CoChat

Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trial

Open access
Bosi, Emanuele, Choudhary, Pratik, de Valk, Harold W, Lablanche, Sandrine, Castañeda, Javier, de Portu, Simona, Da Silva, Julien, Ré, Roseline, Vorrink-de Groot, Linda, Shin, John, Kaufman, Francine R, Cohen, Ohad, Laurenzi, Andrea, Caretto, Amelia, Slatterly, David, Henderson-Wilson, Marcia, Weisnagel, S. John, Dubé, Marie-Christine, Julien, Valérie-Ève, Trevisan, Roberto, Lepore, Giuseppe, Bellante, Rosalia, Hramiak, Irene, Spaic, Tamara, Driscoll, Marsha, Borot, Sophie, Clergeot, Annie, Khiat, Lamia, Hammond, Peter, Ray, Sutapa, Dinning, Laura, Tonolo, Giancarlo, Manconi, Alberto, Ledda, Maura Serena, de Ranitz, Wendela, Silvius, Bianca, Wojtusciszyn, Anne, Farret, Anne, Vriesendorp, Titia, Immeker-de Jong, Folkje, van der Linden, Joke, Brink, Huguette S., Alkemade, Marije, Schaepelynck-Belicar, Pauline, Galie, Sébastien, Tréglia, Clémence, Benhamou, Pierre-Yves, Haddouche, Myriam, Hoogma, Roel, Leelarathna, Lalantha, Shaju, Angel, James, Linda · 2019 · The Lancet Diabetes & Endocrinology
Cited by 125

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND Hypoglycaemia unawareness and severe hypoglycaemia can increase fear of hypoglycaemia and the risk of subsequent hypoglycaemic events. We aimed to assess the safety and efficacy of insulin pump therapy with integrated continuous glucose monitoring (CGM) and a suspend-before-low feature (Medtronic MiniMed 640G with SmartGuard) in hypoglycaemia-prone adults with type 1 diabetes. METHODS SMILE was an open-label randomised controlled trial done in people aged 24-75 years with type 1 diabetes for 10 years or longer, HbA1c values of 5·8-10·0% (40-86 mmol/mol), and at high risk of hypoglycaemia (recent severe hypoglycaemia or hypoglycaemia unawareness defined by a Clarke or Gold score ≥4). Participants were enrolled from 16 centres (eg, clinics, hospitals, or university medical centres) in Canada, France, Italy, the Netherlands, and the UK. After baseline run-in phase (2 weeks), participants were randomly assigned to the MiniMed 640G pump (continuous subcutaneous insulin infusion) with self-monitoring of blood glucose (control group) or to the MiniMed 640G system with the suspend-before-low feature enabled (intervention group), for 6 months. The study statistician analysing the data was masked to group assignment until final database lock; because of the nature of the intervention, participants and treating clinicians could not be masked to group assignment. The primary outcome was the mean number of sensor hypoglycaemic events, defined as 55 mg/dL (3·1 mmol/L) or lower, and was analysed on an intention-to-treat basis in all randomly assigned participants. This trial is registered with ClinicalTrials.gov, number NCT02733991, and is completed. FINDINGS Between Dec 7, 2016, and March 27, 2018, 153 participants with a mean age 48·2 [12·4] years were randomly assigned: 77 to the control group (mean age 47·4 [12·5] years) and 76 to the intervention group (mean age 49·0 [12·2] years). After 6 months, the intervention group had significantly fewer hypoglycaemic events per participant per week (1·1 [SD 1·2] vs 4·1 [3·4] mean events, model-based treatment effect -2·9 [95% CI -3·5 to -2·3]; p<0·0001) and fewer severe hypoglycaemic events (instances requiring third-party assistance with carbohydrate or glucagon administration, or other resuscitative actions) overall (three vs 18; p=0·0036). The most common adverse events were hypoglycaemia (observed in ten [13%] of 77 participants in the control group vs four [5%] of 76 in the intervention group) and hyperglycaemia (observed in seven [9%] of 77 vs seven [9%] of 76). No serious adverse device effects or episodes of diabetic ketoacidosis were reported. INTERPRETATION Insulin pump therapy with integrated CGM and a suspend-before-low feature reduced the frequency of sensor hypoglycaemic and severe hypoglycaemic events in hypoglycaemia-prone adults compared with use of continuous subcutaneous insulin infusion without real-time CGM. These results suggest that this technology could be beneficial in this high-risk population. FUNDING Medtronic International Trading Sàrl and Medtronic Canada.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2213-8587(19)30150-0

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 125

Metadata

Authors
Bosi, E., Choudhary, P., de Valk, H. W., Lablanche, S., Castañeda, J., de Portu, S., Da Silva, J., Ré, R., Vorrink-de Groot, L., Shin, J., Kaufman, F. R., Cohen, O., Laurenzi, A., Caretto, A., Slatterly, D., Henderson-Wilson, M., Weisnagel, S. J., Dubé, M.-C., Julien, V.-È., Trevisan, R., Lepore, G., Bellante, R., Hramiak, I., Spaic, T., Driscoll, M., Borot, S., Clergeot, A., Khiat, L., Hammond, P., Ray, S., Dinning, L., Tonolo, G., Manconi, A., Ledda, M. S., de Ranitz, W., Silvius, B., Wojtusciszyn, A., Farret, A., Vriesendorp, T., Immeker-de Jong, F., van der Linden, J., Brink, H. S., Alkemade, M., Schaepelynck-Belicar, P., Galie, S., Tréglia, C., Benhamou, P.-Y., Haddouche, M., Hoogma, R., Leelarathna, L., Shaju, A., & James, L.
Venue
The Lancet Diabetes & Endocrinology
Publisher
Elsevier BV
Published
2019-06
Volume
7
Issue
6
Pages
462-472
ISSN
2213-8587 (ISSN-L)
OpenAlex
W2943761611
Cited by
125
References
20
FWCI
13.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trial. https://app.cochat.ai/papers/10.1016/s2213-8587(19)30150-0
The paper
Bosi, E., Choudhary, P., de Valk, H. W., Lablanche, S., Castañeda, J., de Portu, S., Da Silva, J., Ré, R., Vorrink-de Groot, L., Shin, J., Kaufman, F. R., Cohen, O., Laurenzi, A., Caretto, A., Slatterly, D., Henderson-Wilson, M., Weisnagel, S. J., Dubé, M.-C., Julien, V.-È., . . . James, L. (2019). Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trial. The Lancet Diabetes & Endocrinology. https://doi.org/10.1016/s2213-8587(19)30150-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.