Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Background The comparative performance of different clinical sampling methods for diagnosis of SARS-CoV-2 infection by RT-PCR among populations with suspected infection remains unclear. This meta-analysis aims to systematically compare the diagnostic performance of different clinical specimen collection methods. Methods In this systematic review and meta-analysis, we systematically searched PubMed, Embase, MEDLINE, Web of Science, medRxiv, bioRxiv, SSRN, and Research Square from Jan 1, 2000, to Nov 16, 2020. We included original clinical studies that examined the performance of nasopharyngeal swabs and any additional respiratory specimens for the diagnosis of SARS-CoV-2 infection among individuals presenting in ambulatory care. Studies without data on paired samples, or those that only examined different samples from confirmed SARS-CoV-2 cases were not useful for examining diagnostic performance of a test and were excluded. Diagnostic performance, including sensitivity, specificity, positive predictive value, and negative predictive value, was examined using random effects models and double arcsine transformation. Findings Of the 5577 studies identified in our search, 23 studies including 7973 participants with 16 762 respiratory samples were included. Respiratory specimens examined in these studies included 7973 nasopharyngeal swabs, 1622 nasal swabs, 6110 saliva samples, 338 throat swabs, and 719 pooled nasal and throat swabs. Using nasopharyngeal swabs as the gold standard, pooled nasal and throat swabs gave the highest sensitivity of 97% (95% CI 93–100), whereas lower sensitivities were achieved by saliva (85%, 75–93) and nasal swabs (86%, 77–93) and a much lower sensitivity by throat swabs (68%, 35–94). A comparably high positive predictive value was obtained by pooled nasal and throat (97%, 90–100) and nasal swabs (96%, 87–100) and a slightly lower positive predictive value by saliva (93%, 88–97). Throat swabs have the lowest positive predictive value of 75% (95% CI 45–96). Comparably high specificities (range 97–99%) and negative predictive value (range 95–99%) were observed among different clinical specimens. Comparison between health-care-worker collection and self-collection for pooled nasal and throat swabs and nasal swabs showed comparable diagnostic performance. No significant heterogeneity was observed in the analysis of pooled nasal and throat swabs and throat swabs, whereas moderate to substantial heterogeneity (I2 ≥30%) was observed in studies on saliva and nasal swabs. Interpretation Our review suggests that, compared with the gold standard of nasopharyngeal swabs, pooled nasal and throat swabs offered the best diagnostic performance of the alternative sampling approaches for diagnosis of SARS-CoV-2 infection in ambulatory care. Saliva and nasal swabs gave comparable and very good diagnostic performance and are clinically acceptable alternative specimen collection methods. Throat swabs gave a much lower sensitivity and positive predictive value and should not be recommended. Self-collection for pooled nasal and throat swabs and nasal swabs was not associated with any significant impairment of diagnostic accuracy. Our results also provide a useful reference framework for the proper interpretation of SARS-CoV-2 testing results using different clinical specimens. Funding Hong Kong Research Grants Council.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Ma, L.-L., Wang, Y.-Y., Yang, Z.-H., Huang, D., Weng, H., & Zeng, X.-T. (2020) · Military Medical Research · doi:10.1186/s40779-020-00238-8 · Cited by 1,648
A comparison of heterogeneity variance estimators in simulated random‐effects meta‐analyses
Langan, D., Higgins, J. P. T., Jackson, D., Bowden, J., Veroniki, A. A., Kontopantelis, E., Viechtbauer, W., & Simmonds, M. (2019) · Research Synthesis Methods · doi:10.1002/jrsm.1316 · Cited by 1,074
Immune response, inflammation, and the clinical spectrum of COVID-19
García, L. F. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01441 · Cited by 739
False-negative results of initial RT-PCR assays for COVID-19: A systematic review
Arevalo-Rodriguez, I., Buitrago-Garcia, D., Simancas-Racines, D., Zambrano-Achig, P., Del Campo, R., Ciapponi, A., Sued, O., Martinez-García, L., Rutjes, A. W., Low, N., et al. (2020) · PLOS ONE · doi:10.1371/journal.pone.0242958 · Cited by 656
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
The Inverse of the Freeman – Tukey Double Arcsine Transformation
Miller, J. J. (1978) · The American Statistician · doi:10.1080/00031305.1978.10479283 · Cited by 535
Systematic review with meta-analysis of the accuracy of diagnostic tests for COVID-19
Böger, B., Fachi, M. M., Vilhena, R. O., Cobre, A. F., Tonin, F. S., & Pontarolo, R. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.07.011 · Cited by 491
Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy
Song, F., Khan, K. S., Dinnes, J., & Sutton, A. J. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.88 · Cited by 484
COVID-19: towards understanding of pathogenesis
Cao, W., & Li, T. (2020) · Cell Research · doi:10.1038/s41422-020-0327-4 · Cited by 344
FALSE-NEGATIVE RESULTS OF INITIAL RT-PCR ASSAYS FOR COVID-19: A SYSTEMATIC REVIEW
Arevalo-Rodriguez, I., Buitrago-Garcia, D., Simancas-Racines, D., Zambrano-Achig, P., Campo, R. D., Ciapponi, A., Sued, O., Martínez-García, L., Rutjes, A., Low, N., et al. (2020) · medRxiv · doi:10.1101/2020.04.16.20066787 · Cited by 310
Lee, R. A., Herigon, J. C., Benedetti, A., Pollock, N. R., & Denkinger, C. M. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.02881-20 · Cited by 297
Butler-Laporte, G., Lawandi, A., Schiller, I., Yao, M., Dendukuri, N., McDonald, E. G., & Lee, T. C. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.8876 · Cited by 294
Wang, X., Tan, L., Wang, X., Liu, W., Lu, Y., Cheng, L., & Sun, Z. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.04.023 · Cited by 252
Swabs Collected by Patients or Health Care Workers for SARS-CoV-2 Testing
Tu, Y.-P., Jennings, R., Hart, B., Cangelosi, G. A., Wood, R. C., Wehber, K., Verma, P., Vojta, D., & Berke, E. M. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2016321 · Cited by 244
Veroniki, A. A., Jackson, D., Bender, R., Kuss, O., Langan, D., Higgins, J. P. T., Knapp, G., & Salanti, G. (2019) · Research Synthesis Methods · doi:10.1002/jrsm.1319 · Cited by 236
Saliva as a Candidate for COVID-19 Diagnostic Testing: A Meta-Analysis
Czumbel, L. M., Kiss, S., Farkas, N., Mandel, I., Hegyi, A., Nagy, Á., Lohinai, Z., Szakács, Z., Hegyi, P., Steward, M. C., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00465 · Cited by 235
Bwire, G. M., Majigo, M. V., Njiro, B. J., & Mawazo, A. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26349 · Cited by 230
Basu, A., Zinger, T., Inglima, K., Woo, K.-M., Atie, O., Yurasits, L., See, B., & Aguero-Rosenfeld, M. E. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.01136-20 · Cited by 224
Detection of SARS-CoV-2 in nasal swabs using MALDI-MS
Nachtigall, F. M., Pereira, A., Trofymchuk, O. S., & Santos, L. S. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0644-7 · Cited by 216
Kojima, N., Turner, F., Slepnev, V, Bacelar, A., Deming, L., Kodeboyina, S., & Klausner, J. D. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1589 · Cited by 196
How to Obtain a Nasopharyngeal Swab Specimen
(2020) · New England Journal of Medicine · doi:10.1056/nejmc2015949 · Cited by 179
Viral dynamics of SARS-CoV-2 in saliva from infected patients
Zhu, J., Guo, J., Xu, Y., & Chen, X. (2020) · Journal of Infection · doi:10.1016/j.jinf.2020.06.059 · Cited by 177
Harrington, A., Cox, B., Snowdon, J., Bakst, J., Ley, E., Grajales, P., Maggiore, J., & Kahn, S. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00798-20 · Cited by 162
Bastos, M. L., Perlman-Arrow, S., Menzies, D., & Campbell, J. R. (2021) · Annals of Internal Medicine · doi:10.7326/m20-6569 · Cited by 162
SARS-CoV-2 detection in different respiratory sites: A systematic review and meta-analysis
Mohammadi, A., Esmaeilzadeh, E., Li, Y., Bosch, R. J., & Li, J. Z. (2020) · EBioMedicine · doi:10.1016/j.ebiom.2020.102903 · Cited by 161
Péré, H., Podglajen, I., Wack, M., Flamarion, E., Mirault, T., Goudot, G., Hauw‐Berlemont, C., Lê, L. M. M., Caudron, É., Carrabin, S., et al. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00721-20 · Cited by 155
Rhoads, D. D., Cherian, S., Roman, K. P., Stempak, L. M., Schmotzer, C. L., & Sadri, N. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00760-20 · Cited by 153
Challenges in use of saliva for detection of SARS CoV-2 RNA in symptomatic outpatients
Landry, M. L., Criscuolo, J., & Peaper, D. R. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104567 · Cited by 151
Additional molecular testing of saliva specimens improves the detection of respiratory viruses
To, K. K., Lu, L., Yip, C. C. Y., Poon, R. W., Fung, A. M. Y., Cheng, A., Lui, D. H., Ho, D. T.-Y., Hung, I. F., Chan, K., et al. (2017) · Emerging Microbes & Infections · doi:10.1038/emi.2017.35 · Cited by 143
Weiss, A., Jellingsø, M., & Sommer, M. O. A. (2020) · EBioMedicine · doi:10.1016/j.ebiom.2020.102916 · Cited by 139
McCormick-Baw, C., Morgan, K., Gaffney, D., Cazares, Y., Jaworski, K., Byrd, A., Molberg, K. H., & Cavuoti, D. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.01109-20 · Cited by 118
McCulloch, D. J., Kim, A. E., Wilcox, N. C., Logue, J. K., Greninger, A. L., Englund, J. A., & Chu, H. Y. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.16382 · Cited by 111
LeBlanc, J. J., Heinstein, C., MacDonald, J., Pettipas, J., Hatchette, T. F., & Patriquin, G. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104442 · Cited by 91
Valentine-Graves, M., Hall, E., Guest, J. L., Adam, E., Valencia, R., Hardee, I., Shinn, K., Sanchez, T., Siegler, A. J., & Sullivan, P. S. (2020) · PLoS ONE · doi:10.1371/journal.pone.0236775 · Cited by 88
Saliva Is a Promising Alternative Specimen for the Detection of SARS-CoV-2 in Children and Adults
Yee, R., Truong, T., Pannaraj, P. S., Eubanks, N., Gai, E., Jumarang, J., Turner, L. S., Peralta, A., Lee, Y., & Bard, J. D. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.02686-20 · Cited by 82
Xu, C. L. H., Raval, M., Schnall, J., Kwong, J. C., & Holmes, N. E. (2020) · The Pediatric Infectious Disease Journal · doi:10.1097/inf.0000000000002814 · Cited by 81
Saliva as a diagnostic specimen for detection of SARS-CoV-2 in suspected patients: a scoping review
Fakheran, O., Dehghannejad, M., & Khademi, A. (2020) · Infectious Diseases of Poverty · doi:10.1186/s40249-020-00728-w · Cited by 72
Senok, A. C., Suwaidi, H. S. A., Atrah, Y., Ayedi, O. A., Zahid, J. A., Han, A., Al Marzooqi, A., Heialy, S. A., Altrabulsi, B., AbdelWareth, L., et al. (2020) · Infection and Drug Resistance · doi:10.2147/idr.s275152 · Cited by 61
Clinical Samples for SARS-CoV-2 Detection: Review of the Early Literature
Martinez, R. M. (2020) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2020.07.001 · Cited by 55
Altawalah, H., Alhuraish, F., Alkandari, W. A., & Ezzikouri, S. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104652 · Cited by 54
Evaluation of saliva as diagnostic materials for influenza virus infection by PCR-based assays
Sueki, A., Matsuda, K., Yamaguchi, A., Uehara, M., Sugano, M., Uehara, T., & Honda, T. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.12.006 · Cited by 52
Pinninti, S. G., Trieu, C., Pati, S. K., Latting, M., Cooper, J., Seleme, M. C., Boppana, S., Arora, N., Britt, W. J., & Boppana, S. B. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa882 · Cited by 51
Nasal Swab as Preferred Clinical Specimen for COVID-19 Testing in Children
Palmas, G., Moriondo, M., Trapani, S., Ricci, S., Calistri, E., Pisano, L., Perferi, G., Galli, L., Venturini, E., Indolfi, G., et al. (2020) · The Pediatric Infectious Disease Journal · doi:10.1097/inf.0000000000002812 · Cited by 42
Ip, D., Schutten, M., Fang, V. J., Fung, R. O. P., Dutkowski, R. T., Chan, K., Leung, G. M., Peiris, M. J. S., & Cowling, B. J. (2011) · The Journal of Infectious Diseases · doi:10.1093/infdis/jir803 · Cited by 40
Self-citationTajima, Y., Suda, Y., & Yano, K. (2020) · Journal of Infection and Chemotherapy · doi:10.1016/j.jiac.2020.06.011 · Cited by 36
Guest, J. L., Sullivan, P. S., Valentine-Graves, M., Valencia, R., Adam, E., Luisi, N., Nakano, M., Guarner, J., del Rı́o, C., Sailey, C., et al. (2020) · JMIR Public Health and Surveillance · doi:10.2196/19731 · Cited by 35
Nasal-Swab Testing Misses Patients with Low SARS-CoV-2 Viral LoadsPreprint
Callahan, C. J., Lee, R. A., Lee, G. R., Zulauf, K. E., Kirby, J. E., & Arnaout, R. (2020) · medRxiv · doi:10.1101/2020.06.12.20128736 · Cited by 32
Sensitivity of Nasopharyngeal, Nasal and Throat Swab for the Detection of SARS-CoV-2Preprint
Berenger, B. M., Fonseca, K., Schneider, A. R., Hu, J., & Zelyas, N. J. (2020) · medRxiv · doi:10.1101/2020.05.05.20084889 · Cited by 26
Mestdagh, P., Gillard, M. R., Dhillon, S. K., Pirnay, J., Poels, J., Hellemans, J., Hutse, V., Vermeiren, C., Boutier, M., Wever, V. D., et al. (2021) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2021.07.017 · Cited by 15
Explaining heterogeneity in meta-analysis: a comparison of methods
Thompson, S. G., & Sharp, S. J. (1999) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19991030)18:20
Cited by
Emerging COVID-19 variants and their impact on SARS-CoV-2 diagnosis, therapeutics and vaccines
Fernandes, Q., Inchakalody, V. P., Merhi, M., Mestiri, S., Taib, N., Moustafa Abo El-Ella, D., Bedhiafi, T., Raza, A., Al-Zaidan, L., Mohsen, M. O., et al. (2022) · Annals of Medicine · doi:10.1080/07853890.2022.2031274 · Cited by 447
SARS-CoV-2 viral load and shedding kinetics
Puhach, O., Meyer, B., & Eckerle, I. (2022) · Nature Reviews Microbiology · doi:10.1038/s41579-022-00822-w · Cited by 424
Metadata
- Authors
- Tsang, N. N. Y., So, H. C., Ng, K. Y., Cowling, B. J., Leung, G. M., & Ip, D. K. M.
- Venue
- The Lancet Infectious Diseases
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 21
- Issue
- 9
- Pages
- 1233-1245
- ISSN
- 1473-3099 (ISSN-L)
- OpenAlex
- W3153427680
- Cited by
- 287
- References
- 53
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.