The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Epileptic source localization with high density EEG: how many electrodes are needed?
Abstract
Objective Electroencephalography (EEG) source reconstruction is becoming recognized as a useful technique to non-invasively localize the epileptic focus. Whereas, large array magnetoencephalography (MEG) systems are available since quite some time, application difficulties have previously prevented multichannel EEG recordings. Recently, however, EEG systems which allow for quick (10-20min) application of, and recording from, up to 125 electrodes have become available. The purpose of the current investigation was to systematically compare the accuracy of epileptic source localization with high electrode density to that obtained with sparser electrode setups.Methods Interictal epileptiform activity was recorded with 123 electrodes in 14 epileptic patients undergoing presurgical evaluation. Each single epileptiform potential was down sampled to 63 and 31 electrodes, and a distributed source model (EPIFOCUS) was used to reconstruct the sources with the 3 different electrode configurations. The localization accuracy with the 3 electrode setups was then assessed, by determining the distance from the inverse solution, maximum of each single spike to the epileptogenic lesion.Results In 9/14 patients, the distance from the EEG source to the lesion was significantly smaller with 63 than with 31 electrodes, and increasing the number of electrodes to 123 increased this number of patients from 9 to 11. Simulations confirmed the relation between the number of electrodes and localization accuracy.Conclusions The results illustrate the necessity of multichannel EEG recordings for high source location accuracy in epileptic patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Third, the analysis of EEG oscillations did not explore the relationships with brain structure as well as source analysis (Lantz et al. 2003).”
From Changes in Mental Health and EEG Biomarkers of Undergraduates Under Different Patterns of Mindfulness (2024) · cites this paper as Lantz et al. 2003
In the citing paper
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [18]
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of vibration and acoustics · doi:10.1115/1.3269865 · Cited by 6,401
Random data: Analysis and measurement procedures
Braun, S. (1987) · Mechanical Systems and Signal Processing · doi:10.1016/0888-3270(87)90088-4 · Cited by 2,371
Presurgical evaluation of epilepsy.
Rosenow, F., & Lüders, H. (2001) · Brain : a journal of neurology · doi:10.1093/brain/124.9.1683 · Cited by 1,684
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Menéndez, R. G. D. P., Andino, S. L. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 347
Self-citationLocation of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
A new interpretation of the generators of BAEP waves I-V: results of a spatio-temporal dipole model.
Scherg, M., & von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0168-5597(85)90006-1 · Cited by 308
Cited by
Sorted by citations
Items 201–300 of 414
Feasibility Study of EEG Super-Resolution Using Deep Convolutional Networks
Han, S., Kwon, M., Lee, S., & Jun, S. C. (2018) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2018.00184 · Cited by 15
Osumi, M., Sumitani, M., Nishi, Y., Nobusako, S., Dilek, B., & Morioka, S. (2021) · Behavioural Brain Research · doi:10.1016/j.bbr.2021.113379 · Cited by 15
Conductivity Analysis for High-Resolution EEG
Turovets, S. I., Poolman, P., Salman, A. M., Malony, A. D., & Tucker, D. M. (2008) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2008.358 · Cited by 15
Relative Yield of MEG and EEG Spikes in Simultaneous Recordings
Ebersole, J. S., & Wagner, M. (2018) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000512 · Cited by 15
Multiple Dipole Source Position and Orientation Estimation Using Non-Invasive EEG-like Signals
Namazifard, S., & Subbarao, K. (2023) · Sensors · doi:10.3390/s23052855 · Cited by 16
Sadras, N., Sani, O. G., Ahmadipour, P., & Shanechi, M. M. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acec14 · Cited by 16
Erickson, B. A., Rich, R., Shankar, S., Kim, B., Driscoll, N., Mentzelopoulos, G., Fernandez-Nuñez, G., Vitale, F., & Medaglia, J. D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad141e · Cited by 14
Cortical oscillatory dynamics in a social interaction model
Knyazev, G. G., Slobodskoj‐Plusnin, J. Y., Bocharov, A. V., & Pylkova, L. V. (2012) · Behavioural Brain Research · doi:10.1016/j.bbr.2012.12.010 · Cited by 14
Tóth, M., Faludi, B., & Kondákor, I. (2012) · Brain Topography · doi:10.1007/s10548-012-0243-0 · Cited by 14
Russo, A., Lallas, M., Jayakar, P., Miller, I., Hyslop, A. E., Dunoyer, C., Resnick, T., & DUCHOWNY, M. S. (2016) · Epilepsia · doi:10.1111/epi.13454 · Cited by 14
Local and Distant Dysregulation of Synchronization Around Interictal Spikes in BECTS
Bourel‐Ponchel, E., Mahmoudzadeh, M., Berquin, P. C., & Wallois, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00059 · Cited by 14
Väisänen, O. (2008) · Tampere University Institutional Repository (Tampere University) · Cited by 14
Feature Reconstruction Based Channel Selection for Emotion Recognition Using EEG
Msonda, J. R., He, Z., & Lü, C. (2021) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb52430.2021.9672258 · Cited by 13
The elicitation of steady‐state visual evoked potentials during sleep
Norton, J. J. S., Umunna, S., & Bretl, T. W. (2017) · Psychophysiology · doi:10.1111/psyp.12807 · Cited by 12
Dynamic analysis of fMRI activation during epileptic spikes can help identify the seizure origin
Kowalczyk, M. A., Omidvarnia, A., Dhollander, T., & Jackson, G. D. (2020) · Epilepsia · doi:10.1111/epi.16695 · Cited by 13
Akdeniz, G. (2015) · Annals of Indian Academy of Neurology · doi:10.4103/0972-2327.168632 · Cited by 13
Feng, R., Hu, J., Wu, J., Lang, L., Ma, C., Sun, B., Gu, X., & Pan, L. (2018) · Seizure · doi:10.1016/j.seizure.2018.05.009 · Cited by 13
Visual analysis of high density EEG: As good as electrical source imaging?
Toscano, G., Carboni, M., Rubega, M., Spinelli, L., Pittau, F., Bartoli, A., Momjian, S., Manni, R., Terzaghi, M., Vulliémoz, S., et al. (2019) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2019.09.002 · Cited by 13
Self-citationYang, H., Zhang, T., Zhou, J., Carney, P. R., & Jiang, H. (2014) · Epilepsia · doi:10.1111/epi.12880 · Cited by 13
Petrichella, S., Vollere, L., Ferreri, F., Guerra, A., Määttä, S., Könönen, M., Lazzaro, V. D., & Iannello, G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590868 · Cited by 12
Larsson, P. G., Eeg‐Olofsson, O., Michel, C. M., Seeck, M., & Lantz, G. (2010) · Brain Topography · doi:10.1007/s10548-010-0150-1 · Cited by 12
Self-citationBabiloni, F., Babiloni, C., Carducci, F., Febo Cincotti, A., & Rossini, P. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00193-7 · Cited by 12
Vogrin, S. J., & Plummer, C. (2024) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000001023 · Cited by 11
A neurophysiological investigation of anticipation to pain in Parkinson's disease
Martin, S. L., Jones, A. K. P., Brown, C. A., Kobylecki, C., & Silverdale, M. (2019) · European Journal of Neuroscience · doi:10.1111/ejn.14559 · Cited by 11
Central-positive complexes in ECT-induced seizures: Possible evidence for thalamocortical mechanisms
Huels, E. R., Kafashan, M., Hickman, L. B., Ching, S., Lin, N., Lenze, E. J., Farber, N. B., Avidan, M. S., Hogan, R. E., & Palanca, B. J. A. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.11.015 · Cited by 10
The impact of EEG electrode density on the mapping of cortical activity networks in infants
Asayesh, A., Vanhatalo, S., & Tokariev, A. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120932 · Cited by 10
Moffet, E. W., Verhagen, R., Jones, B., Findlay, G., Juan, E., Bugnon, T., Mensen, A., Aparicio, M. K., Maganti, R. K., Struck, A. F., et al. (2020) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2020.549309 · Cited by 11
The Role of Skull Modeling in EEG Source Imaging for Patients with Refractory Temporal Lobe Epilepsy
Montes-Restrepo, V., Carrette, E., Strobbe, G., Gadeyne, S., Vandenberghe, S., Boon, P., Vonck, K. E. J., & van Mierlo, P. (2016) · Brain Topography · doi:10.1007/s10548-016-0482-6 · Cited by 10
Data acquisition and pre-processing standards for electrical neuroimaging
Michel, C. M., & Brandeis, D. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596889.005 · Cited by 10
Self-citationSensor density and head surface coverage in EEG source localization
Song, J., Davey, C., Poulsen, C., Turovets, S. I., Luu, P., & Tucker, D. M. (2014) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867947 · Cited by 10
Mareček, R., Lamoš, M., Labounek, R., Bartoň, M., Slavicek, T., Mikl, M., Rektor, I., & Brázdil, M. (2017) · Neural Computation · doi:10.1162/neco_a_00933 · Cited by 10
Back-Projection Cortical Potential Imaging: Theory and Results
Haor, D., Shavit, R., Shapiro, M., & Geva, A. B. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2679756 · Cited by 10
Added value and limitations of electrical source localization
Rikir, E., Koessler, L., Ramantani, G., & Maillard, L. G. (2017) · Epilepsia · doi:10.1111/epi.13643 · Cited by 10
Electroencephalography in epilepsy surgery planning
Sarco, D. P., Burke, J. F., & Madsen, J. R. (2006) · Child s Nervous System · doi:10.1007/s00381-006-0128-1 · Cited by 9
A Review on Non-Invasive Localisation of Focal Epileptic Activity Using EEG Source Imaging*
Lascano, A. M., Vulliémoz, S., Lantz, G., Spinelli, L., Michel, C. M., & Seeck, M. (2012) · Cited by 9
Self-citationElectroencephalographic Asymmetries in Human Cognition
Mazza, V., & Pagano, S. (2017) · Neuromethods · doi:10.1007/978-1-4939-6725-4_13 · Cited by 9
Papadelis, C. L., Conrad, S. E., Song, Y., Shandley, S., Hansen, D. R., Bosemani, M., Malik, S. I., Keator, C. G., & Perry, M. S. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.826139 · Cited by 9
Claus, S. P., Leijten, F. S. S., Kallansee, P., Klepper, J., Lopes, F. H. D. S., Ronner, H. E., Velis, D. N., Viergever, M. A., & Kalitzin, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.04.007 · Cited by 9
Sponge EEG is equivalent regarding signal quality, but faster than routine EEG
Günther, M., Schuster, L., Boßelmann, C. M., Lerche, H., Ziemann, U., Feil, K., & Marquetand, J. C. (2023) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2023.03.002 · Cited by 8
Evaluation of EEG pre-processing and source localization in ecological research
Gómez-Tapia, C., Božić, B., & Longo, L. (2025) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2025.1479569 · Cited by 8
Santalucia, R., Carapancea, E., Vespa, S., Germany, E., Baroumand, A. G., Vrielynck, P., Fierain, A., Joris, V., Raftopoulos, C., Duprez, T. P. J., et al. (2023) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2023.109229 · Cited by 8
Sato, Y., Tsuji, Y., Yamazaki, M., Fujii, Y., Shirasawa, A., Harada, K., & Mizutani, T. (2022) · Operative Neurosurgery · doi:10.1227/ons.0000000000000245 · Cited by 8
Avigdor, T., Abdallah, C., Afnan, J., Cai, Z., Rammal, S., Grova, C., & Frauscher, B. (2024) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.51959 · Cited by 8
Knyazev, G. G. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.02.011 · Cited by 8
Makeyev, O., Lee, C., & Besio, W. G. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036955 · Cited by 8
Electric Source Imaging in Presurgical Evaluation of Epilepsy: An Inter-Analyser Agreement Study
Mattioli, P., Cleeren, E., Hadady, L., Cossu, A., Cloppenborg, T., Arnaldi, D., & Beniczky, S. (2022) · Diagnostics · doi:10.3390/diagnostics12102303 · Cited by 7
Interictal Electrical Source Imaging
Rampp, S., Müller-Voggel, N., Hamer, H., Doerfler, A., Brandner, S., & Buchfelder, M. (2023) · Journal of clinical neurophysiology · doi:10.1097/wnp.0000000000001012 · Cited by 6
Nuara, A., Mirandola, L., Fabbri‐Destro, M., Giovannini, G., Vecchiato, G., Vaudano, A. E., Tassinari, C. A., Avanzini, P., & Meletti, S. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.06.028 · Cited by 7
Tomyta, K., & Seki, Y. (2020) · Neuroscience Letters · doi:10.1016/j.neulet.2020.135410 · Cited by 8
Improving surgical outcome with electric source imaging and high field magnetic resonance imaging
Saute, R. L., Peixoto-Santos, J. E., Velasco, T. R., & Leite, J. P. (2021) · Seizure · doi:10.1016/j.seizure.2021.02.006 · Cited by 7
Horrillo‐Maysonnial, A., Avigdor, T., Abdallah, C., Daniel Mansilla, D., Thomas, J., von Ellenrieder, N., Royer, J., Bernhardt, B. C., Grova, C., Gotman, J., et al. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.08.009 · Cited by 7
Kim, J. H. K., Du, P., & Cheng, L. K. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/1193 · Cited by 7
1.1 The Sources and Temporal Dynamics of Scalp Electric Fields
Michel, C. M., & Brandeis, D. (2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195372731.003.0001 · Cited by 7
Self-citationTurovets, S. I., Salman, A. M., Malony, A. D., Poolman, P., Davey, C., & Tucker, D. M. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_975 · Cited by 7
Long-Term Seizure Monitoring Using a 256 Contact Dense Array System
Thompson, P., Rae, J., Weber, L., Pearson, C., Goldeshtein, Z., & Holmes, D. M. (2008) · American Journal of Electroneurodiagnostic Technology · doi:10.1080/1086508x.2008.11079667 · Cited by 7
Kim, J., Lim, K. H., Kim, E., Kim, S., Kim, H. J., Lee, Y. H., Kim, S., & Choi, J. (2025) · Ear and Hearing · doi:10.1097/aud.0000000000001623 · Cited by 6
Mehra, C., Beyh, A., Laiou, P., Garcés, P., Jones, E. J. H., Mason, L., Buitelaar, J. K., Johnson, M. H., Murphy, D., Loth, E., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.985 · Cited by 8
Zauli, F. M., Vecchio, M. D., Pigorini, A., Russo, S., Massimini, M., Sartori, I., Cardinale, F., d’Orio, P., & Mikulan, E. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110193 · Cited by 6
Full density fluorescence molecular tomography (FD-FMT) based on a dichroic mirror
Yang, H., Dai, X., & Jiang, H. (2018) · Applied Optics · doi:10.1364/ao.57.007938 · Cited by 6
Poolman, P., Frank, R. M., & Turovets, S. I. (2008) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2008.680 · Cited by 6
Yitembe, B. R., Crevecoeur, G., Keer, R. V., & Dupré, L. R. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2072909 · Cited by 6
Electroencephalographic and morphometric abnormalities in psychopath offenders
Calzada‐Reyes, A., Alvarez‐Amador, A., Galán‐Garcia, L., & Valdés-Sosa, M. J. (2021) · Behavioral Sciences & the Law · doi:10.1002/bsl.2548 · Cited by 6
Heide, E., van de Velden, D., Garnica-Agudelo, D., Hewitt, M., Riedel, C. H., & Focke, N. K. (2023) · Epilepsia Open · doi:10.1002/epi4.12732 · Cited by 6
Influence of the stereo-EEG sensors setup and of the averaging on the dipole localization problem
Cam, S. L., Caune, V., Ranta, R., Maillard, L. G., Koessler, L., & Louis-Dorr, V. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943798 · Cited by 6
Electroencephalography (EEG): Inverse Problems
He, B., Hori, J.-I., & Babiloni, F. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs0655 · Cited by 6
Knowlton, R. C. (2024) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000001033 · Cited by 5
Deep learning-based EEG source imaging is robust under varying electrode configurations
Rong, J., Sun, R., Joseph, B., Worrell, G. A., & He, B. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.04.009 · Cited by 7
Imaging epileptogenic brain using high density EEG source imaging and MRI
He, B., & Sohrabpour, A. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.074 · Cited by 5
Kouti, M., Ansari-Asl, K., & Namjoo, E. (2019) · Network Computation in Neural Systems · doi:10.1080/0954898x.2019.1634290 · Cited by 5
Semi-automated EEG Enhancement Improves Localization of Ictal Onset Zone With EEG-Correlated fMRI
Eyndhoven, S. V., Hunyadi, B., Dupont, P. J., Paesschen, W. V., & Huffel, S. V. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00805 · Cited by 5
Evaluating interhemispheric connectivity during midline object recognition using EEG
Das, A., Mandel, A., Shitara, H., Popa, T., Horovitz, S. G., Hallett, M., & Thirugnanasambandam, N. (2022) · PLoS ONE · doi:10.1371/journal.pone.0270949 · Cited by 18
Language lateralization mapping (reversibly) masked by non-dominant focal epilepsy: a case report
Abarrategui, B., Mariani, V., Rizzi, M., Berta, L., Scarpa, P., Zauli, F. M., Squarza, S. A. C., Banfi, P., d’Orio, P., Cardinale, F., et al. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1254779 · Cited by 5
Mao, X., Zhang, Z., Yang, Y., Chen, Y., Wang, Y., & Wang, W. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1277129 · Cited by 5
Handling anisotropic conductivities in the EEG forward problem with a symmetric formulation
Pillain, A., Rahmouni, L., & Andriulli, F. P. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aafaaf · Cited by 5
Functional Significance of Individual Differences in P3 Network Spatial Configuration
Privitera, A. J., & Tang, A. C. (2022) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000295 · Cited by 5
Privitera, A. J., Sun, R., & Tang, A. C. (2022) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2022.111488 · Cited by 6
Influence of skull inhomogeneities on EEG source localization
Montes-Restrepo, V., Hallez, H., & Staelens, S. G. (2011) · Joint Meeting of International Symposium on Noninvasive Functional Source Imaging of Brain and Heart and International Conference on Functional Biomedical Imaging · doi:10.1109/nfsi.2011.5936823 · Cited by 5
Multi-Resolution Graph Based Volumetric Cortical Basis Functions from Local Anatomic Features
Hyde, D., Peters, J., & Warfield, S. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2904473 · Cited by 2
Explorations EEG et vidéo-EEG des épilepsies partielles pharmaco-résistantes
Bartoloméi, F., Gavaret, M., Badier, J., Marquis, P., & Chauvel, P. (2004) · Revue Neurologique · doi:10.1016/s0035-3787(04)71186-8 · Cited by 5
Yang, H., & Jiang, H. (2013) · Applied Optics · doi:10.1364/ao.52.005036 · Cited by 5
Makeyev, O., Lennon, T., Boudria, Y., Zhu, Z., & Besio, W. G. (2014) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebec.2014.6972865 · Cited by 4
Safavi, S. M., Lopour, B. A., & Chou, P. H. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2793882 · Cited by 4
Quintiliani, M., Bianchi, F., Fuggetta, F., Chieffo, D. P. R., Ramaglia, A., Battaglia, D., & Tamburrini, G. (2021) · Child s Nervous System · doi:10.1007/s00381-021-05069-z · Cited by 4
High density electric source imaging in childhood-onset epilepsy due to focal cortical dysplasia
Wanders, A., Garibotto, V., Spinelli, L., Beniczky, S., Vulliémoz, S., Daniel, R. T., Schaller, K., Bartoli, A., Korff, C. M., & Seeck, M. (2022) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2022.07.002 · Cited by 4
Self-citationGarcía, F. (2017) · ProQuest LLC eBooks · doi:10.7916/d8r21cpf · Cited by 4
Fujisao, E. K., Alves, K. F., Rezende, T. O. P., & Betting, L. E. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.569943 · Cited by 4
Localization with high-density EEG: Complexity of analysis versus accuracy
Acharya, V. J., & Acharya, J. N. (2019) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2019.11.001 · Cited by 4
Luo, M., Gan, Q., Huang, Z., Jiang, Y., Li, K., Wu, M., Yang, D., Shao, H., Chen, Y., Fu, Y., et al. (2024) · Brain Topography · doi:10.1007/s10548-023-01026-y · Cited by 3
“Third, the analysis of EEG oscillations did not explore the relationships with brain structure as well as source analysis (Lantz et al. 2003).”
Neural signatures of engagement in driving: comparing active control and passive observation
Li, Z., Kambara, H., & Koike, Y. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1698625 · Cited by 3
A Review of EEG Artifact Removal Techniques for Brain-Computer Interface
Dhole, P. V., Chaudhary, D. G., Dhangar, V. D., Shejul, S. D., Datwase, S. S., & Gawali, B. W. (2025) · SN Computer Science · doi:10.1007/s42979-025-04592-z · Cited by 3
Koshizawa, R., Oki, K., & Takayose, M. (2024) · Journal of Integrative Neuroscience · doi:10.31083/j.jin2306108 · Cited by 3
Samantaray, S., Goyal, N., Kesavan, M., Venkatasubramanian, G., Bose, A., Shreekantiah, U., Sreeraj, V. S., Das, M., Raj, J. P. C., & Kumar, S. (2025) · Brain Topography · doi:10.1007/s10548-025-01103-4 · Cited by 3
Wagh, N., Duque-Lopez, A., Joseph, B., Berry, B. M., Jehi, L., Crepeau, D., Barnard, L., Gogineni, V., Brinkmann, B., Jones, D. T., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-08871-w · Cited by 2
Source Localization Based on Ictal Electroencephalographic Recordings
Subramaniyam, N., Peltola, J., Tanskanen, J., Wendel-Mitoraj, K. E., Hyttinen, J., & Malmivuo, J. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-34197-7_7 · Cited by 3
Generalized and hybrid fast-ICA implementation using GPU
Kumara, T. N., Gamaarachchi, H., Kulathunga, G., & Ragel, R. (2016) · International Conference on Advances in ICT for Emerging Regions · doi:10.1109/icter.2016.7829893 · Cited by 3
Limotai, C., Mokklaew, J., Sukaem, B., Jirasakuldej, S., Prakkamakul, S., Tepmongkol, S., & Bunyaratavej, K. (2023) · Journal of neurosurgery · doi:10.3171/2023.6.jns222695 · Cited by 3
Effects of EEG Electrode Numbers on Deep Learning-Based Source Imaging
Rong, J., Sun, R., Guo, Y., & He, B. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-43075-6_11 · Cited by 2
Cortical Tracking of Speech Is Reduced in Adults Who Stutter When Listening for Speaking
Gastaldon, S., Busan, P., Molinaro, N., & Lizarazu, M. (2024) · Journal of Speech Language and Hearing Research · doi:10.1044/2024_jslhr-24-00227 · Cited by 4
Topographic Mapping, Frequency Analysis, and Other Quantitative Techniques in Electroencephalography
Nuwer, M. R., & Coutin-Churchman, P. E. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-0308-1.00008-x · Cited by 3
Chapter 51 Intracranial monitoring
Seeck, M., & Spinelli, L. (2004) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70387-3 · Cited by 3
Self-citation
Metadata
- Authors
- Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M.
- Affiliations
- University of Geneva (CH)
- University Hospital of Geneva (CH)
- Corresponding author
- Lantz, G
- ORCID
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 114
- Issue
- 1
- Pages
- 63-69
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2153208799
- Cited by
- 413
- References
- 30
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 17 · 2023: 25 · 2022: 24 · 2021: 20 · 2020: 27 · 2019: 30 · 2018: 21 · 2017: 27 · 2016: 21 · 2015: 25 · 2014: 26 · 2013: 15 · 2012: 17
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- high-density EEG, electrode number, interictal epileptiform activity, preoperative assessment, distributed source model, inverse solution, epileptogenic lesions, positioning accuracy, multichannel EEG
- MeSH terms
- Adolescent, Adult, Brain, Brain Mapping, Child, Electrodes, Electroencephalography, Epilepsy, Female, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review