CoChat

Ambulatory pulse pressure aspredictor of outcome in older patients with systolic hypertension

Open access
Staessen, J · 2002 · American Journal of Hypertension
Cited by 103

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We enrolled 808 older patients with isolated systolic hypertension (160 to 219/71 <95 mm Hg) to investigate whether ambulatory measurement of pulse pressure and mean pressure can refine risk stratification. The patients (> or =60 years) were randomized to nitrendipine (10 to 40 mg/day) with the possible addition of enalapril (5 to 20 mg/day) or hydrochlorothiazide (12.5 to 25 mg/day) or to matching placebos. At baseline, pulse pressure and mean pressure were determined from six conventional blood pressure (BP) readings and from 24-h ambulatory recordings. With adjustment for significant covariables, we computed mutually adjusted relative hazard rates associated with 10 mm Hg increases in pulse pressure or mean pressure. In the placebo group, the 24-h and nighttime pulse pressures consistently predicted total and cardiovascular mortality, all cardiovascular events, stroke, and cardiac events. Daytime pulse pressure predicted cardiovascular mortality, all cardiovascular end points, and stroke. The hazard rates for 10 mm Hg increases in pulse pressure ranged from 1.25 to 1.68. Conventionally measured pulse pressure predicted only cardiovascular mortality with a hazard rate of 1.35. In the active treatment group compared with the placebo patients, the relation between outcome and ambulatory pulse pressure was attenuated to a nonsignificant level. Mean pressure determined from ambulatory or conventional BP measurements was not associated with poorer prognosis. In conclusion, in older patients with isolated systolic hypertension higher pulse pressure estimated by 24-h ambulatory monitoring was a better predictor of adverse outcomes than conventional pulse pressure, whereas conventional and ambulatory mean pressures were not correlated with a worse outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(02)02987-4

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 103

Metadata

Authors
Staessen, J.
Venue
American Journal of Hypertension
Published
2002-10
Volume
15
Issue
10
Pages
835-843
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2151890472
Cited by
103
References
4
FWCI
6.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory pulse pressure aspredictor of outcome in older patients with systolic hypertension. https://app.cochat.ai/papers/10.1016/s0895-7061(02)02987-4
The paper
Staessen, J. (2002). Ambulatory pulse pressure aspredictor of outcome in older patients with systolic hypertension. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(02)02987-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.