CoChat

Morphological characterization of microspheres, films and implants prepared from poly(lactide-co-glycolide) and ABA triblock copolymers: is the erosion controlled by degradation, swelling or diffusion?

Witt, C · 2001 · European Journal of Pharmaceutics and Biopharmaceutics

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Erosion of biodegradable parenteral delivery systems (PDS) based on ABA copolymers consisting of poly(L-lactide-co-glycolide) (PLGA) A-blocks attached to polyethylene oxide (PEO) B-blocks, or PLGA is important for the release of macromolecular drugs. The degradation behavior of four types of PDS, namely extruded rods, tablets, films and microspheres, was studied with respect to molecular weight, mass, polymer composition and shape and microstructure of the PDS. For each device the onset time of bulk erosion (t(on)) and the apparent rate of mass loss (k(app)) were calculated. In the case of PLGA, the t(on) was 16.2 days for microspheres, 19.2 days for films and 30.1 days for cylindrical implants and tablets. The k(app) was 0.04 days(-1) for microspheres, 0.09 days(-1) for films, 0.11 days(-1) for implants and 0.10 days(-1) for tablets. The degradation rates were in the same range irrespective of the geometry and the micrographs of eroding PDS demonstrated pore formation; therefore, a complex pore diffusion mechanism seems to control the erosion of PLGA devices. In contrast, PDS based on ABA copolymers showed swelling, followed by a parallel process of molecular weight degradation and polymer erosion, independent of the geometry. The contact angles of ABA films increased either with decreasing PEO content or with increasing chain length of the PEO B-blocks. In summary, the insertion of a hydrophilic B-block leads to an erosion controlled by degradation of ABA copolymers, wherea…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0939-6411(01)00130-8

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Cited by

See all 77

Metadata

Authors
Witt, C.
Affiliations
Philipps University of Marburg (DE)
Corresponding author
Witt, C
Venue
European Journal of Pharmaceutics and Biopharmaceutics
Publisher
Elsevier BV
Published
2001-05
Volume
51
Issue
3
Pages
171-181
ISSN
0939-6411 (ISSN-L)
OpenAlex
W2000124984
Cited by
77
References
28
Citations by year
2026: 3 · 2024: 5 · 2023: 1 · 2022: 2 · 2021: 1 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 3 · 2015: 7 · 2014: 4 · 2013: 3 · 2012: 3
FWCI
3.19
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • European Journal of Pharmaceutics and Biopharmaceutics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
Keywords
poly(lactic-co-glycolic acid), ABA triblock copolymers, poly(ethylene oxide), bulk erosion, drug release, intraparticle diffusion, polymer swelling, molecular weight degradation, microspheres, cinema, implants, contact angle
MeSH terms
Biodegradation, Environmental, Diffusion, Microscopy, Electron, Scanning, Microspheres, Motion Pictures, Polyglactin 910, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphological characterization of microspheres, films and implants prepared from poly(lactide-co-glycolide) and ABA triblock copolymers: is the erosion controlled by degradation, swelling or diffusion? https://app.cochat.ai/papers/10.1016/s0939-6411(01)00130-8
The paper
Witt, C. (2001). Morphological characterization of microspheres, films and implants prepared from poly(lactide-co-glycolide) and ABA triblock copolymers: is the erosion controlled by degradation, swelling or diffusion? European Journal of Pharmaceutics and Biopharmaceutics. https://doi.org/10.1016/s0939-6411(01)00130-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.