Objective motor response onset detection in surface myoelectric signals
The DOI matches its Crossref record; 71 of the 77 references it cites were found in a registry or an index.
Abstract
Precise detection of discrete motor events like the onsets of voluntary muscle contractions is a prerequisite for various psychophysiological approaches in sensorimotor system analysis. In biomedical research and clinical diagnosis, motor events frequently are determined from surface electromyographic (SEMG) signals by some computerized detection algorithm. However, little is known about the reliability and accuracy of these methods, which frequently rely on intuitive and heuristic criteria. Therefore, the systematic approach to computerized detection of discrete motor events from SEMG signals presented by this paper fills a basic gap in EMG signal processing. Based upon a dynamic process model for the SEMG signal, a formal detection scheme is established which incorporates the essential processing modules common to the majority of algorithms. In addition, using concepts of statistically optimal change detection in random processes, a new model-based algorithm is presented which serves as a reference for optimum performance. The validity of this concept is demonstrated for the specific example of accurate detection of muscle activation onsets in rapid voluntary contractions; the estimation error (i.e., the deviation between estimated and "true" onset time) was evaluated by statistical simulations for three representative methods. Results show a substantial decrease of performance of traditional methods in the case of highly variable dynamic muscle activation profiles and/or superimposed activation patterns (e.g., due to a secondary motor task simultaneously executed by the same muscle). The model-based approach provided significantly more accurate results, even when the exact model parameters were unknown but estimated from the SEMG signal actually measured. It is concluded that the detection algorithm has to be critically taken into consideration during interpretation of motor events resolved from SEMG signals. The process model together with the corresponding statistically optimal detector represents an efficient tool for selecting appropriate detection algorithms for a particular experimental condition, and it allows a quantitative assessment of their performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A wholly different approach involves systematic manual/visual identification of the actual instant of force onset. Whilst this approach appears to provide good validity (Tillin et al. 2013b), the potential influence of subjectivity could compromise its reliability (Staude and Wolf 1999), and it is undoubtedly less time efficient than automated methods.”
From Rate of force development: physiological and methodological considerations (2016) · cites this paper as Staude and Wolf 1999
Citations
Cites
PAGE, E. S. (1954) · Biometrika · doi:10.1093/biomet/41.1-2.100 · Cited by 5,739
Söderström, T., & Stoica, P. (1988) · Cited by 5,162
Detection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
An Introduction to Signal Detection and Estimation
Poor, H. V. (1988) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4757-3863-6 · Cited by 3,149
Economic Control of Quality of Manufactured Product.
Hotelling, H., & Shewhart, W. A. (1932) · Journal of the American Statistical Association · doi:10.2307/2277676 · Cited by 3,070
Procedures for Reacting to a Change in Distribution
Lorden, G. (1971) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177693055 · Cited by 1,351
Detection of Abrupt Changes: Theory and Application
Riedel, K. S., Basseville, M., Nikiforov, I. V., et al. (1994) · Technometrics · doi:10.2307/1269388 · Cited by 1,330
Economic control of quality of manufactured product
Elkinton, H. W. (1932) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(32)91043-6 · Cited by 1,247
Quality Control and Industrial Statistics.
Lave, R. E., & Duncan, A. J. (1967) · Journal of the American Statistical Association · doi:10.2307/2282940 · Cited by 1,001
Hodges, P. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95190-5 · Cited by 983
A generalized likelihood ratio approach to the detection and estimation of jumps in linear systems
Willsky, A., & Jones, H. (1976) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1976.1101146 · Cited by 875
Fuzzy models for pattern recognition
Bezdek, J. C., & Pal, S. K. (1994) · Cited by 832
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Yuen, C. K., & Fraser, D. A. (1975) · CERN Document Server (European Organization for Nuclear Research) · Cited by 570
Balakrishnan, A. V. (1973) · Lecture Notes in Economics and Mathematical Systems · doi:10.1007/978-3-642-80759-6_8 · Cited by 555
A sequence of postural movements precedes voluntary movement
Bouisset, S., & Zattara, M. (1981) · Neuroscience Letters · doi:10.1016/0304-3940(81)90117-8 · Cited by 508
Inference about the change-point from cumulative sum tests
HINKLEY, D. V. (1971) · Biometrika · doi:10.1093/biomet/58.3.509 · Cited by 460
Nashner, L. M., Shumway-Cook, A., & Marin, O. (1983) · Experimental Brain Research · doi:10.1007/bf00238781 · Cited by 396
Kroupa, V. (1983) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1983.1164005 · Cited by 378
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375
Quality Control and Industrial Statistics.
M., R. H., & Duncan, A. J. (1975) · Journal of the American Statistical Association · doi:10.2307/2285861 · Cited by 358
Reliability of Computerized Surface Electromyography for Determining the Onset of Muscle Activity
Di Fabio, R. P. (1987) · Physical Therapy · doi:10.1093/ptj/67.1.43 · Cited by 278
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326652 · Cited by 241
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
Decision Theoretic Optimality of the Cusum Procedure
Ritov, Y. (1990) · The Annals of Statistics · doi:10.1214/aos/1176347761 · Cited by 221
Myoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 203
Adaptive sequential segmentation of piecewise stationary time series
Appel, U., & Brandt, A. V. (1983) · Information Sciences · doi:10.1016/0020-0255(83)90008-7 · Cited by 195
Studenski, S., Duncan, P. W., & Chandler, J. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01642.x · Cited by 188
Reaction times and attention in Parkinson's disease.
Bloxham, C. A., Dick, D. J., & Moore, M. (1987) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.50.9.1178 · Cited by 163
Abnormal most-rapid isometric contractions in patients with Parkinson's disease.
Wierzbicka, M. M., Wiegner, A. W., Logigian, E. L., & Young, R. R. (1991) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.54.3.210 · Cited by 133
Detection of EMG onset in ERP research
VAN BOXTEL, G. J. M., GERAATS, L. H. D., VAN DEN BERG‐LENSSEN, M. M. C., & BRUNIA, C. H. M. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02062.x · Cited by 131
Wilson, R., Calway, A. D., & Pearson, E. R. S. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119730 · Cited by 126
Hefftner, G., Zucchini, W., & Jaros, G. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1370 · Cited by 118
Badke, M. B., & Duncan, P. W. (1983) · Physical Therapy · doi:10.1093/ptj/63.1.13 · Cited by 118
Objective response detection in the frequency domain
Dobie, R. A., & Wilson, M. J. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90040-v · Cited by 111
Autoregressive Modeling of Surface EMG and Its Spectrum with Application to Fatigue
Paiss, O., & Inbar, G. F. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325918 · Cited by 108
Barrett, G., Shibasaki, H., & Neshige, R. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)90042-2 · Cited by 96
Adamovich, S. V., Levin, M. F., & Feldman, A. G. (1994) · Experimental Brain Research · doi:10.1007/bf00239599 · Cited by 94
Programming and execution of sequential movements in Parkinson's disease.
Rafal, R. D., Inhoff, A. W., Friedman, J. H., & Bernstein, E. (1987) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.50.10.1267 · Cited by 85
Fast voluntary trunk flexion movements in standing: motor patterns
ODDSSON, L., & THORSTENSSON, A. (1987) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1987.tb08044.x · Cited by 84
Wavelet representations of stochastic processes and multiresolution stochastic models
Dijkerman, R. W., & Mazumdar, R. R. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.298272 · Cited by 83
Fatigue compensation of the electromyographic signal for prosthetic control and force estimation
Park, E., & Meek, S. G. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247800 · Cited by 79
A fuzzy set theoretical approach to automatic analysis of nystagmic eye movements
Arzi, M., & Magnin, M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.35304 · Cited by 63
Weitkunat, R. (1991) · Elsevier eBooks · Cited by 59
Burgess, R. C. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90140-d · Cited by 59
Temporal quantification of electromyography with reference to motor control research
Walter, C. B. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90009-5 · Cited by 55
Lidierth, M. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90163-x · Cited by 47
Relationship between tremor and the onset of rapid voluntary contraction in Parkinson's disease.
Wierzbicka, M. M., Staude, G., Wolf, W., & Dengler, R. (1993) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.56.7.782 · Cited by 43
Self-citationComputer-Aided Determination of the Silent Period
Nilsson, J., Panizza, M. E., & Arieti, P. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199703000-00006 · Cited by 39
Tremor as a factor in prolonged reaction times of Parkinsonian patients
Staude, G., Wolf, W., Ott, M., Oertel, W. H., & Dengler, R. (1995) · Movement Disorders · doi:10.1002/mds.870100205 · Cited by 39
Self-citationUsing the discrete wavelet transform for time-frequency analysis of the surface EMG signal.
Constable, R., & Thornhill, R. J. (1993) · PubMed · Cited by 38
Multiresolution biological transient extraction applied to respiratory crackles
Sankur, B., Güler, E. Ç., & Kahya, Y. P. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00025-9 · Cited by 36
Role of motor performance in cognitive processes of parkinsonian patients
Girotti, F., Soliveri, P., Carella, F., Geminiani, G. C., Aiello, G., & CARACENI, T. (1988) · Neurology · doi:10.1212/wnl.38.4.537 · Cited by 31
Reaction times recording methods: reliability and EMG analysis of patterns of motor commands
Tomberg, C., Levarlet-Joye, H., & Desmedt, J. E. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90013-n · Cited by 30
Svensson, O. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247809 · Cited by 28
Seroussi, R. E., Krag, M. H., Wilder, P. A., & Pope, M. H. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16476 · Cited by 27
Electromyographic Study of Muscular Overflow During Precision Handgrip
Carey, J. R., Allison, J. D., & Mundale, M. O. (1983) · Physical Therapy · doi:10.1093/ptj/63.4.505 · Cited by 26
Fractioned reaction time as a function of response force
Haagh, S. A. V. M., Spijkers, W., van den Bogaart, B., & Boxtel, A. V. (1987) · Acta Psychologica · doi:10.1016/0001-6918(87)90016-3 · Cited by 25
Fractionated Reaction Time and the Rate of Force Development
Siegel, D. S. (1988) · The Quarterly Journal of Experimental Psychology Section A · doi:10.1080/02724988843000078 · Cited by 23
Onset and offset of electromyographic (EMG) silence in asterixis.
Ugawa, Y., Genba, K., Shimpo, T., & Mannen, T. (1990) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.3.260 · Cited by 15
Neural network classification of myoelectric signal for prosthesis control
Kelly, M. F., Parker, P. A., & Scott, R. N. (1991) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(91)90009-t · Cited by 13
Takada, K., Nagata, M., Miyawaki, S., Kuriyama, R., Yasuda, Y., & Sakuda, M. (1992) · PubMed · Cited by 12
Multiresolution segmentation of respiratory electromyographic signals
Choi, H. S., Príncipe, J. C., Hutchison, A. A., & Woźniak, J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284944 · Cited by 11
Automatic event detection in surface EMG of rhythmically activated muscles
Staude, G., Wolf, W., & Appel, U. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579722 · Cited by 11
Self-citationSignal processing for event detection
Ahlbom, L., Forsen, A., & Zetterberg, L. H. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1982.1171825 · Cited by 7
On-line estimation of myoelectric signal spectral parameters and nonstationarities detection
D’Alessio, T., Knaflitz, M., Balestra, G., & Paggi, S. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.245620 · Cited by 7
Hsia, P.-W., Jolly, S., & Mahmud, R. (2003) · Computers in cardiology · doi:10.1109/cic.1988.72660 · Cited by 6
Real-time detection of precise EMG onset for synchronisation of an EEG averager
Greeley, H. P. (1984) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/5/1/003 · Cited by 6
Automatic measurement of on/off periods of EMG activity.
Takada, K., & Yashiro, K. (1995) · PubMed · Cited by 5
A dynamic generator model for motor-related biosignals
Staude, G., Flachenecker, C., & Wolf, W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.744782 · Cited by 4
Self-citationEnhanced onset detection accuracy "reduces" the electromechanical delay of distal muscles
Wolf, W., Staude, C., & Appel, U. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1994.411988 · Cited by 4
Self-citation
Cited by
Rate of force development: physiological and methodological considerations
Maffiuletti, N. A., Aagaard, P., Blazevich, A. J., Folland, J., Tillin, N., & Duchateau, J. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3346-6 · Cited by 1,424
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Hodges, P. W., van den Hoorn, W., Wrigley, T. V., Hinman, R. S., Bowles, K.-A., Cicuttini, F., Wang, Y., & Bennell, K. (2016) · Manual Therapy · doi:10.1016/j.math.2015.07.004 · Cited by 371
Metadata
- Authors
- Staude, G., & Wolf, W.
- Affiliations
- Universität der Bundeswehr München (DE)
- Corresponding author
- Staude, G.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1999-07-01
- Volume
- 21
- Issue
- 6
- Pages
- 449-467
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2043716521
- Cited by
- 217
- References
- 77
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 4 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 13 · 2019: 10 · 2018: 13 · 2017: 15 · 2016: 13 · 2015: 11 · 2014: 15 · 2013: 11 · 2012: 16
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 144 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 144 d)
- Locations
- Medical Engineering & Physics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Keywords
- muscle activation onset, surface electromyography, EMG signal processing, change detection, dynamic process model, detection accuracy
- MeSH terms
- Algorithms, Electromyography, Humans, Models, Neurological, Motor Neurons, Muscle Contraction, Muscles, Signal Processing, Computer-Assisted, Stochastic Processes, Surface Properties, Time Factors, Reproducibility of Results, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.