Estimating the effective Young's modulus of soft tissues from indentation tests—nonlinear finite element analysis of effects of friction and large deformation
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A nonlinear finite element model was developed to investigate the biomechanics of indentation, particularly the influence of friction and large deformation on the calculation of the effective Young's modulus from the cylindrical, flat-ended indentation test of soft tissues. A new kappa table was given for calculation of the effective Young's modulus to account for the effects of layered geometry with consideration of the larger deformation. The results indicate that the effect of friction on the calculation of Young's modulus becomes significant with a large aspect ratio and with a large Poisson's ratio. It is found that the factor kappa increases almost proportionally to the increase of the indentation depth, especially obvious with a larger Poisson's ratio v and a larger aspect ratio a/h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
A mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967
[Mechanical properties of living tissues].
Sato, M. (1986) · PubMed · Cited by 516
Biphasic indentation of articular cartilage—II. A numerical algorithm and an experimental study
Mow, V. C., Gibbs, M. C., Lai, W. M., Zhu, W. B., & Athanasiou, K. A. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90069-9 · Cited by 509
Mechanical characteristics of skin and underlying tissues in vivo
Bader, D. L., & Bowker, P. (1983) · Biomaterials · doi:10.1016/0142-9612(83)90033-9 · Cited by 202
Kempson, G. E., Freeman, M. A. R., & Swanson, S. A. V. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90030-3 · Cited by 192
Indentation tests of human articular cartilage
Hori, R. Y., & Mockros, L. F. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90012-9 · Cited by 191
Spilker, R. L., Suh, J. F., & Mow, V. C. (1992) · Journal of Biomechanical Engineering · doi:10.1115/1.2891371 · Cited by 166
Cited by
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
Korhonen, R. K., Laasanen, M. S., Töyräs, J., Rieppo, J., Hirvonen, J., Helminen, H. J., & Jurvelin, J. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00052-0 · Cited by 464
The soft mechanical signature of glial scars in the central nervous system
Moeendarbary, E., Weber, I. P., Sheridan, G. K., Koser, D. E., Soleman, S., Haenzi, B., Bradbury, E. J., Fawcett, J., & Franze, K. (2017) · Nature Communications · doi:10.1038/ncomms14787 · Cited by 406
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“In an axisymmetric model where a flat-ended, cylindrical indent is applied perpendicular to the surface of a soft tissue, the resulting indentation force can be used to estimate the elasticity of the tissue under investigation [33].”
MethodHuang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Self-citationMicroglial Piezo1 senses Aβ fibril stiffness to restrict Alzheimer’s disease
Hu, J., Chen, Q., Zhu, H., Hou, L., Liu, W., Yang, Q., Shen, H., Chai, G., Zhang, B., Chen, S., et al. (2023) · Neuron · doi:10.1016/j.neuron.2022.10.021 · Cited by 193
In Vivo Penetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer Scales
Sharp, A. A., Ortega, A. M., Restrepo, D., Curran-Everett, D., & Gall, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003261 · Cited by 157
“While the influences of friction and finite tissue thickness on modulus values calculated with such a model have been shown to increase as Poisson’s ratio and relative indentation depth (ratio of indentation depth to tissue thickness) increase, both have been shown to decrease as the aspect ratio (ratio of the indente…”
Metadata
- Authors
- Zhang, M., Zheng, Y. P., & Mak, A. F. T.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1997-09-01
- Volume
- 19
- Issue
- 6
- Pages
- 512-517
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2073761920
- Cited by
- 282
- References
- 8
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.