Evolution in impedance at the electrode‐skin interface of two types of surface EMG electrodes during long‐term recordings
The DOI matches its Crossref record; 19 of the 22 references it cites were found in a registry or an index.
Abstract
The evolution in impedance at the electrode-skin interface of Beckman and Red Dot electrodes was assessed during long-term recordings. Impedance was measured between each pair of electrodes, arranged in a bipolar configuration on tibialis anterior (n=13). A waveform constructed of sinusoids of known frequencies, evenly distributed on a log scale from 1-16,384 Hz, was applied through the electrodes, and the result recorded by a DAQ system. SEMG signals were recorded at 1000 Hz during isometric dorsiflexion contractions of 30 s, performed every 15 min for 2 h. Impedance data were acquired at 65,536 Hz immediately before and after SEMG recordings. Large individual differences in impedance levels were observed at low frequencies. At high frequencies, impedance values depended only on the electrode type. Impedance decreased steadily with time for Beckman electrodes (p < 0.05), but did not decrease significantly for Red Dot electrodes. The magnitude of the reduction over time varied widely between individuals, and was related to the initial impedance values. The impedance-bandwidth product remained constant for each electrode type (95% confidence intervals 146.2-148.2 and 126.1-127.8 for Beckman and Red Dot electrodes respectively). When skin impedance is electrically modelled with a simple network containing a resistor and a capacitor, the capacitance varies with the properties of the electrode used, whereas resistance is dependent on the subject. Furthermore, the EMG spectrum is unaffected by impedance provided skin preparation is sufficient to reduce the impedance below 55 komega.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The impedance at the electrode-skin interface is largely variable between individuals at low frequencies, whereas at high frequencies the decline of impedance values with time depends on the electrode type”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Hewson et al., 2003
Citations
Cites
Tabachnick, B. G., & Fidell, L. S. (1983) · Cited by 80,031
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Myoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 1,097
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Kaplan, E. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00031 · Cited by 589
Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts
Bigland-Ritchie, B., Donovan, E. F., & Roussos, C. S. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.5.1300 · Cited by 447
Muscular endurance and surface electromyogram in isometric and dynamic exercise
Hagberg, M. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.1.1 · Cited by 316
Duchêne, J., & Goubel, F. (1993) · PubMed · Cited by 178
Self-citationElectromyography and the study of sports movements: A review
Clarys, J. P., & Cabri, J. (1993) · Journal of Sports Sciences · doi:10.1080/02640419308730010 · Cited by 158
Noise characteristics of stainless-steel surface electrodes
Godin, D. T., Parker, P. A., & Scott, R. N. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446089 · Cited by 69
Research works printed but not linked: 2
- De Luca, 1985, Myoelectric manifestations of localized muscular fatigue, Crit. Rev. Biomed. Eng, 11, 251
- Thomasset, 1962, Propriétés électriques des tissus biologiques: mesure de l’impédance en clinique, Lyon Médical, 21, 107
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“The impedance at the electrode–skin interface is largely variable between individuals at low frequencies, whereas at high frequencies the decline of impedance values with time depends on the electrode type (Hewson et al., 2003).”
BackgroundMerletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
“During long term recordings, drying of the gel, changes of the skin properties and of the electrolyte-skin interface may cause significant variations of the electrode–skin impedance (Hewson et al., 2003; Dozio et al., 2007; Hoffmann et al., 2006).”
BackgroundTutorial. Surface EMG detection, conditioning and pre-processing: Best practices
Merletti, R., & Cerone, G. L. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102440 · Cited by 233
Samuel, O. W., Zhou, H., Li, X., Wang, H., Zhang, H., Sangaiah, A. K., & Li, G. (2018) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2017.04.003 · Cited by 193
MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation
Driscoll, N., Erickson, B., Murphy, B. B., Richardson, A. G., Robbins, G., Apollo, N. V., Mentzelopoulos, G., Mathis, T., Hantanasirisakul, K., Bagga, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abf8629 · Cited by 180
Metadata
- Authors
- Hewson, D. J., Hogrel, J.-Y., Langeron, Y., & Duchêne, J.
- Affiliations
- Université de Technologie de Troyes (FR)
- Institut de Myologie (FR)
- Corresponding author
- Hewson, D.J.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2003-06
- Volume
- 13
- Issue
- 3
- Pages
- 273-279
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2070908442
- Cited by
- 99
- References
- 22
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 8 · 2019: 2 · 2018: 4 · 2017: 7 · 2016: 4 · 2015: 4 · 2014: 6 · 2013: 3 · 2012: 2
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Electromyography and Kinesiology (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- University of Bedfordshire Repository (University of Bedfordshire) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Keywords
- skin capacitance, skin resistance, tibialis anterior
- MeSH terms
- Adult, Electrodes, Electromyography, Female, Galvanic Skin Response, Humans, Leg, Male, Muscle Contraction, Electric Impedance, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evolution in impedance at the electrode‐skin interface of two types of surface EMG electrodes during long‐term recordings. https://app.cochat.ai/papers/10.1016/s1050-6411(02)00097-4
- The paper
- Hewson, D. J., Hogrel, J.-Y., Langeron, Y., & Duchêne, J. (2003). Evolution in impedance at the electrode‐skin interface of two types of surface EMG electrodes during long‐term recordings. Journal of Electromyography and Kinesiology. https://doi.org/10.1016/s1050-6411(02)00097-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.