Cited by 160Electrodeposition and Electroless CoatingsConducting polymers and applicationsDielectric materials and actuators

Fuzzy gold electrodes for lowering impedance and improving adhesion with electrodeposited conducting polymer films

Cui, Xinyan, Martin, David C.·2003·Sensors and Actuators A: Physical

Integrity signals

Registry

Crossref · 10.1016/s0924-4247(02)00427-2

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Electrical contacts for neuroscience applications have been engineered to increase effective surface area to reduce electrical impedance and increase charge injection capacity by roughening the surface through electroplating or nano-patterning.

    “Electrical contacts for neuroscience applications have since been engineered to increase the effective surface area to reduce the electrical impedance (and increase the charge injection capacity) by roughening the surface through electroplating (Cui and Martin 2003) or nano-patterning (Schlie-Wolter etal. 2013).”

    From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Cui and Martin 2003

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Cui, X., & Martin, D. C.
Affiliations
University of Michigan (US)
Corresponding author
Martin, David C.
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
2003-02
Volume
103
Issue
3
Pages
384-394
ISSN
0924-4247 (ISSN-L)
OpenAlex
W1990505926
Cited by
160
References
30
Citations by year
2026: 1 · 2025: 3 · 2024: 7 · 2023: 5 · 2022: 5 · 2021: 9 · 2020: 11 · 2019: 12 · 2018: 10 · 2017: 13 · 2016: 9 · 2015: 12 · 2014: 10 · 2013: 6 · 2012: 5
FWCI
4.68
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators A Physical (publishedVersion)
Funders
  • National Science Foundation
  • University of Florida
  • National Institutes of Health
  • National Institute on Deafness and Other Communication Disorders
  • National Center for Research Resources
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrodeposition and Electroless Coatings
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Dielectric materials and actuators
Keywords
gold plating, electrodeposited gold, conducting polymer films, polymer film adhesion, impedance, surface roughness, surface area, electropolymerization, current density

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review