Cited by 21Bone Tissue Engineering MaterialsCollagen: Extraction and CharacterizationElectrospun Nanofibers in Biomedical Applications

Biomimetic synthesis of collagen/nano-hydroxyapitate scaffold for tissue engineering

Liu, Chao-zong·2008·Journal of Bionic Engineering

Integrity signals

Registry

Crossref · 10.1016/s1672-6529(08)60064-5

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Liu [63] found that higher nano-HA concentration declines porosity to 54%, while deprived nano-HA gives higher porosity of 78%.

    “the report published by Liu [63] validates the above statement where the change in nano-HA moiety alters the porosity of the overall scaffold i.e. as the nano-HA was present in higher concentration, the porosity declines to 54% but higher porosity (78%) was obtained when nano-HA was found deprived.”
  • Nano-HA rich scaffold displays low porosity with high mechanical strength.

    “Nano-HA rich scaffold display low [63] | porosity with high mechanical | strength while nano-HA deplete | region display high porosity with | low mechanical strength.”
  • Nano-HA deplete region displays high porosity with low mechanical strength.

    “Nano-HA rich scaffold display low [63] | porosity with high mechanical | strength while nano-HA deplete | region display high porosity with | low mechanical strength.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liu, C.-Z.
Venue
Journal of Bionic Engineering
Published
2008-03
Volume
5
Issue
S1
Pages
1-8
ISSN
  • 1672-6529 (ISSN-L)
  • 2543-2141
OpenAlex
W2088300109
Cited by
21
References
40
Citations by year
2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2017: 1 · 2015: 1 · 2014: 5 · 2013: 4 · 2012: 1
FWCI
1.11
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Bionic Engineering (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
Keywords
precipitation method, calcium phosphate precipitation, collagen fibrils, porosity, porous network structure, tissue engineering scaffolds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review