Dihydrofluorescein diacetate is superior for detecting intracellular oxidants: comparison with 2′,7′-dichlorodihydrofluorescein diacetate, 5(and 6)-carboxy-2′,7′-dichlorodihydrofluorescein diacetate, and dihydrorhodamine 123
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
To detect intracellular oxidant formation during reoxygenation of anoxic endothelium, the oxidant-sensing fluorescent probes, 2',7'-dichlorodihydrofluorescein diacetate, dihydrorhodamine 123, or 5(and 6)-carboxy-2',7'-dichlorodihydrofluorescein diacetate were added to human umbilical vein endothelial cells during reoxygenation. None of these fluorescent probes were able to differentiate the controls from the reoxygenated cells in the confocal microscope. However, dihydrofluorescein diacetate demonstrated fluorescence of linear structures, consistent with mitochondria, in reoxygenated endothelium. This work tests the hypothesis that dihydrofluorescein diacetate is a better fluorescent probe for detecting intracellular oxidants because it is more reactive toward specific oxidizing species. To investigate this, dihydrofluorescein diacetate was exposed to various oxidizing species (hydrogen peroxide, superoxide [KO2], peroxynitrite, nitric oxide, horseradish peroxidase, ferric iron, xanthine oxidase, cytochrome c, and lipoxygenase) and compared with the three other popular probes. Though oxidized dihydrofluorescein has higher molar fluorescence, comparison of the reactions of dihydrofluorescein with these other three probes in a cell-free system indicates that dihydrofluorescein is sometimes less fluorescent than the other probes. In addition, we find that the reactivity of all of the probes is very complex. Based on the results reported here, it is no longer appropriate to think of these probes as detecting a specific oxidizing species in cells, such as H2O2, but rather as detectors of a broad range of oxidizing reactions that may be increased during intracellular oxidant stress. Cell-loading studies indicate that dihydrofluorescein achieves higher intracellular concentrations than the second brightest intracellular probe, 2',7'-dichlorodihydrofluorescein. This fact and its higher molar fluorescence may account for the superior brightness of dihydrofluorescein diacetate. Dihydrofluorescein diacetate may be a superior fluorescent probe for many cell-based studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“5-(and -6)-Carboxy-2′,7′-dihydrochlorofluorescein-diacetat (5/6-Carboxy-DCF) is a derivative of H2DCF-DA that contains two additional carboxyl groups that enhance its hydrophilicity and therefore strongly increase its retention in the cytosol. Therefore, in contrast to H2DCF-DA, which detects total cellular ROS levels, the green fluorescent 5/6-Carboxy-DCF can be used to specifically detect cytos”
From Functions of ROS in Macrophages and Antimicrobial Immunity (2021) · cites this paper as [359]
In the citing paper
“2′,7′-Dichlordihydrofluorescein-diacetat (H2DCF-DA) is a cell-permeable derivative of fluorescein and one of the most commonly used ROS probes. After its diffusion into the cytosol, the two acetate groups are cleaved by cellular esterases generating 2′,7′-dichlordihydrofluorescein (H2DCF). This molecule can now be oxidized by ROS to generate the highly green fluorescent 2′,7′-dichlorofluorescein (”
From Functions of ROS in Macrophages and Antimicrobial Immunity (2021) · cites this paper as [359]
Citations
Cites
Jaffe, E. A., Nachman, R. L., Becker, C. G., & Minick, C. R. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107470 · Cited by 6,856 · cited 3×
“Medium 199 (M199) contained 9.87 g/l medium 199 powder plus 2.2 g/l NaHCO3, 100,000 U/l penicillin G, 100 mg/l streptomycin, 300 mg/lL-glutamine, plus 10% FBS, pH 7.4.”
MethodInfluentialLeBel, C. P., Ischiropoulos, H., & Bondy, S. C. (1992) · Chemical Research in Toxicology · doi:10.1021/tx00026a012 · Cited by 2,689
Bass, D. A., Parce, J. W., Dechatelet, L. R., Szejda, P., Seeds, M. C., & Thomas, M. (1983) · The Journal of Immunology · doi:10.4049/jimmunol.130.4.1910 · Cited by 1,809 · cited 3×
“Although extracellular catalase has been shown to decrease intracellular fluorescence when extracellular H2O2 is added to cells [4,8], we tested if catalase itself may interact directly with these probes.”
BackgroundMethodLocalization of mitochondria in living cells with rhodamine 123.
Johnson, L. V., Walsh, M. L., & Chen, L. B. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.2.990 · Cited by 1,553 · cited 1×
“1B), is presumed to localize to mitochondria [10], whereas 5(and 6)-carboxy-29,79-dichlorodihydrofluorescein diacetate (5&6DH-DA), (Fig.”
BackgroundRoyall, J. A., & Ischiropoulos, H. (1993) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1993.1222 · Cited by 1,119
Rothe, G., & Valet, G. (1990) · Journal of Leukocyte Biology · doi:10.1002/jlb.47.5.440 · Cited by 868
Detection of picomole levels of hydroperoxides using a fluorescent dichlorofluorescein assay
Cathcart, R., Schwiers, E., & Ames, B. N. (1983) · Analytical Biochemistry · doi:10.1016/0003-2697(83)90270-1 · Cited by 852 · cited 14×
“After treatment with HRP, the fluorescence from cells treated with HFLUOR-DA is about three times higher than DCHF-DA–treated cells.”
ResultInfluentialPeroxynitrite-mediated oxidation of dihydrorhodamine 123
Kooy, N. W., Royall, J. A., Ischiropoulos, H., & Beckman, J. S. (1994) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)90138-4 · Cited by 719 · cited 1×
“Recent reports indicate that fluorescent probes may react with peroxynitrite (ONOO(2)) and NO [29,30].”
BackgroundIntracellular hydrogen peroxide and superoxide anion detection in endothelial cells
Carter, W. O., Naryanan, P. K., & Robinson, J. P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.2.253 · Cited by 635 · cited 7×
“Although extracellular catalase has been shown to decrease intracellular fluorescence when extracellular H2O2 is added to cells [4,8], we tested if catalase itself may interact directly with these probes.”
BackgroundMethodInfluentialCrow, J. P. (1997) · Nitric Oxide · doi:10.1006/niox.1996.0113 · Cited by 626 · cited 1×
“Recent reports indicate that fluorescent probes may react with peroxynitrite (ONOO(2)) and NO [29,30].”
BackgroundThe fluorometric analysis of ultramicro quantities of hydrogen peroxide
Keston, A. S., & Brandt, R. (1965) · Analytical Biochemistry · doi:10.1016/0003-2697(65)90034-5 · Cited by 597 · cited 5×
“Shortly after publication of Keston and Brandt’s papers [1,2], DCHF-DA was used as a detector of intracellular oxidants [3].”
BackgroundMethodResultInfluentialBuettner, G. R. (1988) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(88)90100-5 · Cited by 509 · cited 1×
“100 beads to decrease adventious iron [21].”
Self-citationVowells, S. J., Sekhsaria, S., Malech, H. L., Shalit, M., & Fleisher, T. A. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)00247-t · Cited by 425 · cited 2×
“sensing probes react only with H 2O2 [6,8,20], but rather act as detectors of a broad range of intracellular oxidiz-”
BackgroundHyslop, P. A., & Sklar, L. A. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90457-3 · Cited by 315
Qian, S. Y., & Buettner, G. R. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00002-7 · Cited by 262 · cited 1×
“However, Fe 21 in the presence of oxygen forms reactive oxidants [25].”
BackgroundSelf-citationOxidation pathways for the intracellular probe 2′,7′-dichlorofluorescin
Zhu, H., Bannenberg, G. L., Moldéus, P., & Shertzer, H. G. (1994) · Archives of Toxicology · doi:10.1007/s002040050118 · Cited by 260
Agonist-Induced Peroxynitrite Production from Endothelial Cells
Kooy, N. W., & Royall, J. A. (1994) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1994.1178 · Cited by 250 · cited 1×
“«302 5 1670 M cm [22].”
The role of the phagocyte in host-parasite interactions
Paul, B., & Sbarra, A. J. (1968) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(68)90116-5 · Cited by 200 · cited 3×
“Fluorescence was then detected in cell lysates [3].”
BackgroundMethodSynthesis of diacetyldichlorofluorescin: A stable reagent for fluorometric analysis
Brandt, R., & Keston, A. S. (1965) · Analytical Biochemistry · doi:10.1016/0003-2697(65)90035-7 · Cited by 176 · cited 2×
“1A), in a cell-free system [1,2] generated interest in the use of fluorescent probes to detect cell-derived oxidants.”
BackgroundMethodUeber eine neue Klasse von Farbstoffen
Baeyer, A. (1871) · Berichte der deutschen chemischen Gesellschaft · doi:10.1002/cber.18710040209 · Cited by 163
Zulueta, J. J., Yu, F. S., Hertig, I. A., Thannickal, V. J., & Hassoun, P. M. (1995) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb.12.1.7529030 · Cited by 151
Kalyanaraman, B., Janzen, E. G., & Mason, R. P. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)89222-5 · Cited by 118 · cited 1×
“This result indicates that catalase by itself may act as an intracellular factor able to oxidize these probes to fluorescence [26] and that catalase may act as a cofactor for the reaction with H 2O2, perhaps due to peroxidase activity [28].”
BackgroundSanders, S. P., Zweier, J. L., Kuppusamy, P., Harrison, S. J., Bassett, D. J., Gabrielson, E. W., & Sylvester, J. T. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116198 · Cited by 110 · cited 1×
“We speculated that the mitochondria would be a likely source of oxidants during reoxygenation [17] and attempted to use confocal microscopy with these fluorescent probes to detect mitochondriaderived species during reoxygenation.”
BackgroundReoxygenation of endothelial cells increases permeability by oxidant-dependent mechanisms.
Lum, H., Barr, D. A., Shaffer, J. R., Gordon, R. J., Ezrin, A. M., & Malik, A. B. (1992) · Circulation Research · doi:10.1161/01.res.70.5.991 · Cited by 106 · cited 1×
“Initially, three intracellular fluorescent probes (DCHF-DA, DHR123, and 5&6DH-DA) were used in our laboratory as a tool to detect intracellular oxidants formed during reoxygenation of anoxic endothelial cells [13–17].”
MethodFLUORESCEIN AND SOME OF ITS DERIVATIVES
Orndorff, W. R., & Hemmer, A. J. (1927) · Journal of the American Chemical Society · doi:10.1021/ja01404a016 · Cited by 70 · cited 2×
“These findings indicate that HFLUOR-DA, first described as fluorescein in 1871, may be a useful tool for other investigators studying intracellular oxidants [18,19].”
BackgroundLokesh, B. R., & Cunningham, M. L. (1986) · Toxicology Letters · doi:10.1016/0378-4274(86)90147-5 · Cited by 39 · cited 1×
“Although reaction with H2O2 generated by KO2 is a possibility [8,31], these probes react slowly with Fig.”
BackgroundOmar, H. Α., Figueroa, R., Omar, R., Tejani, N. A., & Wolin, M. S. (1992) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(11)91658-5 · Cited by 37
The Use of Fluorescent Probes to Assess Oxidative Processes in Isolated-Perfused Rat Heart Tissue
Kehrer, J. P., & Paraidathathu, T. (1992) · Free Radical Research Communications · doi:10.3109/10715769209049175 · Cited by 37 · cited 1×
“1B), is supposed to be retained in the cell better than DCHF, thereby yielding more fluorescence [11,12].”
BackgroundReduced prostacyclin formation after reoxygenation of anoxic endothelium
Hempel, S. L., Haycraft, D. L., Hoak, J. C., & Spector, A. A. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.259.5.c738 · Cited by 35 · cited 5×
“Medium 199 (M199) contained 9.87 g/l medium 199 powder plus 2.2 g/l NaHCO3, 100,000 U/l penicillin G, 100 mg/l streptomycin, 300 mg/lL-glutamine, plus 10% FBS, pH 7.4.”
BackgroundMethodInfluentialSelf-citationMorita, I., Smith, W. L., DeWitt, D. L., & Schindler, M. (1995) · Biochemistry · doi:10.1021/bi00021a034 · Cited by 26 · cited 1×
“1B), is supposed to be retained in the cell better than DCHF, thereby yielding more fluorescence [11,12].”
BackgroundEffect of glutathione on endothelial prostacyclin synthesis after anoxia
Hempel, S. L., Wessels, D. A., & Spector, A. A. (1993) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1993.264.6.c1448 · Cited by 7 · cited 2×
“Previous studies have shown that this technique yields cultures of high purity with minimal variability in cell number or total protein from well to well [16,24].”
BackgroundMethodSelf-citation
Cited by
Halliwell, B., & Whiteman, M. (2004) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0705776 · Cited by 2,238
“Hempel et al. (1999) have stated that dihydrofluorescein diacetate has certain advantages over DCFDA in some cellular systems, but again it detects a range of RS. 2-[6- 40hydroxy]phenoxy-3H-xanthen-3-on-9-yl]benzoic acid (HPF) and 2-[6-(40amino)phenoxy-3H-xanthen-3-on-9-yl]benzoic acid (APF)…”
BackgroundFluorescence probes used for detection of reactive oxygen species
Gomes, A., Fernandes, E., & Lima, J. L. F. C. (2005) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2005.10.003 · Cited by 1,844
“APF and HPF were classified by Setsukinai et al. [100] as appropriate probes for detecting highly reactive ROS and RNS, meaning, HO!, ONOO and HOCl.”
BackgroundInfluentialChemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Measuring reactive oxygen and nitrogen species with fluorescent probes: challenges and limitations
Kalyanaraman, B., Darley-Usmar, V., Davies, K. J. A., Dennery, P. A., Forman, H. J., Grisham, M. B., Mann, G. E., Moore, K., Roberts, L. J., & Ischiropoulos, H. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2011.09.030 · Cited by 1,774
Setsukinai, K.-I., Urano, Y., Kakinuma, K., Majima, H. J., & Nagano, T. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m209264200 · Cited by 1,301
Metadata
- Authors
- Hempel, S. L., Buettner, G. R., O’Malley, Y. Q., Wessels, D. A., & Flaherty, D. M.
- Affiliations
- University of Iowa (US)
- Corresponding author
- Hempel, Stephen L
- ORCID
- Buettner, Garry R
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 1999-07
- Volume
- 27
- Issue
- 1-2
- Pages
- 146-159
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W2047758994
- Cited by
- 740
- References
- 31
- Citations by year
- 2026: 9 · 2025: 17 · 2024: 17 · 2023: 13 · 2022: 27 · 2021: 24 · 2020: 33 · 2019: 26 · 2018: 22 · 2017: 31 · 2016: 29 · 2015: 42 · 2014: 43 · 2013: 34 · 2012: 36
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Free Radical Biology and Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Cancer Institute (CA66081, P01CA066081)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Redox biology and oxidative stress
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Health Sciences › Medicine › Biochemistry (medical) › Antioxidant Activity and Oxidative Stress
- Keywords
- dihydrorhodamine 123, fluorescent probes, oxidative stress, reoxygenation, endothelial cells, mitochondria, hydrogen peroxide, superoxide, peroxynitrite, nitric oxide, cell loading
- MeSH terms
- Arachidonate 5-Lipoxygenase, Catalase, Cells, Cultured, Cytochrome c Group, Endothelium, Vascular, Ferric Compounds, Ferrous Compounds, Fluoresceins, Fluorescent Dyes, Glutathione Peroxidase, Horseradish Peroxidase, Humans, Hydrogen Peroxide, Intracellular Fluid, Rhodamines, Xanthine Oxidase, Molecular Structure, Oxidants, Microscopy, Confocal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.