The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Measurements and modelling of the compliance of human and porcine organs
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strength of biological materials
Yamada, H., & Evans, F. G. (1970) · Cited by 1,136
Elasticity of soft tissues in simple elongation
Fung, Y. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.6.1532 · Cited by 1,029
Virtual reality surgical simulator: The first steps
Satava, R. M. (1993) · Surgical Endoscopy · doi:10.1007/bf00594110 · Cited by 557
A note on the elasticity of soft biological tissues
Demiray, H. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90047-4 · Cited by 416
Interactively deformable models for surgery simulation
Cover, S. A., Ezquerra, N. F., O'Brien, J. F., Rowe, R., Gadacz, T., & Palm, E. (1993) · IEEE Computer Graphics and Applications · doi:10.1109/38.252559 · Cited by 188
Karduna, A. R., Halperin, H. R., & Yin, F. C. P. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684136 · Cited by 43
Cited by
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Increased stiffness of the rat liver precedes matrix deposition: implications for fibrosis
Georges, P. C., Hui, J.-J., Gombos, Z., McCormick, M. E., Wang, A. Y., Uemura, M., Mick, R., Janmey, P. A., Furth, E. E., & Wells, R. G. (2007) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00032.2007 · Cited by 577
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
A Survey of Surgical Simulation: Applications, Technology, and Education
Liu, A., Tendick, F., Cleary, K., & Kaufmann, C. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322955905 · Cited by 279
Metadata
- Authors
- Carter, F. J., Frank, T. G., Davies, P. J., McLean, D., & Cuschieri, A.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 5
- Issue
- 4
- Pages
- 231-236
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2065068680
- Cited by
- 278
- References
- 6
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements and modelling of the compliance of human and porcine organs. https://app.cochat.ai/papers/10.1016/s1361-8415(01)00048-2
- The paper
- Carter, F. J., Frank, T. G., Davies, P. J., McLean, D., & Cuschieri, A. (2001). Measurements and modelling of the compliance of human and porcine organs. Medical Image Analysis. https://doi.org/10.1016/s1361-8415(01)00048-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.