Electrospray ionization mass spectrometry: a technology for studying noncovalent macromolecular complexes
The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Self-citationProbing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Detection of noncovalent receptor-ligand complexes by mass spectrometry
Ganem, B., Li, Y. T., & Henion, J. D. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00016a069 · Cited by 506
Katta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Coexisting stable conformations of gaseous protein ions.
Suckau, D., Shi, Y., Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.790 · Cited by 345
Cited by
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Schug, K. A., & Lindner, W. (2005) · Chemical Reviews · doi:10.1021/cr040603j · Cited by 579
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Ion mobility–mass spectrometry: a new paradigm for proteomics
McLean, J. A., Ruotolo, B. T., Gillig, K. J., & Russell, D. H. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.10.003 · Cited by 309
Mass spectrometry of peptides and proteins
Wysocki, V. H., Resing, K. A., Zhang, Q., & Cheng, G. (2005) · Methods · doi:10.1016/j.ymeth.2004.08.013 · Cited by 307
Native protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303
The Drosophila Nuclear Receptor E75 Contains Heme and Is Gas Responsive
Reinking, J., Lam, M. M. S., Pardee, K., Sampson, H. M., Liu, S., Yang, P., Williams, S., White, W., Lajoie, G., Edwards, A., et al. (2005) · Cell · doi:10.1016/j.cell.2005.07.005 · Cited by 259
Collisional Cooling of Large Ions in Electrospray Mass Spectrometry
Chernushevich, I. V., & Thomson, B. A. (2004) · Analytical Chemistry · doi:10.1021/ac035406j · Cited by 235
All-trans retinoic acid is a ligand for the orphan nuclear receptor RORβ
Stehlin-Gaon, C., Willmann, D., Zeyer, D., Sanglier, S., Van Dorsselaer, A., Renaud, J.-P., Moras, D., & Schüle, R. (2003) · Nature Structural & Molecular Biology · doi:10.1038/nsb979 · Cited by 231
“gif" NDATA ITEM> ]> The orphan nuclear subfamily NR1F is composed of the retinoic acid receptor–related orphan receptors RORα, β and γ (reviewed in ref”
BackgroundBacher, G., Szymanski, W. W., Kaufman, S. L., Zöllner, P., Blaas, D., & Allmaier, G. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.208 · Cited by 222
Tahallah, N., Pinkse, M., Maier, C. S., & Heck, A. J. R. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.275 · Cited by 210
Pongratz, M., Schluga, P., Jakupec, M. A., Arion, V. B., Hartinger, C. G., Allmaier, G., & Keppler, B. K. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b309160k · Cited by 206
Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
Loo, J. A., Berhane, B., Kaddis, C. S., Wooding, K. M., Xie, Y., Kaufman, S. L., & Chernushevich, I. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.017 · Cited by 203
“A number of very large protein complexes have been measured by ESI-MS [6, 8, 9].”
BackgroundSelf-citationSubunit Exchange of Multimeric Protein Complexes
Sobott, F., Benesch, J. L. P., Vierling, E., & Robinson, C. V. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m206060200 · Cited by 199
Konermann, L., Tong, X., & Pan, Y. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1435 · Cited by 197
Bourdenx, M., Koulakiotis, N. S., Sanoudou, D., Bezard, E., Dehay, B., & Tsarbopoulos, A. (2017) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2015.07.003 · Cited by 185
“These compounds, along with several novel hydroxytyrosol derivatives possessing structural analogy to oleuropein (OE), were screened for binding with Ab peptide employing electrospray ionization (ESI) MS (Ganguly et al., 2002; Loo, 2000).”
MethodSerine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04897 · Cited by 167
Protein‐folding kinetics and mechanisms studied by pulse‐labeling and mass spectrometry
Konermann, L., & Simmons, D. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10044 · Cited by 163
“…allows the observation of non-covalent interactions in solution by the direct detection of the corresponding complex ions in the mass spectrum (Katta & Chait, 1991b; Przybylski & Glocker, 1996; Potier et al., 1998; Loo, 2000; Rostom et al., 2000; Daniel et al., 2002; van den Bremer et al., 2002).”
BackgroundLeblanc, Y., Ramon, C., Bihoreau, N., & Chevreux, G. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.02.017 · Cited by 127
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Gavriilidou, A. F. M., Gülbakan, B., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02478 · Cited by 53
Native vs Denatured: An in Depth Investigation of Charge State and Isotope Distributions
Kafader, J. O., Melani, R. D., Schachner, L. F., Ives, A. N., Patrie, S. M., Kelleher, N. L., & Compton, P. D. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00040 · Cited by 51
Metadata
- Authors
- Loo, J. A.
- Venue
- International Journal of Mass Spectrometry
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 200
- Issue
- 1-3
- Pages
- 175-186
- ISSN
- 1387-3806 (ISSN-L)
- OpenAlex
- W2057461407
- Cited by
- 444
- References
- 57
- FWCI
- 11.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.