The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Epileptic source localization with high density EEG: how many electrodes are needed?
Abstract
Objective Electroencephalography (EEG) source reconstruction is becoming recognized as a useful technique to non-invasively localize the epileptic focus. Whereas, large array magnetoencephalography (MEG) systems are available since quite some time, application difficulties have previously prevented multichannel EEG recordings. Recently, however, EEG systems which allow for quick (10-20min) application of, and recording from, up to 125 electrodes have become available. The purpose of the current investigation was to systematically compare the accuracy of epileptic source localization with high electrode density to that obtained with sparser electrode setups.Methods Interictal epileptiform activity was recorded with 123 electrodes in 14 epileptic patients undergoing presurgical evaluation. Each single epileptiform potential was down sampled to 63 and 31 electrodes, and a distributed source model (EPIFOCUS) was used to reconstruct the sources with the 3 different electrode configurations. The localization accuracy with the 3 electrode setups was then assessed, by determining the distance from the inverse solution, maximum of each single spike to the epileptogenic lesion.Results In 9/14 patients, the distance from the EEG source to the lesion was significantly smaller with 63 than with 31 electrodes, and increasing the number of electrodes to 123 increased this number of patients from 9 to 11. Simulations confirmed the relation between the number of electrodes and localization accuracy.Conclusions The results illustrate the necessity of multichannel EEG recordings for high source location accuracy in epileptic patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Third, the analysis of EEG oscillations did not explore the relationships with brain structure as well as source analysis (Lantz et al. 2003).”
From Changes in Mental Health and EEG Biomarkers of Undergraduates Under Different Patterns of Mindfulness (2024) · cites this paper as Lantz et al. 2003
In the citing paper
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [18]
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of vibration and acoustics · doi:10.1115/1.3269865 · Cited by 6,401
Random data: Analysis and measurement procedures
Braun, S. (1987) · Mechanical Systems and Signal Processing · doi:10.1016/0888-3270(87)90088-4 · Cited by 2,371
Presurgical evaluation of epilepsy.
Rosenow, F., & Lüders, H. (2001) · Brain : a journal of neurology · doi:10.1093/brain/124.9.1683 · Cited by 1,684
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Menéndez, R. G. D. P., Andino, S. L. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 347
Self-citationLocation of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
A new interpretation of the generators of BAEP waves I-V: results of a spatio-temporal dipole model.
Scherg, M., & von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0168-5597(85)90006-1 · Cited by 308
Cited by
Sorted by citations
Items 301–400 of 414
Rolandic spikes – The challenge to differentiate between benign and malignant pediatric epilepsies
Jacobs, J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.041 · Cited by 3
Makeyev, O., Joe, C., Lee, C., & Besio, W. G. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037760 · Cited by 3
New horizons in clinical electric source imaging
Mégevand, P., Hamid, L., Dümpelmann, M., & Heers, M. (2019) · Zeitschrift für Epileptologie · doi:10.1007/s10309-019-0258-6 · Cited by 4
Central-positive complexes in ECT-induced seizures: Evidence for thalamocortical mechanismsPreprint
Huels, E. R., Hickman, L. B., Ching, S., Lenze, E. J., Farber, N. B., Avidan, M. S., Hogan, R. E., & Palanca, B. J. A. (2020) · medRxiv · doi:10.1101/2020.04.28.20072520 · Cited by 3
Xie, Z., Zhang, S., Deng, J., Chen, S., Li, H., Meng, F., & Fang, T. (2024) · Folia Neuropathologica · doi:10.5114/fn.2024.136413 · Cited by 2
Quantifying task-locked information transmission between cortical areas with TMS-EEG
Ding, Z., Ma, W., Feng, L., Zhang, M., & Li, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121323 · Cited by 2
Santos, C., Borges, D. F., & Soares, J. I. (2025) · Epilepsy Research · doi:10.1016/j.eplepsyres.2025.107666 · Cited by 2
Santalucia, R., Carosio, C., Gennari, A. G., Baroumand, A. G., Vrielynck, P., Fierain, A., Guilmot, A., Joris, V., Santos, S. F., Germany, E., et al. (2025) · Neurotherapeutics · doi:10.1016/j.neurot.2025.e00821 · Cited by 2
Stier, C., Loose, M., Loew, C., Segovia‐Oropeza, M., Baek, S., Lerche, H., & Focke, N. K. (2026) · Brain Communications · doi:10.1093/braincomms/fcag022 · Cited by 2
Computing Sources of Epileptic Discharges Using the Novel BMA Approach
Bravo, E. C., Martínez‐Montes, E., Farach-Fumero, M., & Curbelo, C. M. (2012) · Clinical EEG and Neuroscience · doi:10.1177/1550059412451706 · Cited by 2
Momennezhad, A. (2020) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2019-0327 · Cited by 2
Impact of skull-to-brain conductivity ratio for high resolution EEG source localization
Demoulin, G., Pruvost‐Robieux, E., Marchi, A., Ramdani, C., Badier, J., Bartoloméi, F., & Gavaret, M. (2021) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ac177f · Cited by 2
Ranjan, S., & Kumar, L. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3550619 · Cited by 2
Effect of EEG Electrode Numbers on Source Estimation in Motor Imagery
Yazıcı, M., Ulutaş, M., & Okuyan, M. (2025) · Brain Sciences · doi:10.3390/brainsci15070685 · Cited by 2
Quellenanalyse epileptischer Aktivität
Bast, T. (2011) · Clinical Epileptology · doi:10.1007/s10309-011-0226-2 · Cited by 2
Toward improving the laplacian estimation with novel multipolar concentric ring electrodes
Makeyev, O., Ding, Q., Kay, S., & Besio, W. G. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609793 · Cited by 2
Localisation of Focal Epileptic Activity in Children Using High Density EEG Source Imaging
Lantz, G., Grouiller, F., Spinelli, L., & Vulliémoz, S. (2011) · Cited by 2
Self-citationFeasibility of blind source separation methods for the denoising of dense-array EEG
Taheri, N., Kachenoura, A., Ansari-Asl, K., Karfoul, A., Senhadji, L., Albera, L., & Merlet, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319461 · Cited by 2
Ochoa, J. G., Rini, J. F., Diaz, J., & Botwell, J. (2019) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000557 · Cited by 2
Electromagnetic Source Imaging, High-Density EEG and MEG
Beniczky, S., & Sharma, P. (2019) · Springer eBooks · doi:10.1007/978-3-030-04573-9_20 · Cited by 2
Friedrich, E. V. C., Zillekens, I. C., Biel, A. L., O’Leary, D., Singer, J., Seegenschmiedt, E. V., Sauseng, P., & Schilbach, L. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15903 · Cited by 2
Kim, S. J., Nam, H., Lee, S., & Koo, Y. S. (2023) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2023.107740 · Cited by 2
Privacy for Personal NeuroinformaticsPreprint
Stopczynski, A., Greenwood, D., Hansen, L. K., & Pentland, A. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1403.2745 · Cited by 2
Bruña, R., Cuesta, P., Ramírez‐Toraño, F., Suárez‐Méndez, I., & Pereda, E. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.01.19.524740 · Cited by 2
Effect of analytical variability in estimating EEG-based functional connectivityPreprint
Allouch, S., Kabbara, A., Duprez, J., Paban, V., Khalil, M. A., Modolo, J., & Hassan, M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.17.553675 · Cited by 2
Dipole Source Modeling in Epilepsy
Ebersole, J. S. (2009) · Blue books of neurology · doi:10.1016/b978-1-4160-6171-7.00005-4 · Cited by 1
Mao, X., Zhang, Z., Yang, Y., Wang, Y., Chen, Y., & Wang, W. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1520415 · Cited by 1
Predicting fixations and gaze location from EEG
Moreno-Alcayde, Y., Traver, V. J., & Leiva, L. A. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03362-6 · Cited by 1
Denoyer, Y., Duprez, J., Houvenaghel, J., Wendling, F., & Benquet, P. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade6a9 · Cited by 1
Neuroimaging and the Epilepsy Journey
Brinkmann, B. H. (2026) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2025.12.001 · Cited by 1
Olikkal, P., Sundharram, S., Kaviri, S. M., Sharma, S., & Vinjamuri, R. K. (2026) · Springer eBooks · doi:10.1007/978-3-032-06713-5_16 · Cited by 1
Ranjan, S., Badal, R., Yadav, P., & Kumar, L. (2026) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2026.111505 · Cited by 1
Hedlin, H., Boatman, D. F., & Caffo, B. S. (2010) · Collection of Biostatistics Research Archive · Cited by 1
High-density EEG and source analysis: Principles, recent progress and applications in children
Wallois, F., & Bourel‐Ponchel, E. (2015) · Journal of Pediatric Epilepsy · doi:10.3233/pep-13041 · Cited by 1
Mark, D. (2011) · InTech eBooks · doi:10.5772/17244 · Cited by 1
The study of fear-induced power modulations for Cognitive Man-Machine Communication
Irtiza, N., & Farooq, H. (2015) · IEEE International Conference on Cognitive Informatics & Cognitive Computing (ICCI*CC) · doi:10.1109/icci-cc.2015.7259409 · Cited by 1
Dynamic imaging of ictal rhythmic activity using dense-array EEG
Yang, L., Wilke, C. T., Brinkmann, B. H., Worrell, G. A., & He, B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6092039 · Cited by 1
Aarabi, A., Grebe, R., Berquin, P. C., Bourel‐Ponchel, E., Jalin, C., Fohlen, M., Bulteau, C., Delalande, O., Gondry, C., Heberle, C., et al. (2011) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2011.11.001 · Cited by 1
Instrumentation and Signal Processing for Low-frequency Bounded-EIT Studies of the Human Head
Poolman, P., Turovets, S. I., Frank, R. M., & Russell, G. S. (2008) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2008.4547108 · Cited by 1
Makeyev, O., & Besio, W. G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591131 · Cited by 1
Makeyev, O., & Besio, W. G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591132 · Cited by 1
EEG Instrumentation and Basics
Ray, A. K., & Issa, N. P. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108754200.012 · Cited by 1
Lee, S., Kim, H., Kim, J. H., So, M., Kim, J. B., & Kim, D. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1373837 · Cited by 1
High-density event-related potentials: Current theories and practice
Roche, R. A. P., Scanlon, P., & Commins, S. (2006) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 1
Interiktale Quellenlokalisation und Vorteile des High-density-EEG
Gschwind, M., & Seeck, M. (2018) · Clinical Epileptology · doi:10.1007/s10309-018-0196-8 · Cited by 1
Self-citationImproved Back-Projection Cortical Potential Imaging by Multi-resolution Optimization Technique
Haor, D., Joffe, R., Shavit, R., Peremen, Z., Stern, Y., & Geva, A. (2018) · Brain Topography · doi:10.1007/s10548-018-0668-1
EFFECTS OF LOSS AVERSION ON THE EVALUATION OF DECISION OUTCOMES
Kokmotou, A. (2019) · University of Liverpool · doi:10.17638/03046759 · Cited by 1
Methods Used to Estimate EEG Source-Space Networks: A Comparative Simulation-Based Study
Allouch, S., Duprez, J., Khalil, M. A., Hassan, M., Modolo, J., & Kabbara, A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871047 · Cited by 1
Jiang, H. (2022) · Springer eBooks · doi:10.1007/978-3-031-10004-8_4 · Cited by 1
EEG/MEG-Quellenrekonstruktion bei nichtläsioneller Epilepsie
Heide, E., Rampp, S., van de Velden, D., Seeck, M., & Focke, N. K. (2023) · Clinical Epileptology · doi:10.1007/s10309-023-00579-z · Cited by 1
Self-citationStudying connectivity in the neonatal EEG
Tokariev, A. (2015) · Työväentutkimus Vuosikirja · Cited by 1
Topographic Mapping, Frequency Analysis, and Other Digital Techniques in Electroencephalography
Nuwer, M. R. (2005) · Elsevier eBooks · doi:10.1016/b978-0-443-06647-4.50013-6 · Cited by 1
Soler, A. F., Moctezuma, L. A., Giraldo, E., & Molinas, M. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.11.24.469917 · Cited by 1
Allouch, S., Kabbara, A., Duprez, J., Khalil, M. A., Modolo, J., & Hassan, M. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.01.494301 · Cited by 1
Multiple Dipole Source Position and Orientation Estimation using non-invasive EEG SignalsPreprint
Namazifard, S., & Subbarao, K. (2022) · doi:10.36227/techrxiv.21049585 · Cited by 1
Stier, C., Loose, M., Loew, C., Oropeza, M., Baek, S., Lerche, H., & Focke, N. K. (2024) · medRxiv · doi:10.1101/2024.11.25.24317908 · Cited by 1
Wagh, N., Duque-Lopez, A., Joseph, B., Berry, B. M., Jehi, L. E., Crepeau, D., Barnard, L. R., Gogineni, V., Brinkmann, B. H., Jones, D. T., et al. (2025) · medRxiv · doi:10.1101/2025.01.03.25319963 · Cited by 1
Procesamiento de señales e imágenes biomédicas para el estudio de la actividad cerebral
Beltrachini, L. (2012) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/1459
Sturzbecher, M. J. (2011) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.59.2011.tde-08072011-174951
Electroencephalography Electrode Configuration and Source Imaging1
Sohrabpour, A., Lu, Y., Kankirawatana, P., & He, B. (2014) · Journal of Medical Devices · doi:10.1115/1.4027019
A Study on Gel-free Probe for Detecting EEG
Yun, D.-J., Eum, N.-S., & Jeong, M.-Y. (2012) · Journal of Sensor Science and Technology · doi:10.5369/jsst.2012.21.2.156
Long-term depression of nociception and pain in man
Jung, K. (2011)
Epilepsy and Cognition in Childhood
Datta, A., Oser, N., Bechtel, N., Weber, C., Scheffler, K., & Klarhöfer, M. (2011)
Fst-Filter: A flexible spatio-temporal filter for biomedical multichannel data denoising
Nuanprasert, S., Adachi, Y., & Suzuki, T. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318965
A Spatially Focused Method for High Density Electrode-Based Functional Brain Mapping Applications
Chang, C.-W., Hsin, Y.-L., & Liu, W. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2537146
Feature Reduction Using Genetic Algorithm for Cognitive Man-Machine Communication
Irtiza, N., & Farooq, H. (2015) · International Journal of Software Science and Computational Intelligence · doi:10.4018/ijssci.2015100101
Electric source imaging in MRI-negative refractory focal epilepsy
Michel, C. M., & Seeck, M. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139525312.008
Self-citationNeuroimaging Analysis I: Electroencephalography
Marco‐Pallarés, J., Càmara, E., Münte, T. F., & Rodríguez‐Fornells, A. (2009) · SAGE Publications Ltd eBooks · doi:10.4135/9780857020994.n28
Anesthesia for Diagnostic and Therapeutic Radiologic Procedures
Amin, A., & Cutter, T. W. (2018) · doi:10.1093/med/9780190495756.003.0015
Sohrabpour, A., Lu, Y., Worrell, G. A., & He, B. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590652
Localized Electroencephalography Sensor and Detection of Evoked Potentials
de Araujo, T. D. O., Nunes, N., Quintão, C., & Gamboa, H. F. S. (2012) · doi:10.5220/0003891300410046
Ishibashi, H., Ogawa, H., Tamura, Y., Hiroshima, S., & Kamada, K. (2016) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.25.112
Noninvasive Functional Neuroimaging of Electrophysiological Brain Activities in Epilepsy Patients
Lu, Y. (2014) · University of Minnesota Digital Conservancy (University of Minnesota)
Application of Dictionary Learning in Alleviating Computational Burden of EEG Source LocalizationPreprint
Safavi, S. M., Lopour, B. A., & Chou, P. H. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1707.03536
Bildgebung: elektrische EEG-Quellenanalyse
Carboni, M., Toscano, G., & Seeck, M. (2018) · Klinische Neurophysiologie · doi:10.1055/s-0043-125302
Self-citationShafiq, H. (2017) · e-scholar@UOIT (University of Ontario Institute of Technology)
Combining Electrical and Magnetic Fields for Source Analysis: A(n) Attractive or Repelling Thought
Shih, J. J. (2019) · Epiliepsy currents/Epilepsy currents · doi:10.1177/1535759719868692
Monitoring Consciousness and Spatiotemporal Dynamics During Complex Focal Seizures
Khouaja, I., Youkana, I., & Saafi, M. A. (2020) · International Conference on Advanced Technologies for Signal and Image Processing · doi:10.1109/atsip49331.2020.9231891
Inomata, T., & Shimada, S. (2020) · Psychology · doi:10.4236/psych.2020.1110100
Neurophenomenology of Out-of-Body experiences induced by hypnotic suggestionsPreprint
Facco, E., Casiglia, E., Khafaji, B. E. A., Finatti, F., Duma, G. M., Mento, G., Pederzoli, L., & Tressoldi, P. E. (2018) · doi:10.31234/osf.io/6a4hc
High-Density-Elektroenzephalografie
Seeck, M., & Gschwind, M. (2020) · Springer eBooks · doi:10.1007/978-3-662-59198-7_32
Self-citationde la Ossa, L., Juan, J. V., Ortiz, M., Iáñez, E., & Azorín, J. M. (2021) · Servizo de Publicacións da UDC eBooks · doi:10.17979/spudc.9788497498043.140
COALIA: a ground-truth for the evaluation of the EEG source connectivity
Allouch, S., Hassan, M., Yochum, M., Duprez, J., Khalil, M. A., Wendling, F., Modolo, J., & Kabbara, A. (2021) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme53305.2021.9604833
Kannan, M. A., Aziz, N. A. A., Rani, N. S. A., Abdullah, M. W., Rashid, M. H. M., Shab, M. S., Ismail, N. I., Ghani, M. A. A., Reza, F., & Mustapha, M. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4064552
Seeck, M., & Schomer, D. L. (2017) · doi:10.1093/med/9780190228484.003.0029
Self-citationBurgess, R. C. (2014) · Encyclopedia of the Neurological Sciences · doi:10.1016/b978-0-12-385157-4.00546-7
Statistical learning and inference in neural signal processing
Özdenizci, O. (2020) · doi:10.17760/d20382835
Papadelis, C. L., Ricci, L., Matarrese, M. A. G., Peters, J. M., Tamilia, E., Madsen, J. R., & Pearl, P. L. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.06.001
Presurgical focus localization in epilepsy
Mouthaan, B. E. (2022) · Utrecht University Repository (Utrecht University) · doi:10.33540/964
Advances in Electroencephalography and Brain Connectome
Poon, T. L. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.104301
Practical Recommendations for Conducting an EEG Study in a Neurophysiological Laboratory
Гуляев, С. А. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.108879
Smart instead of high-density EEG
Kokkinos, V., & Schuele, S. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.09.003
Luo, Y., Liu, D., Liu, B., & Zhang, J. (2023) · doi:10.31234/osf.io/tzg9s
Cortical tracking of speech is reduced in adults who stutter when listening for speakingPreprint
Gastaldon, S., Busan, P., Molinaro, N., & Lizarazu, M. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.02.23.581767
Neurophenomenology of Out-of-Body experiences induced by hypnotic suggestions
Tressoldi, P. E. (2017) · Figshare · doi:10.6084/m9.figshare.5350135
González, V. R. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/68932
Electroencephalographic Asymmetries in Human Cognition
Assecondi, S., Pagano, S., & Mazza, V. (2024) · Neuromethods · doi:10.1007/978-1-0716-4240-5_15
García, A. M., Koshkin, R., & Paiva, T. O. (2025) · Research methods in applied linguistics · doi:10.1075/rmal.10.12gar
Electroencephalography (EEG) Combined with Neuroimaging and Neurostimulation
Vaudano, A. E., Rampp, S., & Lemieux, L. (2025) · Springer eBooks · doi:10.1007/978-3-031-86878-8_19
Metadata
- Authors
- Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M.
- Affiliations
- University of Geneva (CH)
- University Hospital of Geneva (CH)
- Corresponding author
- Lantz, G
- ORCID
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 114
- Issue
- 1
- Pages
- 63-69
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2153208799
- Cited by
- 413
- References
- 30
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 17 · 2023: 25 · 2022: 24 · 2021: 20 · 2020: 27 · 2019: 30 · 2018: 21 · 2017: 27 · 2016: 21 · 2015: 25 · 2014: 26 · 2013: 15 · 2012: 17
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- high-density EEG, electrode number, interictal epileptiform activity, preoperative assessment, distributed source model, inverse solution, epileptogenic lesions, positioning accuracy, multichannel EEG
- MeSH terms
- Adolescent, Adult, Brain, Brain Mapping, Child, Electrodes, Electroencephalography, Epilepsy, Female, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review