The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Safety and effectiveness of SGM-101, a fluorescent antibody targeting carcinoembryonic antigen, for intraoperative detection of colorectal cancer: a dose-escalation pilot study
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
Tumorigenesis and the angiogenic switch
Bergers, G., & Benjamin, L. E. (2003) · Nature reviews. Cancer · doi:10.1038/nrc1093 · Cited by 3,559
Cited by
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Latest developments in molecular tracers for fluorescence image-guided cancer surgery
Hernot, S., van Manen, L., Debie, P., Mieog, J. S. D., & Vahrmeijer, A. L. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30317-1 · Cited by 471
Self-citationFundamentals and developments in fluorescence-guided cancer surgery
Mieog, J. S. D., Achterberg, F. B., Zlitni, A., Hutteman, M., Burggraaf, J., Swijnenburg, R.-J., Gioux, S., & Vahrmeijer, A. L. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00548-3 · Cited by 389
Self-citationReal-time fluorescence imaging in intraoperative decision making for cancer surgery
Lauwerends, L. J., van Driel, P. B. A. A., Baatenburg de Jong, R. J., Hardillo, J. A. U., Koljenovic, S., Puppels, G., Mezzanotte, L., Löwik, C. W. G. M., Rosenthal, E. L., Vahrmeijer, A. L., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(20)30600-8 · Cited by 276
Self-citationApplication of Fluorescent Dyes in Visceral Surgery: State of the Art and Future Perspectives
Nowak, K., Karampinis, I., & Gerken, A. L. H. (2020) · Visceral Medicine · doi:10.1159/000506910 · Cited by 32
Metadata
- Authors
- Boogerd, L. S. F., Hoogstins, C. E. S., Schaap, D. P., Kusters, M., Handgraaf, H. J. M., van der Valk, M. J. M., Hilling, D. E., Holman, F. A., Peeters, K. C. M. J., Mieog, J. S. D., van de Velde, C. J. H., Farina-Sarasqueta, A., van Lijnschoten, I., Framery, B., Pèlegrin, A., Gutowski, M., Nienhuijs, S. W., de Hingh, I. H. J. T., Nieuwenhuijzen, G. A. P., Rutten, H. J. T., Cailler, F., Burggraaf, J., & Vahrmeijer, A. L.
- Venue
- The Lancet Gastroenterology & Hepatology
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 3
- Issue
- 3
- Pages
- 181-191
- ISSN
- 2468-1156 (ISSN-L)
- 2468-1253
- OpenAlex
- W2782700569
- Cited by
- 198
- References
- 2
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and effectiveness of SGM-101, a fluorescent antibody targeting carcinoembryonic antigen, for intraoperative detection of colorectal cancer: a dose-escalation pilot study. https://app.cochat.ai/papers/10.1016/s2468-1253(17)30395-3
- The paper
- Boogerd, L. S. F., Hoogstins, C. E. S., Schaap, D. P., Kusters, M., Handgraaf, H. J. M., van der Valk, M. J. M., Hilling, D. E., Holman, F. A., Peeters, K. C. M. J., Mieog, J. S. D., van de Velde, C. J. H., Farina-Sarasqueta, A., van Lijnschoten, I., Framery, B., Pèlegrin, A., Gutowski, M., Nienhuijs, S. W., de Hingh, I. H. J. T., Nieuwenhuijzen, G. A. P., . . . Vahrmeijer, A. L. (2018). Safety and effectiveness of SGM-101, a fluorescent antibody targeting carcinoembryonic antigen, for intraoperative detection of colorectal cancer: a dose-escalation pilot study. The Lancet Gastroenterology & Hepatology. https://doi.org/10.1016/s2468-1253(17)30395-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.