Objective motor response onset detection in surface myoelectric signals
The DOI matches its Crossref record; 71 of the 77 references it cites were found in a registry or an index.
Abstract
Precise detection of discrete motor events like the onsets of voluntary muscle contractions is a prerequisite for various psychophysiological approaches in sensorimotor system analysis. In biomedical research and clinical diagnosis, motor events frequently are determined from surface electromyographic (SEMG) signals by some computerized detection algorithm. However, little is known about the reliability and accuracy of these methods, which frequently rely on intuitive and heuristic criteria. Therefore, the systematic approach to computerized detection of discrete motor events from SEMG signals presented by this paper fills a basic gap in EMG signal processing. Based upon a dynamic process model for the SEMG signal, a formal detection scheme is established which incorporates the essential processing modules common to the majority of algorithms. In addition, using concepts of statistically optimal change detection in random processes, a new model-based algorithm is presented which serves as a reference for optimum performance. The validity of this concept is demonstrated for the specific example of accurate detection of muscle activation onsets in rapid voluntary contractions; the estimation error (i.e., the deviation between estimated and "true" onset time) was evaluated by statistical simulations for three representative methods. Results show a substantial decrease of performance of traditional methods in the case of highly variable dynamic muscle activation profiles and/or superimposed activation patterns (e.g., due to a secondary motor task simultaneously executed by the same muscle). The model-based approach provided significantly more accurate results, even when the exact model parameters were unknown but estimated from the SEMG signal actually measured. It is concluded that the detection algorithm has to be critically taken into consideration during interpretation of motor events resolved from SEMG signals. The process model together with the corresponding statistically optimal detector represents an efficient tool for selecting appropriate detection algorithms for a particular experimental condition, and it allows a quantitative assessment of their performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A wholly different approach involves systematic manual/visual identification of the actual instant of force onset. Whilst this approach appears to provide good validity (Tillin et al. 2013b), the potential influence of subjectivity could compromise its reliability (Staude and Wolf 1999), and it is undoubtedly less time efficient than automated methods.”
From Rate of force development: physiological and methodological considerations (2016) · cites this paper as Staude and Wolf 1999
Citations
Cites
PAGE, E. S. (1954) · Biometrika · doi:10.1093/biomet/41.1-2.100 · Cited by 5,739
Söderström, T., & Stoica, P. (1988) · Cited by 5,162
Detection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
An Introduction to Signal Detection and Estimation
Poor, H. V. (1988) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4757-3863-6 · Cited by 3,149
Economic Control of Quality of Manufactured Product.
Hotelling, H., & Shewhart, W. A. (1932) · Journal of the American Statistical Association · doi:10.2307/2277676 · Cited by 3,070
Procedures for Reacting to a Change in Distribution
Lorden, G. (1971) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177693055 · Cited by 1,351
Detection of Abrupt Changes: Theory and Application
Riedel, K. S., Basseville, M., Nikiforov, I. V., et al. (1994) · Technometrics · doi:10.2307/1269388 · Cited by 1,330
Economic control of quality of manufactured product
Elkinton, H. W. (1932) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(32)91043-6 · Cited by 1,247
Quality Control and Industrial Statistics.
Lave, R. E., & Duncan, A. J. (1967) · Journal of the American Statistical Association · doi:10.2307/2282940 · Cited by 1,001
Hodges, P. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95190-5 · Cited by 983
Cited by
Items 201–260 of 260
Elektromiyogram sinyallerinin sınıflandırılması ve bağımsız bileşen analizi ile işlenmesi
Başpınar, U. (2014) · Dspace Repository (Marmara Üniversitesi) · Cited by 2
Procesamiento de señales aplicado a dispositivos de ayuda para personas con discapacidades motoras
Haberman, M. (2016) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/53022 · Cited by 3
Pequera, G. (2015) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 2
Stensdotter, A. (2005) · DiVA at Umeå University (Umeå University) · Cited by 2
Valadão, P. F., Graciès, J., Cenni, F., Bar‐On, L., Piitulainen, H., Avela, J., & Finni, T. J. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00965.2024 · Cited by 2
Le, H., Spinks, G. M., Panhuis, M. I. H., & Alıcı, G. (2025) · IEEE International Conference on Mechatronics (ICM) · doi:10.1109/icm62621.2025.10934867 · Cited by 2
Ostojić, S., Srhoj-Egekher, V., Peharec, S., & Cifrek, M. (2018) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro.2018.8400046 · Cited by 2
sEMG onset detection caused by Temperature Variation
Herrera, E. V., Vela, E. M., Sanchez, N., Arce, V. A., Molina, K. G., Herrera, L. E., & Plaza, D. A. (2019) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit.2019.8820573 · Cited by 2
Temperature Influences at the Myoelectric Level in the Upper Extremities of the Human Body
Herrera, E. V., Vela, E. M., Arce, V. A., Molina, K. G., Sanchez, N., Daza, P. J., Herrera, L. E., & Plaza, D. A. (2020) · The Open Biomedical Engineering Journal · doi:10.2174/1874120702014010028 · Cited by 2
Electromyography and inertial sensor-based gesture detection and control
Freixo, R. A. E. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/xy2t-2v11 · Cited by 2
High-speed Low-consumption sEMG-based Transient-state micro-Gesture RecognitionPreprint
Han, Y., Zhao, W., Chen, X., & Meng, X. (2024) · arXiv (Cornell University) · Cited by 2
Metode za avtomatsko obdelavo elektromiografskih signalov mišic človeškega trupa
Panjan, A. (2017) · Repository of the University of Primorsk (University of Primorska) · Cited by 1
Mika, A., Oleksy, Ł., Mikołajczyk, E., & Marchewka, A. (2011) · European Journal of Clinical and Experimental Medicine · Cited by 1
Probabilistic onset detection based on multiple strides
Wambacq, H., Desloovere, K., Bar‐On, L., Aertbeliën, E., & Bruyninckx, H. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.07.107 · Cited by 1
Avaliação de marcha e postura em reabilitação
da Silva, A. F. F. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/94kt-jq44 · Cited by 1
Schillebeeckx, F., Hanssen, B., Beukelaer, N. D., Craenen, K., Verheyden, G., Peers, K., & Desloovere, K. (2026) · Scientific Reports · doi:10.1038/s41598-026-38551-2 · Cited by 1
Bervet, K. (2012) · theses.fr (ABES) · doi:10.70675/7297edf0zeee4z437bz9a27zcca254f27d25 · Cited by 1
The assessment of hip abductor activity using ultrasound imaging
Dieterich, A. V. (2013) · eSpace (Curtin University) · Cited by 1
Tarata, M. T., Şerbănescu, M.-S., Georgescu, D., Alexandru, D., & Wolf, W. (2016) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-32703-7_10 · Cited by 1
Self-citationHow Has Electromyography Been Used to Assess Reaching in Infants? A Systematic Review
da Fonseca, M. V., Oliveira, A. L. D. S., Figueiredo, R. D. M., Lima, R. T. F., & de Toledo, A. M. (2020) · Journal of Motor Behavior · doi:10.1080/00222895.2020.1723476 · Cited by 1
Advanced EMG analysis during gait: The probability of onset deviation index
Wambacq, H., Aertbeliën, E., Bar‐On, L., Desloovere, K., Nieuwenhuys, A., & Guy, M. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.04.048 · Cited by 1
Experimentelle Untersuchungen zur Optimierung der Belastungsmethodik im Schnellkrafttraining
Stutzig, N. P. (2009) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · Cited by 1
Automatic signal and image-based assessments of spinal cord injury and treatments.
Mesbah, S. (2019) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/3174
Interindividual Neuromuscular Characteristics and Their Relationships to Running Economy
Schornstein, B. J. (2017) · Scholarship & Creative Works - Digital UNC a service of University Libraries (University of Northern Colorado)
Kalkman, B. (2018) · Liverpool John Moores University · doi:10.24377/ljmu.t.00008836
Tillin, N. A. (2011) · Loughborough University Institutional Repository (Loughborough University)
Greene, R. (2019) · Memorial University Research Repository (Memorial University)
EEG Signal Synchronization Patterns During Hand Laterality Judgment Task
Ferreira, S. K. D. S., de Souza, R. F. L., Silveira, A. D. S., & Pereira, A. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49404-8_2
Hanna, F. (2009) · TSpace (University of Toronto)
Consolado, C. C. (2024) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Schillebeeckx, F. (2025) · Lirias
Zadeh, H. G. (2016) · Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia)
Online EMG onset detection during sit-to-stand motion using the time derivative of sample entropy
Scherrer, L., Kheddar, A., Desmyttere, G., Dusfour, G., Jørgensen, C., & Ramdani, S. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-02074-8
Cobian, D. G., Yack, H. J., Peterson, A. R., Williams, G. N., Shields, R. K., & Amendola, A. S. (2015) · doi:10.17077/etd.kurcas9z
Comparisons Between Movement Onset Identification Methods Used in Isometric Mid-Thigh Pull Test
Liu, J. (2018) · Digital Commons - East Tennessee State University (East Tennessee State University)
Towards mechanomyographic control of multifunction upper-limb prostheses
Alves, N. (2006) · TSpace (University of Toronto)
Eye and body movement strategies during turning tasks in older adults at risk of falls
Stretton, T. (2010) · Tuwhera (Auckland University of Technology)
Anticipatory lower limb muscle activity during a turning task
Ngan-Hing, L. (2006) · Tuwhera (Auckland University of Technology)
Aggarwal, A., (PT), H., (PT), S. C., Gupta, V., (PT), G. H., & (PT), G. S. (2025) · PAIN JOINTS SPINE · doi:10.1922/pjs.15.4.2025.1249
Rhou, B. (2010) · PolyPublie (École Polytechnique de Montréal)
Elektromyographische Analyse der Halsmuskulatur bei einer simulierten Heckkollision
Raven, M., & Margarethe, A. (2015) · Common Library Network (Der Gemeinsame Bibliotheksverbund)
Desloovere, K., Wambacq, H., Bastiaensen, A., de Walle, P. V., Bar‐On, L., Huenaerts, C., Campenhout, A. V., Aertbeliën, E., & Molenaers, G. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.07.106
직업성 만성요통 환자와 정상성인에서 동요 유발 시 근 수축 개시시간 비교
노경선, 권오윤, 이충휘, & 전혜선 (2007) · YUHSpace (Yonsei University Medical Library)
Biomechanical Response of Trunk Under Perturbations and in Challenged Seated Balance
Shahvarpour, A. (2015) · PolyPublie (École Polytechnique de Montréal)
Tarata, M. T., Şerbănescu, M.-S., Georgescu, D., Alexandru, D., & Wolf, W. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-52875-5_40
Self-citationTosin, M. C. (2018) · Americanae (AECID Library)
Evaluation of the trunk biomechanical responses to seated whole-body vibration exposure
Santos, B. R. (2009) · PolyPublie (École Polytechnique de Montréal)
Automatically Prepared for Landing: Reflexive Tuning of Limb Muscle Force to Impact IntensityPreprint
Konow, N., & Roberts, T. J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4579915
Ma, Y., Liang, S., & Chen, Z. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2404.11383
Fice, J. B., Foulger, L. H., Mang, D. W. H., Blouin, J., & Siegmund, G. P. (2025) · Annals of Biomedical Engineering · doi:10.1007/s10439-025-03926-5
Shepherd, K. (2024) · cIRcle (University of British Columbia) · doi:10.14288/1.0440938
Falisse, A. M. D. (2019) · Lirias
Application of Singular Spectrum-based Change-point Analysis to EMG Event Detection
Vaisman, L. (2008) · TSpace (University of Toronto)
Interactie tussen spier-pees morfologie, neuromotorische symptomen en gang in cerebrale parese
Schless, S. (2018) · Lirias
Vacuum-Assisted Closure and Nursing Care
Mbatha, P. B. S. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1012531
Plamondon, A., Larivière, C., Arjmand, N., Gagnon, D., Ouaaid, Z. E., Shahvarpour, A., & Shirazi-Adl, A. (2015) · PhareSST · doi:10.70010/zwbw4210
Metadata
- Authors
- Staude, G., & Wolf, W.
- Affiliations
- Universität der Bundeswehr München (DE)
- Corresponding author
- Staude, G.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1999-07-01
- Volume
- 21
- Issue
- 6
- Pages
- 449-467
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2043716521
- Semantic Scholar
- be079ed1cd5427dec6e2e02fe34155d65c08fed5
- Cited by
- 217
- References
- 77
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 4 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 13 · 2019: 10 · 2018: 13 · 2017: 15 · 2016: 13 · 2015: 11 · 2014: 15 · 2013: 11 · 2012: 16
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 144 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 144 d)
- Locations
- Medical Engineering & Physics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Keywords
- muscle activation onset, surface electromyography, EMG signal processing, change detection, dynamic process model, detection accuracy
- MeSH terms
- Algorithms, Electromyography, Humans, Models, Neurological, Motor Neurons, Muscle Contraction, Muscles, Signal Processing, Computer-Assisted, Stochastic Processes, Surface Properties, Time Factors, Reproducibility of Results, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.