The DOI matches its Crossref record.
Development of a lightweight and adaptable multiple-axis hand prosthesis
Abstract
The last few decades have produced significant improvements in the design of upper limb prostheses through the increasing use of technology. However the limited function exhibited by these devices remains rooted in their single degree of freedom format. Commercial myoelectric hand prostheses warrant high grip forces to ensure stable prehension due to a planar pincer movement. Hence precise and conscious effort is required on the part of the user to ensure optimum grip. Consumers have shown dissatisfaction with the status quo due to the excessive weight and poor function of existing artificial hands. Increasing the number of grasping patterns and improving the visual feedback from an object in the hand are cited as key objectives. This paper outlines the development of the six-axis Southampton-Remedi hand prosthesis that addresses these design issues by maintaining stable prehension with minimal grip force. Constraints such as modularity, anthropomorphism, and low weight and power consumption are factors that have been adhered to throughout the design process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 2
- Kyberd, 1997, The population of users of upper limb prostheses attending the Oxford limb fitting service, 21, 85
- Light, 1999, Critical Review of Functionality Assessment in Natural and Prosthetic Hands, 62, 7
Cited by
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033113 · Cited by 204
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Metadata
- Authors
- Light, C. M., & Chappell, P. H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2000-12-01
- Volume
- 22
- Issue
- 10
- Pages
- 679-684
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2102315070
- Cited by
- 178
- References
- 0
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 144 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 144 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a lightweight and adaptable multiple-axis hand prosthesis. https://app.cochat.ai/papers/10.1016/s1350-4533(01)00017-0
- The paper
- Light, C. M., & Chappell, P. H. (2000). Development of a lightweight and adaptable multiple-axis hand prosthesis. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(01)00017-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.