New fluorescent probes for the measurement of cell membrane viscosity
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802 · cited 1×
“Furthermore, endothelial cells are able to sense £uid shear stress through the cell membrane [15] and e¡ect changes that serve to maintain a speci¢c level of £ow in blood vessels [16].”
BackgroundMobility measurement by analysis of fluorescence photobleaching recovery kinetics
Axelrod, D., Koppel, D. E., Schlessinger, J., Elson, E., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85755-4 · Cited by 2,714 · cited 1×
“To date, there are three dominant methods to measure membrane viscosity: (a) £uorescence recovery after photobleaching (FRAP), in which measurement of the diiusivity of a £uorophore in the membrane is related to membrane viscosity [ 17 ], (b) £uorescence anisotropy, in which the out-ofplane rotation of a £uorophore is…”
MethodFluidity parameters of lipid regions determined by fluorescence polarization
Shinitzky, M., & Barenholz, Y. (1978) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(78)90010-2 · Cited by 1,875 · cited 2×
“The ratio of emitted light parallel versus perpendicular to the plane of excitation is a nonlinear function of the viscosity [ 18 ].”
BackgroundMethodDie Viskositätsabhängigkeit der Fluoreszenzquantenausbeuten einiger Farbstoffsysteme
Förster, T., & Hoffmann, G. (1971) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1971.75.1_2.063 · Cited by 573
Shear stress induces spatial reorganization of the endothelial cell cytoskeleton
Galbraith, C. G., Skalak, R., & Chien, S. (1998) · Cell Motility and the Cytoskeleton · doi:10.1002/(sici)1097-0169(1998)40:4<317::aid-cm1>3.0.co;2-8 · Cited by 387 · cited 1×
“Both the cytoskeleton with its slow response to shear stress [28,29], and the cytoplasm, which slightly increases viscosity with shear stress [30], do not contribute to the signal measured, but provide a background £uorescence which reduces the measurement sensitivity.”
BackgroundFluid shear stress increases membrane fluidity in endothelial cells: a study with DCVJ fluorescence
Haidekker, M. A., L'Heureux, N., & Frangos, J. A. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.4.h1401 · Cited by 238 · cited 5×
“Membrane viscosity changes could be detected for £uid shear stress as low as 0.1 Pa, while DCVJ did not lead to statistically signi¢cant changes for shear stress values of 0.6 Pa and below [ 15 ].”
BackgroundMethodSelf-citationFluorescence probes for polymer free-volume
Loutfy, R. O. (1986) · Pure and Applied Chemistry · doi:10.1351/pac198658091239 · Cited by 221 · cited 2×
“1) rest upon its ability to lose excited state energy either by radiation or by intramolecular rotation, the ratio of which depends on the free volume of the microenvironment [20].”
BackgroundDeliconstantinos, G., Villiotou, V., & Stavrides, J. C. (1995) · Biochemical Pharmacology · doi:10.1016/0006-2952(95)00094-g · Cited by 192 · cited 1×
“In addition, variations in membrane viscosity are linked to a variety of diseases, such as atherosclerosis [6], cell malignancy [7], hypercholesterolemia [8] and diabetes [9,10].”
BackgroundParasassi, T., Di Stefano, M., Loiero, M., Ravagnan, G., & Gratton, E. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80852-5 · Cited by 191 · cited 1×
“In the latter category are included compounds such as 2-dimethylamino-6-lauroylnaphthalene, whose emission wavelength shifts with the viscosity of the medium [ 19 ] and 9-(dicyanovinyl)-julolidine (DCVJ, 1) with a viscosity-dependent £uorescence quantum yield.”
BackgroundNadiv, O., Shinitzky, M., Manu, H., Hecht, D., Roberts, C. T., LeRoith, D., & Zick, Y. (1994) · Biochemical Journal · doi:10.1042/bj2980443 · Cited by 168
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Fluorescent Analogs of Biomolecular Building Blocks: Design, Properties, and Applications
Sinkeldam, R. W., Greco, N. J., & Tor, Y. (2010) · Chemical Reviews · doi:10.1021/cr900301e · Cited by 837
Discerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Molecular rotors—fluorescent biosensors for viscosity and flow
Haidekker, M. A., & Theodorakis, E. A. (2007) · Org. Biomol. Chem. · doi:10.1039/b618415d · Cited by 638
Self-citationTime-resolved fluorescence microscopy
Suhling, K., French, P. M. W., & Phillips, D. (2005) · Photochemical & Photobiological Sciences · doi:10.1039/b412924p · Cited by 548
Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
Klymchenko, A. S., & Kreder, R. (2014) · Chemistry & Biology · doi:10.1016/j.chembiol.2013.11.009 · Cited by 514
G protein-coupled receptors sense fluid shear stress in endothelial cells
Chachisvilis, M., Zhang, Y.-L., & Frangos, J. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607224103 · Cited by 491
Self-citationAdvanced functional materials based on polyhedral oligomeric silsesquioxane (POSS)
Tanaka, K., & Chujo, Y. (2012) · J. Mater. Chem. · doi:10.1039/c1jm14231c · Cited by 489
Mapping viscosity in cells using molecular rotors
Kuimova, M. K. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41674c · Cited by 484
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Wang, L., Xiao, Y., Tian, W., & Deng, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311688g · Cited by 464
Environment-sensitive behavior of fluorescent molecular rotors
Haidekker, M. A., & Theodorakis, E. A. (2010) · Journal of Biological Engineering · doi:10.1186/1754-1611-4-11 · Cited by 429
Self-citationLindgren, M., Sörgjerd, K., & Hammarström, P. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.049700 · Cited by 349
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
A molecular rotor for measuring viscosity in plasma membranes of live cells
López-Duarte, I., Vu, T. T., Izquierdo, M. A., Bull, J. A., & Kuimova, M. K. (2014) · Chem. Commun. · doi:10.1039/c3cc47530a · Cited by 274
Fluorescent Molecular Rotors for Viscosity Sensors
Lee, S., Heo, J., Woo, H. C., Lee, J., Seo, Y. H., Lee, C., Kim, S., & Kwon, O. (2018) · Chemistry – A European Journal · doi:10.1002/chem.201801389 · Cited by 271
The shear stress of it all: the cell membrane and mechanochemical transduction
White, C. R., & Frangos, J. A. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2128 · Cited by 255
Self-citationMotion-induced change in emission (MICE) for developing fluorescent probes
Su, D., Teoh, C. L., Wang, L., Liu, X., & Chang, Y.-T. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00018a · Cited by 223
Yang, X., Sheng, W., Sun, G. Y., & Lee, J. C.-M. (2011) · Neurochemistry International · doi:10.1016/j.neuint.2010.12.004 · Cited by 202
“DHA protection effect in Ab-infused rats was associated with increased membrane fluidity (Hashimoto et al., 2006) which also provided oxidative stress resistance in hippocampal cells (Clement et al., 2010).”
BackgroundOsteocyte Mechanobiology and Pericellular Mechanics
Jacobs, C. R., Temiyasathit, S., & Castillo, A. B. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105302 · Cited by 197
Methods for Physical Characterization of Phase-Separated Bodies and Membrane-less Organelles
Mitrea, D. M., Chandra, B., Ferrolino, M. C., Gibbs, E. B., Tolbert, M., White, M. R., & Kriwacki, R. W. (2018) · Journal of Molecular Biology · doi:10.1016/j.jmb.2018.07.006 · Cited by 173
“Viscosity-sensitive fluorophores or molecular rotors have also been used to characterize the viscoelastic properties of cellular membranes [62, 63].”
Metadata
- Authors
- Haidekker, M. A., Ling, T., Anglo, M., Stevens, H. Y., Frangos, J. A., & Theodorakis, E. A.
- Venue
- Chemistry & Biology
- Publisher
- Elsevier BV
- Published
- 2001-02
- Volume
- 8
- Issue
- 2
- Pages
- 123-131
- ISSN
- 1074-5521 (ISSN-L)
- OpenAlex
- W2044137136
- Cited by
- 226
- References
- 23
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.