Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Previously, the highest molecular weight for a sample yielding a unit resolution mass spectrum was 67 kDa (marginal at 86 kDa), obtained with a 6. 2 T Fourier-transform mass spectrometer with electrospray ionization. Now with a 9. 4 T instrument, resolving power of 170,000 has been achieved for chondroitinase I (997 amino acids) and II (990 amino acids), making possible molecular weight assignments of 112,509 and 111,714, respectively, versus 112,508 and 111,713 calculated. Assisting these assignments was the noise reduction in the resolved isotopic peaks achieved by the time domain data sampling technique introduced by Senko, Marshall, and co-workers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Self-citation
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Self-citationSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationProteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Metadata
- Authors
- Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-04-01
- Volume
- 8
- Issue
- 4
- Pages
- 380-383
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2079174216
- Cited by
- 122
- References
- 1
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy. https://app.cochat.ai/papers/10.1016/s1044-0305(97)00060-3
- The paper
- Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W. (1997). Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(97)00060-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.