited by 104
A review on B-type natriuretic peptide monitoring: assays and biosensors
Maalouf, R., & Bailey, S. R. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9544-9 · Cited by 82
Harvey, S. E., Stevens, K. J., Harrison, D. A., Young, D., Brampton, W., McCabe, C. J., Singer, M., & Rowan, K. (2006) · Health Technology Assessment · doi:10.3310/hta10290 · Cited by 79
Waldron, N. H., Miller, T. E., Thacker, J. K. M., Manchester, A. K., White, W. D., Nardiello, J., Elgasim, M. A., Moon, R. E., & Gan, T. J. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000182 · Cited by 76
Ultrasound detection of guidewire position during central venous catheterization
Stone, M. B., Nagdev, A. D., Murphy, M. C., & Sisson, C. A. (2009) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.09.019 · Cited by 57
Congenital Anomalies of Superior Vena Cava and their Implications in Central Venous Catheterization
Rossi, U. G., Rigamonti, P., Torcia, P., Mauri, G., Brunini, F., Rossi, M., Gallieni, M. A., & Cariati, M. (2015) · The Journal of Vascular Access · doi:10.5301/jva.5000371 · Cited by 39
Persistent Left Superior Vena Cava: An Incidental Finding During Central Venous Catheterization
Danielpour, P. J., Aalberg, J. K., El-Ramey, M., Sivina, M., & Wodnicki, H. (2005) · Vascular and Endovascular Surgery · doi:10.1177/153857440503900111 · Cited by 39
Aslan, N., Yıldızdaş, D., Horoz, Ö. Ö., Çoban, Y., Demir, F., Erdem, S., & Sertdemır, Y. (2020) · The Italian Journal of Pediatrics/Italian journal of pediatrics · doi:10.1186/s13052-020-0803-y · Cited by 30
Hager, H., Mandadi, G., Pulley, D. D., Eagon, J. C., Mascha, E. J., Nutter, B., & Kurz, A. M. (2008) · Obesity Surgery · doi:10.1007/s11695-008-9607-7 · Cited by 31
Wrist Hyperextension Leads to Median Nerve Conduction Block
Chowet, A. L., López, J. R., Brock‐Utne, J. G., & Jaffe, R. (2004) · Anesthesiology · doi:10.1097/00000542-200402000-00017 · Cited by 30
Junttila, E., Koskenkari, J. K., Ohtonen, P. P., & Ala-Kokko, T. I. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer170 · Cited by 28
Cua, C. L., Thomas, K., Zurakowski, D., & Laussen, P. C. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000149591.67207.05 · Cited by 26
Wurzer, P., Branski, L. K., Jeschke, M. G., Ali, A., Kinsky, M. P., Bohanon, F. J., Hundeshagen, G., Norbury, W. B., Williams, F. N., Kamolz, L., et al. (2016) · Shock · doi:10.1097/shk.0000000000000627 · Cited by 25
Suehiro, K., Joosten, A., Alexander, B. S., & Cannesson, M. P. (2014) · Current anesthesiology reports · doi:10.1007/s40140-014-0074-5 · Cited by 25
Cardiac output monitoring devices: an analytic review
Porhomayon, J., El-Solh, A., Papadakos, P. J., & Nader, N. D. (2011) · Internal and Emergency Medicine · doi:10.1007/s11739-011-0738-9 · Cited by 22
Wasse, H. (2006) · Seminars in Dialysis · doi:10.1111/j.1525-139x.2006.00219.x · Cited by 22
Defining Goals of Resuscitation in the Critically Ill Patient
Joosten, A., Alexander, B. S., & Cannesson, M. P. (2014) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.006 · Cited by 21
Management of an Unusual Complication During Placement of a Pulmonary Artery Catheter
Bhatia, P., Saied, N. N., & Comunale, M. E. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000133244.59867.6f · Cited by 20
Narrative Review of Decision-Making Processes in Critical Care
Ruiz, A. A., Wyszyńska, P., & Laudański, K. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003683 · Cited by 18
Chen, G., Zuo, Y., Lei, Y., Elena, C., & Cannesson, M. P. (2014) · Journal of Biomedical Research · doi:10.7555/jbr.28.20130197 · Cited by 18
Highstead, R. G., Tipton, K. D., Creson, D. L., Wolfe, R. R., & Ferrando, A. A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01076.2004 · Cited by 20
Hemodynamic Monitoring in the Critically Ill: Spanning the Range of Kidney Function
Davison, D. L., Patel, K., & Chawla, L. S. (2012) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2011.12.016 · Cited by 15
The changes of pulmonary blood flow in non-ventilated lung during one lung ventilation
Gong, Q., Yang, Z., & Wei, W. (2010) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-010-9262-0 · Cited by 14
Magkoutas, K., Weisskopf, M., Falk, V., Emmert, M. Y., Meboldt, M., Cesarovic, N., & Daners, M. S. (2023) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2022.12.008 · Cited by 14
Togashi, K., Nandate, K., Hoaglan, C. D., Sherman, B., & Bowdle, A. T. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31828a6e53 · Cited by 14
[Pseudoaneurysm in the radial artery after catheterization].
Pérez, M. L., Jiménez, J. M. G., & Ruiz, A. J. (2006) · PubMed · Cited by 13
Silva, J. M., Menezes, P. F. L., Lobo, S. M., Carvalho, F. H. S., Oliveira, M. A. N., Filho, F. N. F. C., Fernando, B. N., Carmona, M. J. C., Teich, V., & Malbouisson, L. M. S. (2020) · BMC Anesthesiology · doi:10.1186/s12871-020-00987-y · Cited by 11
Occurrence and removal of a knotted pulmonary artery catheter: a case report.
Eshkevari, L., & Baker, B. M. (2007) · PubMed · Cited by 11
Wang, Z., Chen, G., Lu, K., Zhu, Y. S., & Chen, Y. (2019) · BMC Anesthesiology · doi:10.1186/s12871-019-0899-z · Cited by 14
Kumar, K., Nepomuceno, R. G., Chelvanathan, A., Golian, M., Bohonis, S., Cleverley, K., Ravandi, A., Mackenzie, S., & Jassal, D. S. (2012) · Echocardiography · doi:10.1111/echo.12049 · Cited by 10
Pulmonary Artery Catheter Monitoring
Vender, J. S. (1988) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(21)00243-1 · Cited by 10
Waldauf, P., Jiroutková, K., & Duška, F. (2019) · Critical Care Research and Practice · doi:10.1155/2019/5364503 · Cited by 9
Pulmonary artery rupture during Swan-Ganz catheterisation: A case report
Villaverde, R. V., Vanhaebost, J., Grabherr, S., & Palmière, C. (2013) · Legal Medicine · doi:10.1016/j.legalmed.2013.11.003 · Cited by 9
Vender, J. S. (1988) · Critical Care Clinics · doi:10.1016/s0749-0704(18)30476-7 · Cited by 9
Huang, H., Deng, M., Jin, H., Dirsch, O., & Dahmen, U. (2010) · Laboratory Animals · doi:10.1258/la.2009.009055 · Cited by 7
Advances in Critical Care for the Nephrologist
Davison, D. L., & Junker, C. D. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01440307 · Cited by 7
[Persistent left superior vena cava: infrequent localization of central venous catheter].
Carrillo-Esper, R., Contreras-Domínguez, V., Salmerón-Nájera, P., Carvajal-Ramos, R., Hernández-Aguilar, C., & Juárez-Uribe, A. (2003) · PubMed · Cited by 7
Jacquet‐Lagrèze, M., Bredèche, F., Louyot, C., Pozzi, M., Grinberg, D., Flagiello, M., Portran, P., Ruste, M., Schweizer, R., & Fellahi, J.-L. (2023) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2023.04.024 · Cited by 6
Blood Pressure Estimation Using Explainable Deep-Learning Models Based on Photoplethysmography
Perdereau, J., Chamoux, T., Gayat, É., Gall, A. L., Vallée, F., Cartailler, J., & Joachim, J. (2024) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000007295 · Cited by 6
Approach To Swan Ganz Thermodilution Catheter Complications: 6 Years Experience With 2310 Cases
(2008) · The Internet Journal of Thoracic and Cardiovascular Surgery · doi:10.5580/b73 · Cited by 6
Chaparro-Mendoza, K. (2012) · Colombian Journal of Anesthesiology · doi:10.1016/j.rcae.2012.05.007 · Cited by 6
Transient Pulmonary Artery Hypertension in Holstein Neonate Calves
Yasuoka, M. M., Monteiro, B. M., Neto, P. F., Paiano, R. B., Fantoni, D. T., Otsuki, D. A., & Birgel, E. H. (2020) · Animals · doi:10.3390/ani10122277 · Cited by 6
Less Invasive Cardiac Output Monitoring: Characteristics and Limitations
Hofer, C. K., & Zollinger, A. (2006) · Yearbook of intensive care and emergency medicine · doi:10.1007/3-540-33396-7_16 · Cited by 6
Meng, X., Zang, G., Fan, L., Zheng, L., DAI, J., WANG, X., Xia, W., Liu, J., & Zhang, C. (2013) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2013.1121 · Cited by 5
Owusu‐Bediako, K., Bekiroglu, I. H., Rice‐Weimer, J., Murillo-Deluquez, M., & Tobias, J. D. (2022) · Cardiology Research · doi:10.14740/cr1378 · Cited by 5
Gangrene of digits associated with radial artery cannulation
Wong, A. Y. C., & O’Regan, A. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03415_15.x · Cited by 5
de Oliveira, H. P., Pinto, R. A., Souto, E., & Giusti, R. (2024) · Applied Sciences · doi:10.3390/app14062470 · Cited by 5
Wireless Telemetry System for Implantable Sensors
Fricke, K. (2012) · Scholarship@Western (Western University) · Cited by 4
Anesthésie et réanimation en chirurgie cardiaque. Activité en 1982 des Centres français
Depoix, J., Desmonts, J.-M., & Tiret, L. (1984) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(84)80149-5 · Cited by 4
Chaparro-Mendoza, K. (2012) · Colombian Journal of Anesthesiology · doi:10.1016/j.rca.2012.05.014 · Cited by 4
Managing critically ill patients with a pulmonary artery catheter
Harvey, S. E., & Singer, M. (2006) · British Journal of Hospital Medicine · doi:10.12968/hmed.2006.67.8.21977 · Cited by 4
Bedside Clinician’s Guide to Pulmonary Artery Catheters
Fox, W. E., Marshall, M., Walters, S. M., Mangunta, V. R., Ragosta, M., Kleiman, A. M., & McNeil, J. S. (2023) · Critical Care Nurse · doi:10.4037/ccn2023133 · Cited by 3
Kim, J., Ivanović, S. R., Davison, D. L., Bheem, R., Wu, M., Sweeney, B., Shaykhinurov, E., & Yamane, D. P. (2024) · Journal of Intensive Care Medicine · doi:10.1177/08850666241265190 · Cited by 3
Diagnosis and Rescue of a Kinked Pulmonary Artery Catheter
Mouawad, N. J., Stein, E. J., Moran, K. R., Go, M. R., & Papadimos, T. J. (2015) · Case Reports in Anesthesiology · doi:10.1155/2015/567925 · Cited by 3
Peng, C. (2008) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 3
Leeuw, M. D., & Jacobs, W. (2008) · American Journal of Forensic Medicine & Pathology · doi:10.1097/paf.0b013e318183455a · Cited by 3
Less Invasive Cardiac Output Monitoring: Characteristics and Limitations
Hofer, C. K., & Zollinger, A. (2006) · Springer eBooks · doi:10.1007/0-387-35096-9_16 · Cited by 3
Sweeney, B., Kim, J., Adnani, A., Saleem, H., Akben, S., Teo, Y. R. A., Shaykhinurov, E., Wu, M., Bheem, R., Islam, S., et al. (2025) · Journal of Intensive Care Medicine · doi:10.1177/08850666251368867 · Cited by 2
Sack, S., Kahlert, P., Philipp, S., Kottenberg‐Assenmacher, E., Churzidse, S., Konorza, T. F. M., Peters, J., & Erbel, R. (2007) · Intensivmedizin und Notfallmedizin · doi:10.1007/s00390-007-0823-5 · Cited by 2
Emergency Department Management of Severe Sepsis
Frakes, M. A. (2007) · Advanced Emergency Nursing Journal · doi:10.1097/01.tme.0000286965.79040.f1 · Cited by 2
Arterial Access/Monitoring (Line Placement)
Nyberg, S. M., Bequillard, D. J., & Vasquez, D. G. (2016) · Springer eBooks · doi:10.1007/978-3-319-25286-5_11 · Cited by 2
Kim, D. H., Yoo, J. Y., Lee, S. Y., Kim, Y. J., Lee, S. R., & Park, S. Y. (2016) · Anesthesia and Pain Medicine · doi:10.17085/apm.2016.11.3.280 · Cited by 2
Telemetric Catheter-Based Pressure Sensor for Hemodynamic Monitoring: Experimental Experience
Mahnken, A. H., Urban, U., Fassbender, H., Schnakenberg, U., Schoth, F., & Schmitz‐Rode, T. (2009) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-009-9556-0 · Cited by 2
Establishing Vascular Access in the Trauma Patient
Joy, M. A., Marciniak, D. A., & Rubin, K. P. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511547447.007 · Cited by 1
Variant thoracic venous drainage and its hazards with catheter for haemodialysis
Balasubramanian, S., Nicholls, M., & Jones, C. H. (2013) · Clinical Kidney Journal · doi:10.1093/ckj/sft096 · Cited by 1
Chen, S., Lin, P., Zhen-shuang, D., Lan, F., Wu, S., Zhong, T., Liang, X., Liu, H., Zeng, C., & Zhang, C. (2014) · PubMed Central · Cited by 1
Correlation of Coronary Artery Disease with Risk Factors on Computed Tomography Angiography
Abidin, M. Z. U., Maryam, S., Khalil, H., Farooq, S. M. Y., Zakir, M., Jabeen, F. J., & Ijaz, F. (2021) · Pakistan Journal of Medical and Health Sciences · doi:10.53350/pjmhs211581795 · Cited by 1
Post-intensive care syndrome (PICS) – complications after ICU stay: selected issues
Wojnar-Gruszka, K., Wojtas, K., & Jędrocha, K. (2023) · Problemy Pielęgniarstwa · doi:10.5114/ppiel.2023.136172 · Cited by 1
[Complex regional pain syndrome type 2 after radial artery catheterization: a case report].
Valién, J. L., Tirado, J. A. S., Hernández, O. A., Blasco, P. C., Bellosta, A. P., & Lobera, J. C. (2006) · PubMed · Cited by 1
Paediatric intensive care training
Taylor, B., Donnison, P., & Marsh, M. J. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03415_2.x · Cited by 1
Kim, S. H., Kim, D., & Lee, J. S. (2005) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2005.49.5.684 · Cited by 1
Monitoring the Plastic Surgical Patient
Reines, H. D. (1985) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31711-9 · Cited by 1
Monitoring — Was ist wirklich wichtig?
Rex, S., & Bühre, W. (2005) · Springer eBooks · doi:10.1007/3-540-26858-8_13 · Cited by 1
Goal Directed Hemodynamic Optimization
Cannesson, M. P., & Pearse, R. M. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107257115.023
Monitoring of Cardiovascular and Respiratory Function
Barie, P. S., & Eachempati, S. R. (2008) · Springer eBooks · doi:10.1007/978-0-387-68113-9_22
Anaesthesia for Laparoscopic Urologic Surgery in Malignancies
Henny, C. P., & Hofland, J. (2005) · Springer eBooks · doi:10.1007/3-540-27606-8_26
Central venous catheter placement: An alternative of Certodyn ® (Universal Adapter)
Jain, M., Rastogi, B., Singh, V. P., & Gupta, K. (2011) · Anesthesia Essays and Researches · doi:10.4103/0259-1162.94798
Descending Necrotizing Mediastinitis: Unique Complication of Central Venous Catheterization
Caputo, F. J., Magnotti, L. J., Hauser, C. J., & Livingston, D. H. (2007) · Surgical Infections · doi:10.1089/sur.2006.071
Central venous oxygen saturation monitoring
Ladewig, E. L., & Lewis, P. (2009) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2009.4.2.39359
The Pulmonary Artery Catheter Sleeve – Protective or Infective?
Corcoran, T. B., Grape, S., Duff, O., Perry, P. L., & Murray, R. J. (2009) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0903700210
Sara García, T., C., J. A. N., Peña, E., & Bernal, A. (2010) · Revista Repertorio de Medicina y Cirugía · doi:10.31260/repertmedcir.v19.n1.2010.567
Asociación de catéter central como factor
Gallardo, L. C. H., Andrade, I. O., & Ortiz, S. G. (2008)
Endpoints of goal directed therapy in the OR and in the ICU
Waldron, N. H., Miller, T. E., & Gan, T. J. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107257115.025
Invasive Hemodynamic Monitoring
Newhouse, B. J., & Montecino, R. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-0973-5.10010-6
Reducing Errors in Cardiac Anesthesiology
Bowdle, A. T., Edwards, M., & Domino, K. B. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1617-7.00041-8
Vascular Access in the Intensive Care Unit
Gallagher, C., & Poovathor, S. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-3773-6.10044-8
Metadata
- Authors
- Bowdle, T. A.
- Venue
- Anesthesiology Clinics of North America
- Publisher
- Elsevier BV
- Published
- 2002-09
- Volume
- 20
- Issue
- 3
- Pages
- 571-588
- ISSN
- 0889-8537 (ISSN-L)
- OpenAlex
- W2119404588
- Cited by
- 112
- References
- 81
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 5 · 2022: 2 · 2021: 1 · 2020: 5 · 2019: 3 · 2018: 3 · 2017: 1 · 2016: 4 · 2015: 2 · 2014: 7 · 2013: 4 · 2012: 5
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesiology Clinics of North America (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Keywords
- invasive hemodynamic monitoring, arterial catheterization complications, central venous pressure catheter, pulmonary artery catheter, cardiac perforation, pulmonary artery perforation, hemoptysis, catheter positioning, chest radiography
- MeSH terms
- Catheterization, Catheterization, Central Venous, Catheterization, Swan-Ganz, Equipment Failure, Humans, Monitoring, Intraoperative
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review