The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Epileptic source localization with high density EEG: how many electrodes are needed?
Abstract
Objective Electroencephalography (EEG) source reconstruction is becoming recognized as a useful technique to non-invasively localize the epileptic focus. Whereas, large array magnetoencephalography (MEG) systems are available since quite some time, application difficulties have previously prevented multichannel EEG recordings. Recently, however, EEG systems which allow for quick (10-20min) application of, and recording from, up to 125 electrodes have become available. The purpose of the current investigation was to systematically compare the accuracy of epileptic source localization with high electrode density to that obtained with sparser electrode setups.Methods Interictal epileptiform activity was recorded with 123 electrodes in 14 epileptic patients undergoing presurgical evaluation. Each single epileptiform potential was down sampled to 63 and 31 electrodes, and a distributed source model (EPIFOCUS) was used to reconstruct the sources with the 3 different electrode configurations. The localization accuracy with the 3 electrode setups was then assessed, by determining the distance from the inverse solution, maximum of each single spike to the epileptogenic lesion.Results In 9/14 patients, the distance from the EEG source to the lesion was significantly smaller with 63 than with 31 electrodes, and increasing the number of electrodes to 123 increased this number of patients from 9 to 11. Simulations confirmed the relation between the number of electrodes and localization accuracy.Conclusions The results illustrate the necessity of multichannel EEG recordings for high source location accuracy in epileptic patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Third, the analysis of EEG oscillations did not explore the relationships with brain structure as well as source analysis (Lantz et al. 2003).”
From Changes in Mental Health and EEG Biomarkers of Undergraduates Under Different Patterns of Mindfulness (2024) · cites this paper as Lantz et al. 2003
In the citing paper
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [18]
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of vibration and acoustics · doi:10.1115/1.3269865 · Cited by 6,401
Random data: Analysis and measurement procedures
Braun, S. (1987) · Mechanical Systems and Signal Processing · doi:10.1016/0888-3270(87)90088-4 · Cited by 2,371
Presurgical evaluation of epilepsy.
Rosenow, F., & Lüders, H. (2001) · Brain : a journal of neurology · doi:10.1093/brain/124.9.1683 · Cited by 1,684
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Menéndez, R. G. D. P., Andino, S. L. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 347
Self-citationLocation of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
A new interpretation of the generators of BAEP waves I-V: results of a spatio-temporal dipole model.
Scherg, M., & von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0168-5597(85)90006-1 · Cited by 308
Cited by
Sorted by citations
Items 101–200 of 414
Recommandations françaises sur l’électroencéphalogramme
André‐Obadia, N., Sauleau, P., Cheliout-Heraut, F., Convers, P., Debs, R., Eisermann, M., Gavaret, M., Isnard, J., Jung, J., Kamińska, A., et al. (2014) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2014.10.001 · Cited by 45
Automated long‐term EEG analysis to localize the epileptogenic zone
van Mierlo, P., Strobbe, G., Keereman, V., Birot, G., Gadeyne, S., Gschwind, M., Carrette, E., Meurs, A., Roost, D. V., Vonck, K. E. J., et al. (2017) · Epilepsia Open · doi:10.1002/epi4.12066 · Cited by 46
Self-citationNir, R., Lev, R., Moont, R., Granovsky, Y., Sprecher, E., & Yarnitsky, D. (2008) · Journal of Pain · doi:10.1016/j.jpain.2008.06.008 · Cited by 47
Zhang, C. H., Sha, Z., Mundahl, J., Liu, S., Lu, Y., Henry, T. R., & He, B. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.07.014 · Cited by 45
Malik, A. S., & Amin, H. U. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-811140-6.00001-1 · Cited by 45
Electroencephalography, magnetoencephalography and source localization: their value in epilepsy
Mégevand, P., & Seeck, M. (2018) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000545 · Cited by 45
Self-citationAlba, G., Vila, J., Solaz, B. R., Montoya, P., & Muñoz, M. Á. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00064 · Cited by 53
EEG source imaging of anterior temporal lobe spikes: Validity and reliability
Wennberg, R. A., & Cheyne, D. O. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.09.042 · Cited by 45
Extraversion and anterior vs. posterior DMN activity during self-referential thoughts
Knyazev, G. G. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00348 · Cited by 47
Automatic localization and labeling of EEG sensors (ALLES) in MRI volume
Koessler, L., Benhadid, A., Maillard, L. G., Vignal, J., Felblinger, J., Vespignani, H., & Braun, M. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.039 · Cited by 44
An Information-Theoretic View of EEG Sensing
Grover, P., & Venkatesh, P. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2615179 · Cited by 44
Evaluation of L1 and L2 minimum norm performances on EEG localizations
Silva, C., Maltez, J., Trindade, E. A., Arriaga, A., & Ducla‐Soares, E. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.009 · Cited by 43
Chowdhury, R., Pellegrino, G., Aydin, Ü., Lina, J., Dubeau, F., Kobayashi, E., & Grova, C. (2018) · Human Brain Mapping · doi:10.1002/hbm.23889 · Cited by 44
Singh, J., Ebersole, J. S., & Brinkmann, B. (2022) · Epilepsia · doi:10.1111/epi.17361 · Cited by 37
Ntolkeras, G., Tamilia, E., Alhilani, M., Bolton, J. B., Grant, P. E., Prabhu, S. P., Madsen, J. R., Stufflebeam, S. M., Pearl, P. L., & Papadelis, C. L. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.01.036 · Cited by 41
Functional connectivity analysis in EEG source space: The choice of method
Barzegaran, E., & Knyazeva, M. G. (2017) · PLoS ONE · doi:10.1371/journal.pone.0181105 · Cited by 45
Normative brain mapping using scalp EEG and potential clinical application
Janiukstyte, V., Owen, T. W., Chaudhary, U. J., Diehl, B., Lemieux, L., Duncan, J. S., de Tisi, J., Wang, Y., & Taylor, P. N. (2023) · Scientific Reports · doi:10.1038/s41598-023-39700-7 · Cited by 38
THE NEUROPHENOMENOLOGY OF OUT-OF-BODY EXPERIENCES INDUCED BY HYPNOTIC SUGGESTIONS
Facco, E., Casiglia, E., Khafaji, B. E. A., Finatti, F., Duma, G. M., Mento, G., Pederzoli, L., & Tressoldi, P. E. (2019) · International Journal of Clinical and Experimental Hypnosis · doi:10.1080/00207144.2019.1553762 · Cited by 44
Yokoyama, H., Kaneko, N., Masugi, Y., Ogawa, T., Watanabe, K., & Nakazawa, K. (2020) · European Journal of Neuroscience · doi:10.1111/ejn.14867 · Cited by 38
High-resolution EEG: Cortical potential imaging of interictal spikes
Zhang, X., van Drongelen, W., Hecox, K. E., Towle, V. L., Frim, D. M., McGee, A., & He, B. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00194-9 · Cited by 38
Aarabi, A., Kazemi, K., Grebe, R., Moghaddam, H. A., & Wallois, F. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.057 · Cited by 37
Lateralization and localization of epilepsy related hemodynamic foci using presurgical fMRI
Zhang, C. H., Lu, Y., Brinkmann, B. H., Welker, K. M., Worrell, G. A., & He, B. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.04.011 · Cited by 37
van Dinteren, R., Huster, R. J., Jongsma, M. L. A., Kessels, R. P. C., & Arns, M. (2017) · Brain Topography · doi:10.1007/s10548-016-0542-y · Cited by 36
I Can See Your Brain: Investigating Home-Use Electroencephalography System Security
Xiao, Y., Jia, Y., Cheng, X., Yu, J., Liang, Z., & Tian, Z. (2019) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2910115 · Cited by 37
Allouch, S., Kabbara, A., Duprez, J., Khalil, M. A., Modolo, J., & Hassan, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120006 · Cited by 39
The diagnostic utility of 3D electroencephalography source imaging in pediatric epilepsy surgery
Russo, A., Jayakar, P., Lallas, M., Miller, I., Hyslop, A. E., Korman, B., Dunoyer, C., Resnick, T., & DUCHOWNY, M. S. (2015) · Epilepsia · doi:10.1111/epi.13228 · Cited by 35
Deep learning multimodal fNIRS and EEG signals for bimanual grip force decoding
Ortega, P., & Faisal, A. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1ab3 · Cited by 35
Hatlestad‐Hall, C., Bruña, R., Liljeström, M., Renvall, H., Heuser, K., Taubøll, E., Maestú, F., & Haraldsen, I. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.03.002 · Cited by 41
Magnetoencephalographic spikes not detected by conventional electroencephalography
Rodin�, E., Funke, M. E., Berg, P., & Matsuo, F. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.002 · Cited by 35
Tatum, W. O., Mani, J., Jin, K., Halford, J. J., Gloss, D. S., Fahoum, F., Maillard, L. G., Mothersill, I. W., & Beniczky, S. (2021) · Epilepsia · doi:10.1111/epi.16977 · Cited by 36
Intrinsic Coupling Modes in Source-Reconstructed Electroencephalography
Mehrkanoon, S., Breakspear, M. J., Britz, J., & Boonstra, T. W. (2014) · Brain Connectivity · doi:10.1089/brain.2014.0280 · Cited by 35
Elshoff, L., Muthuraman, M., Anwar, A. R., Deuschl, G., Stephani, U., Raethjen, J., & Siniatchkin, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0078422 · Cited by 33
de Peralta, R. G., Andino, S. L. G., & Gómez, C. M. (2004) · Revista de Neurología · doi:10.33588/rn.3908.2004038 · Cited by 33
Dynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
Feng, R., Hu, J., Pan, L., Wu, J., Lang, L., Jiang, S., Gu, X., Guo, J. X., & Zhou, L. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.03.009 · Cited by 32
Park, H.-M., Nakasato, N., Iwasaki, M., Shamoto, H., Tominaga, T., & Yoshimoto, T. (2004) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.203.165 · Cited by 32
High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)
Gavaret, M., Maillard, L. G., & Jung, J. (2015) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2014.11.011 · Cited by 32
High density EEG—What do we have to lose?
Chu, C. J. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.07.003 · Cited by 32
Validating EEG source imaging using intracranial electrical stimulation
Unnwongse, K., Rampp, S., Wehner, T., Kowoll, A., Parpaley, Y., von Lehe, M., Lanfer, B., Rusiniak, M., Wolters, C. H., & Wellmer, J. (2022) · Brain Communications · doi:10.1093/braincomms/fcad023 · Cited by 31
Tokariev, A., Vanhatalo, S., & Palva, J. M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.291 · Cited by 31
Effect of Brain-to-Skull Conductivity Ratio on EEG Source Localization Accuracy
Wang, G., & Ren, D. (2013) · BioMed Research International · doi:10.1155/2013/459346 · Cited by 30
Kuhnke, N. G., Klus, C., Dümpelmann, M., Schulze‐Bonhage, A., & Jacobs, J. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.10.016 · Cited by 30
EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
Cox, B. C., Danoun, O. A., Lundstrom, B. N., Lagerlund, T. D., Wong‐Kisiel, L. C., & Brinkmann, B. H. (2021) · Brain Communications · doi:10.1093/braincomms/fcab278 · Cited by 30
A novel hydrogel electrolyte extender for rapid application of EEG sensors and extended recordings
Kleffner, K., Luu, P., Naleway, J. J., & Tucker, D. M. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.11.021 · Cited by 30
Contributions of EEG-fMRI to Assessing the Epileptogenicity of Focal Cortical Dysplasia
Pittau, F., Ferri, L., Fahoum, F., Dubeau, F., & Gotman, J. (2017) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2017.00008 · Cited by 30
Forward and inverse electroencephalographic modeling in health and in acute traumatic brain injury
Andrei Irimia, A., Goh, S. Y. M., Torgerson, C. M., Chambers, M. C., Kikinis, R., & Horn, J. D. V. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.04.336 · Cited by 29
MEG and EEG Sensitivity in a Case of Medial Occipital Epilepsy
Gavaret, M., Badier, J., Bartoloméi, F., Bénar, C., & Chauvel, P. (2013) · Brain Topography · doi:10.1007/s10548-013-0317-7 · Cited by 29
Vespa, S., Baroumand, A. G., Santos, S. F., Vrielynck, P., de Tourtchaninoff, M., Feys, O., Strobbe, G., Raftopoulos, C., van Mierlo, P., & Tahry, R. E. (2020) · Seizure · doi:10.1016/j.seizure.2020.03.001 · Cited by 28
Vorderwülbecke, B. J., Carboni, M., Tourbier, S., Brunet, D., Seeber, M., Spinelli, L., Seeck, M., & Vulliémoz, S. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.09.018 · Cited by 28
Self-citationYe, S., Yang, L., Lu, Y., Kucewicz, M. T., Brinkmann, B. H., Nelson, C., Sohrabpour, A., Worrell, G. A., & He, B. (2020) · Neurology · doi:10.1212/wnl.0000000000011109 · Cited by 28
Andrei Irimia, A., Goh, S.-Y. M., Torgerson, C. M., Stein, N. R., Chambers, M. C., Vespa, P. M., & Horn, J. D. V. (2013) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2013.08.003 · Cited by 28
Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes
Makeyev, O., Ding, Q., & Besio, W. G. (2015) · Measurement · doi:10.1016/j.measurement.2015.11.017 · Cited by 28
EEG-based emotion recognition utilizing wavelet coefficients
Momennezhad, A. (2018) · Multimedia Tools and Applications · doi:10.1007/s11042-018-5906-8 · Cited by 27
Zhang, J., Villringer, A., & Nikulin, V. V. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.846017 · Cited by 27
Dense Array EEG Source Estimation in Neocortical Epilepsy
Yamazaki, M., Tucker, D. M., Terrill, M., Fujimoto, A., & Yamamoto, T. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00042 · Cited by 27
Swatzyna, R. J., Boutros, N. N., Genovese, A., MacInerney, E. K., Roark, A. J., & Kozlowski, G. P. (2018) · European Child & Adolescent Psychiatry · doi:10.1007/s00787-018-1225-x · Cited by 27
Soler, A. F., Moctezuma, L. A., Giraldo, E., & Molinas, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-15252-0 · Cited by 26
Heers, M., Böttcher, S., Kalina, A., Katletz, S., Altenmüller, D., Baroumand, A. G., Strobbe, G., van Mierlo, P., von Oertzen, T. J., Marusič, P., et al. (2022) · Epilepsia · doi:10.1111/epi.17246 · Cited by 26
82 dB SNDR 20-channel incremental ADC with optimal decimation filter and digital correction
Yu, W., Aslan, M., & Temes, G. C. (2010) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2010.5617596 · Cited by 26
Consistency of local activation parameters at sensor- and source-level in neural signals
Rodríguez-González, V., Gómez, C., Shigihara, Y., Hoshi, H., Revilla-Vallejo, M., Hornero, R., & Poza, J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb582 · Cited by 25
Multichannel recording of median nerve somatosensory evoked potentials
van de Wassenberg, W. J. G., van der Hoeven, J., Leenders, K. L., & Maurits, N. M. (2007) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2007.08.002 · Cited by 24
Martinez-Vargas, J. D., Strobbe, G., Vonck, K. E. J., van Mierlo, P., & Castellanos-Dominguez, G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00156 · Cited by 24
Imaging the electric neuronal generators of EEG/MEG
Pascual-Marqui, R. D., Sekihara, K., Brandeis, D., & Michel, C. M. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596889.004 · Cited by 24
Self-citationMapping of the central sulcus using non-invasive ultra-high-density brain recordings
Schreiner, L., Jordan, M., Sieghartsleitner, S., Kapeller, C., Pretl, H., Kamada, K., Asman, P., Ince, N. F., Miller, K. J., & Guger, C. (2024) · Scientific Reports · doi:10.1038/s41598-024-57167-y · Cited by 25
Efficient high resolution sLORETA in brain source localization
Sadat-Nejad, Y., & Beheshti, S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcc48 · Cited by 22
Automated interictal source localisation based on high-density EEG
Vorderwülbecke, B. J., Baroumand, A. G., Spinelli, L., Seeck, M., van Mierlo, P., & Vulliémoz, S. (2021) · Seizure · doi:10.1016/j.seizure.2021.09.020 · Cited by 23
Self-citationEvent-Related Potentials Elicited by the Explicit and Implicit Processing of Familiarity in Faces
Saavedra, C., Iglesias, J., & Olivares, E. (2010) · Clinical EEG and Neuroscience · doi:10.1177/155005941004100107 · Cited by 25
Yang, P., Fan, C., Wang, M., & Li, L. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00247 · Cited by 24
Rikir, E., Maillard, L. G., Abdallah, C., Gavaret, M., Bartoloméi, F., Vignal, J., Colnat‐Coulbois, S., & Koessler, L. (2020) · Brain Topography · doi:10.1007/s10548-020-00768-3 · Cited by 23
Study on the spatial resolution of EEG - effect of electrode density and measurement noise
Ryynanen, O., Hyttinen, J., & Malmivuo, J. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404226 · Cited by 23
Kannan, M. A., Aziz, N. A. A., Rani, N. S. A., Abdullah, M. W., Rashid, M. H. M., Shab, M. S., Ismail, N. I., Ghani, M. A. A., Reza, F., & Mustapha, M. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e12308 · Cited by 47
Jung, K., Cho, J.-W., Joo, E. Y., Kim, S. H., Choi, K. M., Chin, J., Park, K. W., & Hong, S. B. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.013 · Cited by 21
Makeyev, O., & Besio, W. G. (2016) · Sensors · doi:10.3390/s16060858 · Cited by 21
Makeyev, O., Boudria, Y., Zhu, Z., Lennon, T., & Besio, W. G. (2013) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2013.6736778 · Cited by 21
Effortful control and resting state networks: A longitudinal EEG study
Knyazev, G. G., Savostyanov, A. N., Bocharov, A. V., Slobodskaya, H. R., Bairova, N. B., Tamozhnikov, S. S., & Stepanova, V. V. (2017) · Neuroscience · doi:10.1016/j.neuroscience.2017.01.031 · Cited by 25
Electric source imaging for presurgical epilepsy evaluation: current status and future prospects
Mégevand, P., & Seeck, M. (2020) · Expert Review of Medical Devices · doi:10.1080/17434440.2020.1748008 · Cited by 21
Self-citationMeckes-Ferber, S., Roten, A., Kilpatrick, C. J., & O'Brien, T. J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.023 · Cited by 21
The absence of resting-state high-gamma cross-frequency coupling in patients with tinnitus
Ahn, M.-H., Hong, S. K., & Min, B. (2017) · Hearing Research · doi:10.1016/j.heares.2017.10.008 · Cited by 20
Recent Developments in Spatio-Temporal EEG Source Reconstruction Techniques
Kaur, C., Singh, P. B., Bisht, A., Joshi, G., & Agrawal, S. (2021) · Wireless Personal Communications · doi:10.1007/s11277-021-08960-9 · Cited by 20
Michel, C. M. (2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00012-6 · Cited by 20
Self-citationLocalization of Extratemporal Seizure with Noninvasive Dense-Array EEG
Holmes, M., Brown, M. H., Tucker, D. M., Saneto, R. P., Miller, K. J., Wig, G. S., & Ojemann, J. G. (2008) · Pediatric Neurosurgery · doi:10.1159/000180302 · Cited by 19
On noninvasive source imaging of the human K-complex
Wennberg, R. A., & Cheyne, D. O. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.10.022 · Cited by 18
Integrating Dense Array EEG in the Presurgical Evaluation of Temporal Lobe Epilepsy
Yamazaki, M., Terrill, M., Fujimoto, A., Yamamoto, T., & Tucker, D. M. (2012) · ISRN Neurology · doi:10.5402/2012/924081 · Cited by 18
Jäger, V., Dümpelmann, M., LeVan, P., Ramantani, G., Mader, I., Schulze‐Bonhage, A., & Jacobs, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140537 · Cited by 18
Mean-Field Modeling of Brain-Scale Dynamics for the Evaluation of EEG Source-Space Networks
Allouch, S., Yochum, M., Kabbara, A., Duprez, J., Khalil, M. A., Wendling, F., Hassan, M., & Modolo, J. (2021) · Brain Topography · doi:10.1007/s10548-021-00859-9 · Cited by 18
Electrical low‐frequency stimulation induces central neuroplastic changes of pain processing in man
Jung, K., Lelic, D., Rottmann, S., Drewes, A. M., Petrini, L., & Ellrich, J. (2011) · European Journal of Pain · doi:10.1016/j.ejpain.2011.08.006 · Cited by 18
Park, C. J., Seo, J. H., Kim, D., Abibullaev, B., Kwon, H., Lee, Y., Kim, M., An, K., Kim, K., Kim, J. S., et al. (2015) · Journal of Clinical Neurology · doi:10.3988/jcn.2015.11.4.319 · Cited by 18
Navarrete, M., Pyrzowski, J., Corlier, J., Valderrama, M., & Quyen, M. L. V. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.02.003 · Cited by 19
Spatial-temporal-spectral EEG patterns of BOLD functional network connectivity dynamics
Lamoš, M., Mareček, R., Slavicek, T., Mikl, M., Rektor, I., & Jan, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab66b · Cited by 17
MEG for Greater Sensitivity and More Precise Localization in Epilepsy
Burgess, R. C. (2020) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2020.02.004 · Cited by 17
Beamforming applied to surface EEG improves ripple visibility
van Klink, N. E. C., Mol, A., Ferrier, C. H., Hillebrand, A., Huiskamp, G. J. M., & Zijlmans, M. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.10.026 · Cited by 17
Schneider, C., Marquis, R., Jöhr, J., da Silva, M. L., Ryvlin, P., Serino, A., Marzia De Lucia, E., & Diserens, K. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118431 · Cited by 16
Thio, B. J., Aberra, A. S., Dessert, G. E., & Grill, W. M. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.11.002 · Cited by 16
Ismail, L., Karwowski, W., Hancock, P., Taiar, R., & Fernandez-Sumano, R. (2023) · Journal of Integrative Neuroscience · doi:10.31083/j.jin2203062 · Cited by 16
Successful reproduction of a large EEG study across software packages
Kabbara, A., Forde, N., Maumet, C., & Hassan, M. (2023) · Neuroimage Reports · doi:10.1016/j.ynirp.2023.100169 · Cited by 16
Jamous, R., Ghorbani, F., Mückschel, M., Münchau, A. M., Frings, C., & Beste, C. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120891 · Cited by 16
Analysis of generalized interictal discharges using quantitative EEG
Braga, A. M. D. S., Fujisao, E. K., & Betting, L. E. (2014) · Epilepsy Research · doi:10.1016/j.eplepsyres.2014.09.004 · Cited by 16
Magnetoencephalography for localizing and characterizing the epileptic focus
Burgess, R. C. (2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00013-8 · Cited by 16
Formica, C., Gjonaj, E., Bonanno, L., Quercia, A., Cartella, E., Romeo, L., Quartarone, A., Marino, S., & Salvo, S. D. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.03.026 · Cited by 15
EEG–fMRI validation studies in comparison with icEEG: A review
Zhang, J., Liu, W., Chen, H., Xia, H., Zhou, Z. X., Wang, L., Mei, S., Liu, Q., & Li, Y. (2012) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.01.021 · Cited by 15
Metadata
- Authors
- Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M.
- Affiliations
- University of Geneva (CH)
- University Hospital of Geneva (CH)
- Corresponding author
- Lantz, G
- ORCID
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 114
- Issue
- 1
- Pages
- 63-69
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2153208799
- Cited by
- 413
- References
- 30
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 17 · 2023: 25 · 2022: 24 · 2021: 20 · 2020: 27 · 2019: 30 · 2018: 21 · 2017: 27 · 2016: 21 · 2015: 25 · 2014: 26 · 2013: 15 · 2012: 17
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- high-density EEG, electrode number, interictal epileptiform activity, preoperative assessment, distributed source model, inverse solution, epileptogenic lesions, positioning accuracy, multichannel EEG
- MeSH terms
- Adolescent, Adult, Brain, Brain Mapping, Child, Electrodes, Electroencephalography, Epilepsy, Female, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review