The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Material properties assignment to finite element models of bone structures: a new method
Abstract
Finite element analysis (FEA) is widely adopted to investigate the mechanical behaviour of bone structures. Computed tomography (CT) data are frequently used to generate FE models of bone. If properly calibrated, CT images are capable of providing accurate information about the bone morphology and tissue density. The aim of this work was to develop a special program able to read a CT data set as well as the FEA mesh generated from it, and to assign to each element of the mesh the material properties derived from the bone tissue density at the element location. The program was tested on phantom data sets and was adopted to evaluate the effects of the discrete description of the bone material properties. A three-dimensional FE model was generated automatically from a 16 bit CT data set of a distal femur acquired in vivo. The strain energy density (SED) was evaluated for each model element for increasing model complexity (number of different material cards assigned to the model). The computed SED were strongly dependent on the material mapping strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Cited by
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Self-citationTaddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
Self-citationValidation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Taddei, F., Pancanti, A., & Viceconti, M. (2004) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00138-3 · Cited by 274
Self-citationPeng, L., Bai, J., Zeng, X., & Zhou, Y. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.06.003 · Cited by 262
Metadata
- Authors
- Zannoni, C., Mantovani, R., & Viceconti, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1999-02-01
- Volume
- 20
- Issue
- 10
- Pages
- 735-740
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2022504758
- Cited by
- 210
- References
- 2
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Material properties assignment to finite element models of bone structures: a new method. https://app.cochat.ai/papers/10.1016/s1350-4533(98)00081-2
- The paper
- Zannoni, C., Mantovani, R., & Viceconti, M. (1999). Material properties assignment to finite element models of bone structures: a new method. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(98)00081-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.