Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Efficacy and safety of maintenance and reliever combination budesonide–formoterol inhaler in patients with asthma at risk of severe exacerbations: a randomised controlled trial

Open access
Patel, Mitesh, Pilcher, Janine, Pritchard, Alison, Perrin, Kyle, Travers, Justin, Shaw, Dominick, Holt, Shaun, Harwood, Matire, Black, Peter, Weatherall, Mark, Beasley, Richard·2013·The Lancet Respiratory Medicine

Abstract

BACKGROUND The Single combination budesonide-formoterol inhaler Maintenance And Reliever Therapy (SMART) regimen reduces severe asthma exacerbations in patients, but whether the high doses of corticosteroid and β agonist increase the risk of adverse effects with both short-term and cumulative exposure is not certain. Our aim was to investigate whether the SMART regimen would reduce the risk of overuse of β agonist, reduce the likelihood of patients to seek medical review when such episodes occurred, and if any reduction in severe asthma exacerbations would be at the cost of a higher burden of systemic corticosteroid. METHODS In this 24-week trial undertaken at four primary health-care practices and one hospital in New Zealand, patients (aged 16-65 years) with a recent asthma exacerbation were randomly assigned in a 1:1 ratio to the SMART or standard fixed-dose regimen. Treatment in the SMART group consisted of two actuations of budesonide-formoterol (200 μg and 6 μg, respectively, per actuation) twice daily, delivered through a combination metered dose inhaler (MDI), with one extra actuation as needed for relief of symptoms; treatment in the standard group consisted of two actuations of budesonide-formoterol (200 μg and 6 μg, respectively, per actuation) twice daily through a combination MDI with one to two actuations of salbutamol (100 μg per actuation) by MDI as needed for relief of symptoms. MDIs were monitored electronically to measure actual use of medication. The allocation sequence for randomisation was computer generated, with a block size of eight per site. Participants, investigators, and the statistician were not masked to group assignment. The primary outcome was the proportion of participants with at least one high-use episode of β agonist (more than eight actuations per day of budesonide-formoterol in addition to the four maintenance doses in the SMART group or more than 16 actuations per day of salbutamol in the standard group). Analysis was by intention to treat. This trial is registered with the Australian New Zealand Clinical Trials Registry, number ACTRN12610000515099. FINDINGS 303 patients were randomly assigned to the SMART (n=151) or standard group (n=152). No significant difference was noted between the SMART and standard groups in the proportion of participants with at least one high-use episode of β agonist (84 [56%] vs 68 [45%], respectively, relative risk 1·24 [95% CI 0·99-1·56]; p=0·058). There were fewer days of high use in the SMART group (mean 5·1 days [SD 14·3] vs 8·9 days [20·9], relative rate 0·58 [0·39-0·88]; p=0·01). Of the patients who had at least one high-use episode, those in the SMART group had fewer days of high use without medical review (8·5 days [17·8] vs 18·3 days [24·8], 0·49 [0·31-0·75]; p=0·001). The SMART regimen resulted in higher inhaled corticosteroid exposure (943·5 μg budesonide per day [1502·5] vs 684·3 μg budesonide per day [390·5], respectively; ratio of means 1·22 [1·06-1·41]; p=0·006), but reduced oral corticosteroid exposure (77·5 mg prednisone [240·5] vs 126·6 mg prednisone [382·1], respectively; p=0·011), with no significant difference in composite systemic corticosteroid exposure (793·7 mg prednisone equivalent per year [893·1] vs 772·1 mg prednisone equivalent per year [1062·7], respectively; 1·03 [0·86-1·22]; p=0·76). Participants in the SMART group had fewer severe asthma exacerbations (35 [weighted mean rate per year 0·53] vs 66 [0·97]; relative rate 0·54 [0·36-0·82]; p=0·004). INTERPRETATION The SMART regimen has a favourable risk-to-benefit profile and can be recommended for use in adults at risk of severe asthma exacerbations. FUNDING Health Research Council of New Zealand.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2213-2600(13)70007-9

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 207

Metadata

Authors
Patel, M., Pilcher, J., Pritchard, A., Perrin, K., Travers, J., Shaw, D., Holt, S., Harwood, M., Black, P., Weatherall, M., & Beasley, R.
Venue
The Lancet Respiratory Medicine
Publisher
Elsevier BV
Published
2013-03
Volume
1
Issue
1
Pages
32-42
ISSN
2213-2600 (ISSN-L)
OpenAlex
W2026491091
Cited by
207
References
2
FWCI
10.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and safety of maintenance and reliever combination budesonide–formoterol inhaler in patients with asthma at risk of severe exacerbations: a randomised controlled trial. https://app.cochat.ai/papers/10.1016/s2213-2600(13)70007-9
The paper
Patel, M., Pilcher, J., Pritchard, A., Perrin, K., Travers, J., Shaw, D., Holt, S., Harwood, M., Black, P., Weatherall, M., & Beasley, R. (2013). Efficacy and safety of maintenance and reliever combination budesonide–formoterol inhaler in patients with asthma at risk of severe exacerbations: a randomised controlled trial. The Lancet Respiratory Medicine. https://doi.org/10.1016/s2213-2600(13)70007-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.