Micropatterning gradients and controlling surface densities of photoactivatable biomolecules on self-assembled monolayers of oligo(ethylene glycol) alkanethiolates
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Bioactive molecules that are covalently immobilized in patterns on surfaces have previously been used to control or study cell behavior such as adhesion, spreading, movement or differentiation. Photoimmobilization techniques can be used, however, to control not only the spatial pattern of molecular immobilization, termed the micropattern, but also the surface density of the molecules--a characteristic that has not been previously exploited. RESULTS: Oligopeptides containing the bioactive Arg-Gly-Asp cell-adhesion sequence were immobilized upon self-assembled monolayers of an oligo(ethylene glycol) alkanethiolate in patterns that were visualized and quantified by autoradiography. The amount and pattern of immobilized peptide were controlled by manipulating the exposure of the sample to a UV lamp or a laser beam. Patterns of peptides, including a density gradient, were used to control the location and number of adherent cells and also the cell shape. CONCLUSIONS: A photoimmobilization technique for decorating surfaces with micropatterns that consist of variable densities of bioactive molecules is described. The efficacy of the patterns for controlling cell adhesion and shape has been demonstrated. This technique is useful for the study of cell behavior on micropatterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453
Massia, S. P., & Hubbell, J. A. (1991) · The Journal of cell biology · doi:10.1083/jcb.114.5.1089 · Cited by 878
Benzophenone Photophores in Biochemistry
Dorman, G., & Prestwich, G. D. (1994) · Biochemistry · doi:10.1021/bi00185a001 · Cited by 860
Mrksich, M., & Whitesides, G. M. (1996) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.25.060196.000415 · Cited by 850
Labeling of proteins by reductive methylation using sodium cyanoborohydride.
Jentoft, N., & Dearborn, D. G. (1979) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)30016-9 · Cited by 771
Pale-Grosdemange, C., Simon, E. S., Prime, K. L., & Whitesides, G. M. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00001a002 · Cited by 673
Controlling cell interactions by micropatterning in co-cultures: Hepatocytes and 3T3 fibroblasts
Bhatia, S. N., Yarmush, M. L., & Toner, M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2<189::aid-jbm8>3.0.co;2-m · Cited by 547
Golden interfaces: The Surface of Self‐Assembled Monolayers
Delamarche, E., Michel, B., Biebuyck, H. A., & Gerber, C. (1996) · Advanced Materials · doi:10.1002/adma.19960080903 · Cited by 377
Growth cone guidance and neuron morphology on micropatterned laminin surfaces
Clark, P., Britland, S., & Connolly, P. (1993) · Journal of Cell Science · doi:10.1242/jcs.105.1.203 · Cited by 264
Iuliano, D. J., Saavedra, S. S., & Truskey, G. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270816 · Cited by 238
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Surface engineering approaches to micropattern surfaces for cell-based assays
Falconnet, D., Csucs, G., Michelle Grandin, H., & Textor, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.024 · Cited by 944
A photolabile hydrogel for guided three-dimensional cell growth and migration
Luo, Y., & Shoichet, M. S. (2004) · Nature Materials · doi:10.1038/nmat1092 · Cited by 801
Inkjet printing for high-throughput cell patterning
Roth, E. A., Xu, T., Das, M., Gregory, C., Hickman, J. J., & Boland, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.052 · Cited by 714
Microengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Using photolabile ligands in drug discovery and development
Dormán, G., & Prestwich, G. D. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01402-x · Cited by 425
Photolithographic patterning of polyethylene glycol hydrogels
Hahn, M. S., Taite, L. J., Moon, J. J., Rowland, M. C., Ruffino, K. A., & West, J. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.045 · Cited by 411
Fabrication of Gradient Hydrogels Using a Microfluidics/Photopolymerization Process
Burdick, J. A., Khademhosseini, A., & Langer, R. (2004) · Langmuir · doi:10.1021/la049298n · Cited by 374
Engineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Microfabricated elastomeric stencils for micropatterning cell cultures
Folch, A., Jo, B.-H., Hurtado, O., Beebe, D. J., & Toner, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<346::aid-jbm14>3.0.co;2-h · Cited by 354
Biological surface engineering: a simple system for cell pattern formation
Zhang, S., Yan, L., Altman, M., Lässle, M., Nugent, H., Frankel, F., Lauffenburger, D. A., Whitesides, G. M., & Rich, A. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00014-9 · Cited by 344
25th Anniversary Article: Supramolecular Materials for Regenerative Medicine
Boekhoven, J., & Stupp, S. I. (2014) · Advanced Materials · doi:10.1002/adma.201304606 · Cited by 328
Arnold, M., Hirschfeld-Warneken, V. C., Lohmüller, T., Heil, P., Blümmel, J., Cavalcanti-Adam, E. A., López-García, M., Walther, P., Kessler, H., Geiger, B., et al. (2008) · Nano Letters · doi:10.1021/nl801483w · Cited by 305
Amphiphilic peptides and their cross-disciplinary role as building blocks for nanoscience
Cavalli, S., Albericio, F., & Kros, A. (2010) · Chem. Soc. Rev. · doi:10.1039/b906701a · Cited by 248
ARXPS characterisation of plasma polymerised surface chemical gradients
Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., & Wright, A. (2006) · Surface and Interface Analysis · doi:10.1002/sia.2400 · Cited by 238
Surface engineering strategies for control of protein and cell interactions
Nath, N., Hyun, J., Ma, H., & Chilkoti, A. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.182 · Cited by 232
Immobilized concentration gradients of nerve growth factor guide neurite outgrowth
Kapur, T. A., & Shoichet, M. S. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10168 · Cited by 217
Light‐Triggered Bioactivity in Three Dimensions
Muraoka, T., Koh, C., Cui, H., & Stupp, S. I. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901524 · Cited by 202
Singh, M., Berkland, C., & Detamore, M. S. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0304 · Cited by 202
Dillmore, W. S., Yousaf, M. N., & Mrksich, M. (2004) · Langmuir · doi:10.1021/la049826v · Cited by 194
Biology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
Presentation of RGDS Epitopes on Self-Assembled Nanofibers of Branched Peptide Amphiphiles
Guler, M. O., Hsu, L., Soukasene, S., Harrington, D. A., Hulvat, J. F., & Stupp, S. I. (2006) · Biomacromolecules · doi:10.1021/bm060161g · Cited by 186
Tissue Engineering at the Micro-Scale
Bhatia, S. N., & Chen, C. S. (1999) · Biomedical Microdevices · doi:10.1023/a:1009949704750 · Cited by 177
What can surface chemistry do for cell biology?
Mrksich, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00362-9 · Cited by 172
Metadata
- Authors
- Herbert, C. B., McLernon, T. L., Hypolite, C. L., Adams, D. N., Pikus, L., Huang, C.-C., Fields, G. B., Letourneau, P. C., Distefano, M. D., & Hu, W.-S.
- Venue
- Chemistry & Biology
- Publisher
- Elsevier BV
- Published
- 1997-10
- Volume
- 4
- Issue
- 10
- Pages
- 731-737
- ISSN
- 1074-5521 (ISSN-L)
- OpenAlex
- W2092879516
- Cited by
- 165
- References
- 15
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.