The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Automated three-dimensional finite element modelling of bone: a new method
Abstract
Three-dimensional finite element stress analysis of bone is a key to understanding bone remodelling, assessing fracture risk, and designing prostheses; however, the cost and complexity of predicting the stress field in bone with accuracy has precluded the routine use of this method. A new, automated method of generating patient-specific three-dimensional finite element models of bone is presented--it uses digital computed tomographic (CT) scan data to drive the geometry of the bone and to estimate its inhomogeneous material properties. Cubic elements of a user-specified size are automatically defined and then individually assigned the CT scan-derived material properties. The method is demonstrated by predicting the stress, stain, and strain energy in a human proximal femur in vivo. Three-dimensional loading conditions corresponding to the stance phase of gait were taken from the literature and applied to the model. Maximum principal compressive stresses of 8-23 MPa were computed for the medial femoral neck. Automated generation of additional finite element models with larger numbers of elements was used to verify convergence in strain energy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Changes in Trabecular Pattern of the Upper End of the Femur as an Index of Osteoporosis
SINGH, M., NAGRATH, A. R., & MAINI, P. S. (1970) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197052030-00005 · Cited by 1,151
Precise Measurement of Vertebral Mineral Content Using Computed Tomography
Cann, C. E., & Genant, H. K. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198008000-00018 · Cited by 540
A survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539
Bone Deformation Recorded in vivo from Strain Gauges Attached to the Human Tibial Shaft
Lanyon, L. E., Hampson, W. G. J., Goodship, A. E., & Shah, J. S. (1975) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677508989216 · Cited by 475
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
On the mathematical analysis of stress in the human femur
Rybicki, E. F., Simonen, F. A., & Weis, E. B. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90056-5 · Cited by 286
Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282
Three dimensional stress analysis of the human femur
Valliappan, S., Svensson, N. L., & Wood, R. D. (1977) · Computers in Biology and Medicine · doi:10.1016/0010-4825(77)90031-2 · Cited by 77
Fast Contour Detection Algorithm for High Precision Quantitative CT
Seitz, P., & Ruegsegger, P. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307627 · Cited by 46
Cited by
Application of finite element analysis in implant dentistry: A review of the literature
Geng, J.-P., Tan, K. B. C., & Liu, G.-R. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.115251 · Cited by 1,106
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Self-citationCrawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Metadata
- Authors
- Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1990-09-01
- Volume
- 12
- Issue
- 5
- Pages
- 389-397
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2103374920
- Cited by
- 383
- References
- 11
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated three-dimensional finite element modelling of bone: a new method. https://app.cochat.ai/papers/10.1016/0141-5425(90)90022-f
- The paper
- Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D. (1990). Automated three-dimensional finite element modelling of bone: a new method. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(90)90022-f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.