Ion-ion proton transfer reactions of bio-ions involving noncovalent interactions: Holomyoglobin
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Multiply protonated horse skeletal muscle holomyoglobin and apomyoglobin have been subjected to ion-ion proton transfer reactions with anions derived from perfluoro-1,3-dimethylcyclohexane in a quadrupole ion trap operated with helium as a bath gas at 1 mtorr. Neither the apomyoglobin nor holomyoglobin ions show any sign of fragmentation associated with charge state reduction to the 1 + charge state. This is particularly noteworthy for the holomyoglobin ions, which retain the noncovalently bound heme group. For example, no sign of heme loss is associated with charge state reduction from the 9 + charge state of holomyoglobin to the 1 + charge state despite the eight consecutive highly exothermic proton transfer reactions required to bring about this charge change. This result is consistent with calculations that show the combination of long ion lifetime and the high ion-helium collision rate relative to the ion-ion collision rate makes fragmentation unlikely for high mass ions in the ion trap environment even for noncovalently bound complexes of moderate binding strength. The ion-ion proton transfer rates for holo- and apomyoglobin ions of the same charge state also were observed to be indistinguishable, which supports the expectation that ion-ion proton transfer rates are insensitive to ion structure and are determined primarily by the attractive Coulomb field.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a multiply charged cation is let to react with a singly charged anion (typically originated from a perfluorinated molecule) to generate a cation with reduced charge state and a neutral molecule (that produces no signal during m/z analysis)”
From Proton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms (2019) · cites this paper as [31]
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
Katta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475
Correction of13C Mass Isotopomer Distributions for Natural Stable Isotope Abundance
Fernandez, C. A., Rosiers, C. D., Previs, S. F., David, F., & Brunengraber, H. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199603)31:3<255::aid-jms290>3.0.co;2-3 · Cited by 397
Nordhoff, E., Ingendoh, A., Cramer, R., Overberg, A., Stahl, B., Karas, M., Hillenkamp, F., Crain, P. F., & Chait, B. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290061212 · Cited by 297
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Research works printed but not linked: 3
- Smith R. D., 1992, Mass Spectrom. Rev., 11, 434
- Herron, W. J.; Goeringer, D. E.; McLuckey, S. A. Proceedings of the 42nd ASMS Conference on Mass Spectrometry and Allied Topics; May 29–June 3, 1994; 213.
- Stephenson, J. L., Jr.; McLuckey, S. A. Int. J. Mass Spectrom. Ion Processes in press.
Cited by
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Zubarev, R. A., Haselmann, K. F., Budnik, B., Kjeldsen, F., & Jensen, F. (2002) · European Journal of Mass Spectrometry · doi:10.1255/ejms.517 · Cited by 248
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.0.co;2-j · Cited by 233
Self-citationAnion dependence in the partitioning between proton and electron transfer in ion/ion reactions
Coon, J. J., Syka, J. E. P., Schwartz, J. C., Shabanowitz, J., & Hunt, D. F. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.05.005 · Cited by 185
McAlister, G. C., Phanstiel, D., Good, D. M., Berggren, W. T., & Coon, J. J. (2007) · Analytical Chemistry · doi:10.1021/ac070020k · Cited by 173
Controlling Charge States of Large Ions
Scalf, M., Westphall, M. S., Krause, J., Kaufman, S. L., & Smith, L. M. (1999) · Science · doi:10.1126/science.283.5399.194 · Cited by 168
Quadrupole ion trap mass spectrometry: a view at the turn of the century
March, R. E. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00345-6 · Cited by 157
Stephenson, J. L., & McLuckey, S. A. (1998) · Analytical Chemistry · doi:10.1021/ac9802832 · Cited by 141
Self-citationProton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms
Huguet, R., Mullen, C., Srzentić, K., Greer, J. B., Fellers, R. T., Zabrouskov, V., Syka, J. E. P., Kelleher, N. L., & Fornelli, L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03925 · Cited by 94
McLuckey, S. A., Stephenson, J. L., & Asano, K. G. (1998) · Analytical Chemistry · doi:10.1021/ac9710137 · Cited by 88
Self-citationFolding of Protein Ions in the Gas Phase after Cation-to-Anion Proton-Transfer Reactions
Laszlo, K. J., Munger, E. B., & Bush, M. F. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b04282 · Cited by 86
Chemical Mass Shifts in Ion Trap Mass Spectrometry: Experiments and Simulations
Wells, J. M., Plaß, W. R., Patterson, G. E., Ouyang, Z., Badman, E. R., & Cooks, R. G. (1999) · Analytical Chemistry · doi:10.1021/ac9902289 · Cited by 75
Competing fragmentation processes in tandem mass spectra of heparin-like glycosaminoglycans
Naggar, E. F., Costello, C. E., & Zaia, J. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.06.019 · Cited by 71
Laszlo, K. J., & Bush, M. F. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1245-4 · Cited by 61
Wells, J. M., Chrisman, P. A., & McLuckey, S. A. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00364-6 · Cited by 56
Self-citationIon/ion chemistry as a top-down approach for protein analysis
Stephenson, J. L., McLuckey, S. A., Reid, G. E., Wells, J. M., & Bundy, J. L. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00285-9 · Cited by 56
Self-citationStephenson, J. L., & McLuckey, S. A. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00025-7 · Cited by 55
Self-citationGoeringer, D. E., & McLuckey, S. A. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14043-5 · Cited by 54
Self-citationThe influence of electrostatic interactions on the detection of heme-globin complexes in ESI-MS
Schmidt, A., & Karas, M. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00294-x · Cited by 49
Frey, B. L., Lin, Y., Westphall, M. S., & Smith, L. M. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.07.019 · Cited by 45
Ugrin, S. A., English, A. M., Syka, J. E. P., Bai, D. L., Anderson, L. C., Shabanowitz, J., & Hunt, D. F. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02290-8 · Cited by 44
Ion/ion chemistry of high‐mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.3.co;2-a · Cited by 41
Self-citationExposing the molecular heterogeneity of glycosylated biotherapeutics
Schachner, L., Mullen, C., Phung, W., Hinkle, J., Beardsley, M. I., Bentley, T., Day, P., Tsai, C., Sukumaran, S., Baginski, T., et al. (2023) · doi:10.21203/rs.3.rs-2928767/v1 · Cited by 37
Exposing the molecular heterogeneity of glycosylated biotherapeutics
Schachner, L. F., Mullen, C., Phung, W., Hinkle, J. D., Beardsley, M. I., Bentley, T., Day, P., Tsai, C., Sukumaran, S., Baginski, T., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47693-8 · Cited by 36
Exposing the molecular heterogeneity of glycosylated biotherapeutics
Schachner, L. F., Mullen, C., Phung, W., Hinkle, J. D., Beardsley, M. I., Bentley, T., Day, P., Tsai, C., Sukumaran, S., Baginski, T., et al. (2023) · doi:10.1101/2023.05.10.540271 · Cited by 36
Effects of ion/ion proton transfer reactions on conformation of gas-phase cytochrome c ions
Zhao, Q., Schieffer, G. M., Soyk, M. W., Anderson, T. J., Houk, R. S., & Badman, E. R. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.03.032 · Cited by 35
Loss of charged versus neutral heme from gaseous holomyoglobin ions
Chrisman, P. A., Newton, K. A., Reid, G. E., Wells, J. M., & McLuckey, S. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.512 · Cited by 34
Self-citationLaszlo, K. J., Buckner, J. H., Munger, E. B., & Bush, M. F. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1620-4 · Cited by 33
Ray, S. S., Singh, S. K., & Balaram, P. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00206-9 · Cited by 33
Hao, C., & March, R. E. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00465-1 · Cited by 33
Positive Ion Transmission Mode Ion/Ion Reactions in a Hybrid Linear Ion Trap
Wu, J., Hager, J. W., Xia, Y., Londry, F. A., & McLuckey, S. A. (2004) · Analytical Chemistry · doi:10.1021/ac049359m · Cited by 30
Self-citationFrey, B. L., Krusemark, C. J., Ledvina, A. R., Coon, J. J., Belshaw, P. J., & Smith, L. M. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.07.029 · Cited by 25
Reactions of poly(ethylene glycol) cations with iodide and perfluorocarbon anions
Stephenson, J. L., & McLuckey, S. A. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00066-x · Cited by 25
Self-citationTargeted ion parking for the quantitation of biotherapeutic proteins: Concepts and preliminary data
Campbell, J. L., & Blanc, J. C. Y. L. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.08.015 · Cited by 22
Novel quadrupole ion trap methods for characterizing the chemistry of gaseous macro-ions
McLuckey, S. A., Wells, J. M., Stephenson, J. L., & Goeringer, D. E. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00306-7 · Cited by 19
Self-citationHydrogen/deuterium exchange of myoglobin ions in a linear quadrupole ion trap
Mao, D., Ding, C., & Douglas, D. J. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.810 · Cited by 18
Effects of charge on protein ion structure: Lessons from cation‐to‐anion, proton‐transfer reactions
Gozzo, T. A., & Bush, M. F. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21847 · Cited by 16
GPU Assisted Simulation Study of Ion–Ion Reactions within Quadrupole Ion Traps
Guo, D., He, M., Wang, Y. Z., Xiong, X., Fang, X., & Xu, W. L. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1098-x · Cited by 15
Proton hydrates as soft ion/ion proton transfer reagents for multiply deprotonated biomolecules
Bowers, J. J., Hodges, B. D. M., Saad, O. M., Leary, J. A., & McLuckey, S. A. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.05.038 · Cited by 14
Self-citationYue, L., Guo, C., Chai, Y., Yin, X., & Pan, Y. (2014) · Tetrahedron · doi:10.1016/j.tet.2014.10.067 · Cited by 13
Kit, M. C. S., Shepherd, S. O., Prell, J. S., & Webb, I. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00025 · Cited by 12
Lu, M., Yang, Y., & Chu, T. (2017) · Theoretical Chemistry Accounts · doi:10.1007/s00214-017-2088-9 · Cited by 12
Ion-ion proton transfer reactions of multiply-charged oligonucleotide cations
Stephenson, J. L., & McLuckey, S. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00176-6 · Cited by 11
Self-citationPitteri, S. J., Chrisman, P. A., Badman, E. R., & McLuckey, S. A. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.11.028 · Cited by 8
Self-citationIon parking in native mass spectrometry
Pizzala, N. J., Bhanot, J. S., Carrick, I. J., Dziekonski, E. T., & McLuckey, S. A. (2024) · The Analyst · doi:10.1039/d4an00242c · Cited by 7
Self-citationExploring the Gas‐Phase Formation and Chemical Reactivity of Highly Reduced M8L6 Coordination Cages
Pfrunder, M. C., Marshall, D. L., Poad, B. L. J., Stovell, E. G., Loomans, B. I., Blinco, J. P., Blanksby, S. J., McMurtrie, J. C., & Mullen, K. M. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202212710 · Cited by 7
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:1<83::aid-mas4>3.0.co;2-n · Cited by 5
Self-citationIn vacuo formation of peptide–metal coordination complexes
McAlister, G. C., Kiessel, S. E. B., & Coon, J. J. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.05.001 · Cited by 4
Schmidt, A. (2000) · Publication Server of Goethe University Frankfurt am Main (Goethe University Frankfurt) · Cited by 2
Exploring the Gas‐Phase Formation and Chemical Reactivity of Highly Reduced M8L6 Coordination Cages
Pfrunder, M. C., Marshall, D. L., Poad, B. L. J., Stovell, E. G., Loomans, B. I., Blinco, J. P., Blanksby, S. J., McMurtrie, J. C., & Mullen, K. M. (2022) · Angewandte Chemie · doi:10.1002/ange.202212710 · Cited by 1
Horn, S. A., Pizzala, N. J., & McLuckey, S. A. (2026) · Canadian Journal of Chemistry · doi:10.1139/cjc-2025-0266 · Cited by 1
Self-citationMethods for Multi-Stage Ion Processing Involving Ion/Ion Chemistry in a Quadrupole Linear Ion Trap
McAlister, G. C., & Coon, J. J. (2009) · CRC Press eBooks · doi:10.1201/9781420083743-c3 · Cited by 1
Soyk, M. W. (2008) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-1176 · Cited by 1
Extending the frontiers of mass spectrometric instrumentation and methods
Schieffer, G. M., & USDOE Office of Science (SC) (2010) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1037883 · Cited by 1
Electrospray/Ion Trap Mass Spectrometry for the Detection and Identification of Organisms
McLuckey, S. A., & Stephenson, J. L. (1997) · University of North Texas Digital Library (University of North Texas)
Self-citationBornschein, R. E. (2015) · Deep Blue (University of Michigan)
Laszlo, K. J. (2017) · ResearchWorks at the University of Washington (University of Washington)
Metadata
- Authors
- Stephenson, J. L., Van Berkel, G. J., & McLuckey, S. A.
- Affiliations
- Oak Ridge National Laboratory (US)
- Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
- ORCID
- McLuckey, Scott A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-06-01
- Volume
- 8
- Issue
- 6
- Pages
- 637-644
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2071498033
- Semantic Scholar
- 4a21e6ab14dfdcd015706ec440fbdc6068486d10
- Cited by
- 51
- References
- 42
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2019: 2 · 2017: 2 · 2016: 1 · 2015: 2 · 2014: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- apomyoglobin, heme, ion fragmentation, ion lifetime, electrostatic attraction, proton transfer rate, Paul trap
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.