Cited by 64Icing and De-icing TechnologiesHeat Transfer and OptimizationRefrigeration and Air Conditioning Technologies

Frost deposition in a parallel plate channel under laminar flow conditions

Lüer, Andreas, Beer, Hans·2000·International Journal of Thermal Sciences

Integrity signals

Registry

Crossref · 10.1016/s1290-0729(00)00193-8

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • At higher Reynolds numbers, the frost layer is almost homogeneous, with the leading edge thickness remaining near constant and the downstream height increasing.

    “Luer and Beer (2000) also observed that at higher Reynolds numbers, the frost layer is almost homogeneous, with the leading edge thickness remaining near constant and the downstream height increasing.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Luer and Beer (2000)

  • Existing frosting models have focused on predicting heat and mass transfer characteristics at surfaces of basic geometries such as a flat plate or cylindrical surface.

    “Existing frosting models have focused on predicting the characteristics of heat and mass transfer at the surfaces of basic geometries, such as a flat plate or cylindrical surface [1-12].”
  • Reliance on homogenized surface roughness resulted in an average 22.52% deviation in frost thickness.

    “Nonetheless, reliance on homogenized surface roughness resulted in an average 22.52% deviation in frost thickness.”
  • The frost-growth stage is of particular significance because it governs the structural and thermophysical properties of the frost layer.

    “Among these, the frost-growth stage is of particular significance because it governs the structural and thermophysical properties of the frost layer [23 -26].”
  • Water-vapor transport through a porous medium is mainly due to Fickian diffusion caused by the gradient of the vapor partial pressure.

    “Previous researchers assumed that the water-vapor at the frost surface is saturated with the surface temperature, and water-vapor transport through a porous medium is mainly due to Fickian diffusion caused by the gradient of the vapor partial pressure [4,11,13,14].”

Cited by

Sorted by citations

Authors
Lüer, A., & Beer, H.
Affiliations
Technische Universität Darmstadt (DE)
Corresponding author
Beer, Hans
Venue
International Journal of Thermal Sciences
Publisher
Elsevier BV
Published
2000-01
Volume
39
Issue
1
Pages
85-95
ISSN
1290-0729 (ISSN-L)
OpenAlex
W2009212526
Cited by
64
References
0
Citations by year
2026: 4 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 5 · 2020: 3 · 2019: 3 · 2018: 4 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 2
FWCI
6.11
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Thermal Sciences (publishedVersion)
  • TUbilio (Technical University of Darmstadt) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
frost formation, frost layer growth, parallel plate channel, laminar forced convection, heat and mass transfer, frost thickness, air humidity, air velocity, plate temperature, two-phase model

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review