The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Biological effects of off-pump vs. on-pump coronary artery surgery: focus on inflammation, hemostasis and oxidative stress
Open accessAbstract
Cardiopulmonary bypass (CPB) has been recognized as a cause of complex systemic inflammatory response, which significantly contributes to several adverse postoperative complications. In the last few years, off-pump coronary artery bypass grafting has gained widespread diffusion as an alternative technique to conventional on-pump coronary artery bypass grafting. Surgeons supporting off-pump surgery state that the avoidance of the CPB and myocardial ischemia-reperfusion significantly reduces the postoperative systemic inflammatory response and other biological derangements and, possibly, may improve the clinical outcomes. We review, here, the available evidence concerning possible differences between off-pump and on-pump procedures in terms of inflammation, hemostasis and oxidative stress. Consistent differences in the involvement of these systems are observed, but they are limited to the final steps of the surgical procedures and the early hours after. These findings suggest that the global surgical trauma may be as important, or even more, as the CPB in terms of systemic inflammatory and coagulation-fibrinolytic pathway activation. Further studies are needed in order to confirm this hypothesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Nonrandomized studies have shown a marked difference in complement activation (C3a, C5a) between on-pump and off-pump CPB patients [7].”
From Oral neutrophils are an independent marker of the systemic inflammatory response after cardiac bypass (2014) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endothelial dysfunction in cardiovascular diseases: the role of oxidant stress
Cai, H., & Harrison, D. G. (2000) · Circulation Research · doi:10.1161/01.res.87.10.840 · Cited by 3,839
Van Snick, J. (1990) · Annual Review of Immunology · doi:10.1146/annurev.iy.08.040190.001345 · Cited by 1,890
Hypercholesterolemia increases endothelial superoxide anion production.
Ohara, Y., Peterson, T. E., & Harrison, D. G. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116491 · Cited by 1,765
Complement and the damaging effects of cardiopulmonary bypass
Kirklin, J. K., Westaby, S., Blackstone, E. H., Kirklin, J. W., Chenoweth, D. E., & Pacifico, A. D. (1983) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)39061-0 · Cited by 1,322
Chenoweth, D. E., Cooper, S. W., Hugli, T. E., Stewart, R. W., Blackstone, E. H., & Kirklin, J. W. (1981) · New England Journal of Medicine · doi:10.1056/nejm198102263040901 · Cited by 1,146
Angelini, G. D., Taylor, F. C., Reeves, B. C., & Ascione, R. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08216-8 · Cited by 561
Early Outcome After Off-Pump Versus On-Pump Coronary Bypass Surgery
van Dijk, D., Nierich, A. P., Jansen, E. W. L., Nathoe, H. M., Suyker, W. J. L., Diephuis, J. C., van Boven, W. J., Borst, C., Buskens, E., Grobbee, D. E., et al. (2001) · Circulation · doi:10.1161/hc4001.097036 · Cited by 508
Inflammatory response after coronary revascularization with or without cardiopulmonary bypass
Ascione, R., Lloyd, C. T., Underwood, M. J., Lotto, A. A., Pitsis, A. A., & Angelini, G. D. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01152-8 · Cited by 494
Endothelial cell binding of NAP-1/IL-8: role in neutrophil emigration
Rot, A. (1992) · Immunology Today · doi:10.1016/0167-5699(92)90039-a · Cited by 468
Off-pump coronary artery bypass grafting decreases risk-adjusted mortality and morbidity
Cleveland, J. C., Shroyer, A. L., Chen, A. Y., Peterson, E. D., & Grover, F. L. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)03006-5 · Cited by 452
Research works printed but not linked: 3
- Parolari A, Alamanni F, Cannata A, Naliato M, Bonati L, Rubini P, Veglia F, Tremoli E, Biglioli P. OPCAB vs. CABG: meta-analysis of currently available randomized trials. Ann Thorac Surg, in press
- Reents W, Babin-Ebell J, Misoph MR, Schwarzkopf A, Elert O. Influence of different autotransfusion devices on the quality of the salvaged blood. Ann Thorac Surg 1999;68:58-62.
- Tabuchi N, Sunamori M. Remaining procoagulant property of wound blood washed by a cell-saver device (letter). Ann Thorac Surg 2001; 71:1749.
Cited by
Sorted by citations
Raedschelders, K., Ansley, D. M., & Chen, D. D. Y. (2011) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2011.11.004 · Cited by 393
Afilalo, J., Rasti, M., Ohayon, S. M., Shimony, A., & Eisenberg, M. J. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr307 · Cited by 185
Chemokines Are Associated With Delirium After Cardiac Surgery
Rudolph, J. L., Ramlawi, B., Kuchel, G. A., McElhaney, J. E., Xie, D., Sellke, F. W., Khabbaz, K. R., Levkoff, S. E., & Marcantonio, E. R. (2008) · The Journals of Gerontology Series A · doi:10.1093/gerona/63.2.184 · Cited by 184
Anastasiadis, K., Antonitsis, P., Haidich, A., Argiriadou, H., Deliopoulos, A., & Papakonstantinou, C. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.01.020 · Cited by 136
Narrative review of the systemic inflammatory reaction to cardiac surgery and cardiopulmonary bypass
Squiccimarro, E., Stasi, A., Lorusso, R., & Paparella, D. (2022) · Artificial Organs · doi:10.1111/aor.14171 · Cited by 126
Metadata
- Authors
- Biglioli, P.
- Affiliations
- University of Milan (IT)
- Corresponding author
- Biglioli, P
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-08
- Volume
- 24
- Issue
- 2
- Pages
- 260-269
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2098507195
- Cited by
- 209
- References
- 66
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 9 · 2023: 6 · 2022: 4 · 2021: 5 · 2020: 7 · 2019: 7 · 2018: 2 · 2017: 7 · 2016: 11 · 2015: 7 · 2014: 11 · 2013: 5 · 2012: 13
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Journal of Cardio-Thoracic Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Cardiac and Coronary Surgery Techniques
- Health Sciences › Medicine › Hematology › Blood transfusion and management
- Health Sciences › Medicine › Surgery › Transplantation: Methods and Outcomes
- Keywords
- off-pump coronary artery bypass, on-pump coronary artery bypass grafting, cardiopulmonary bypass, systemic inflammatory response, hemostasis, oxidative stress, myocardial ischemia-reperfusion injury, postoperative complications, surgical trauma
- MeSH terms
- C-Reactive Protein, Cardiopulmonary Bypass, Complement Activation, Coronary Disease, Fibrinolysis, Heart-Assist Devices, Hemostasis, Humans, Inflammation, Interleukins, Leukocytes, Pancreatic Elastase, Platelet Aggregation, Time Factors, Tumor Necrosis Factor-alpha, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review