Changes in cancer detection and false-positive recall in mammography using artificial intelligence: a retrospective, multireader study
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Mammography is the current standard for breast cancer screening. This study aimed to develop an artificial intelligence (AI) algorithm for diagnosis of breast cancer in mammography, and explore whether it could benefit radiologists by improving accuracy of diagnosis. METHODS: In this retrospective study, an AI algorithm was developed and validated with 170 230 mammography examinations collected from five institutions in South Korea, the USA, and the UK, including 36 468 cancer positive confirmed by biopsy, 59 544 benign confirmed by biopsy (8827 mammograms) or follow-up imaging (50 717 mammograms), and 74 218 normal. For the multicentre, observer-blinded, reader study, 320 mammograms (160 cancer positive, 64 benign, 96 normal) were independently obtained from two institutions. 14 radiologists participated as readers and assessed each mammogram in terms of likelihood of malignancy (LOM), location of malignancy, and necessity to recall the patient, first without and then with assistance of the AI algorithm. The performance of AI and radiologists was evaluated in terms of LOM-based area under the receiver operating characteristic curve (AUROC) and recall-based sensitivity and specificity. FINDINGS: The AI standalone performance was AUROC 0·959 (95% CI 0·952-0·966) overall, and 0·970 (0·963-0·978) in the South Korea dataset, 0·953 (0·938-0·968) in the USA dataset, and 0·938 (0·918-0·958) in the UK dataset. In the reader study, the performance level of AI was 0·940 (0·915-0·965), significantly higher than that of the radiologists without AI assistance (0·810, 95% CI 0·770-0·850; p<0·0001). With the assistance of AI, radiologists' performance was improved to 0·881 (0·850-0·911; p<0·0001). AI was more sensitive to detect cancers with mass (53 [90%] vs 46 [78%] of 59 cancers detected; p=0·044) or distortion or asymmetry (18 [90%] vs ten [50%] of 20 cancers detected; p=0·023) than radiologists. AI was better in detection of T1 cancers (73 [91%] vs 59 [74%] of 80; p=0·0039) or node-negative cancers (104 [87%] vs 88 [74%] of 119; p=0·0025) than radiologists. INTERPRETATION: The AI algorithm developed with large-scale mammography data showed better diagnostic performance in breast cancer detection compared with radiologists. The significant improvement in radiologists' performance when aided by AI supports application of AI to mammograms as a diagnostic support tool. FUNDING: Lunit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Learning Deconvolution Network for Semantic Segmentation
Noh, H., Hong, S., & Han, B. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.178 · Cited by 4,422
Self-citationEhteshami Bejnordi, B., Veta, M., Johannes van Diest, P., van Ginneken, B., Karssemeijer, N., Litjens, G., van der Laak, J. A. W. M., and the CAMELYON16 Consortium, Hermsen, M., Manson, Q. F., et al. (2017) · JAMA · doi:10.1001/jama.2017.14585 · Cited by 3,293
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 751
Tabar, L., Yen, M.-F., Vitak, B., Chen, H.-H. T., Smith, R. A., & Duffy, S. W. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13143-1 · Cited by 742
Cited by
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
“For instance, AI assistance has some-times been shown to improve clinical experts’ sensitivity while lowering their specificity 8,86 , and some studies, both prospective and retrospective, have found that combined AI–human performance could not surpass the performance of AI alone 90,91 .”
BackgroundRevolutionizing healthcare: the role of artificial intelligence in clinical practice
Alowais, S. A., Alghamdi, S. S., Alsuhebany, N., Alqahtani, T., Alshaya, A. I., Almohareb, S. N., Aldairem, A., Alrashed, M., Bin Saleh, K., Badreldin, H. A., et al. (2023) · BMC Medical Education · doi:10.1186/s12909-023-04698-z · Cited by 3,146
“Also, AI was better at detecting early breast cancer (91%) than radiologists 74% [12].”
BackgroundSwanson, K., Wu, E., Zhang, A., Alizadeh, A. A., & Zou, J. (2023) · Cell · doi:10.1016/j.cell.2023.01.035 · Cited by 597
“designed a reader study in which radiologists evaluated mammograms either with or without the aid of anMLmodel trained onmammograms from five institutions in three countries.(34) Radiologists from multiple institutions had superior performance when working in conjunction with ML rather than alone.”
BackgroundLotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Dembrower, K., Crippa, A., Colón, E., Eklund, M., & Strand, F. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00153-x · Cited by 358
Sechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Khan, S. M., Liu, X., Nath, S., Korot, E., Faes, L., Wagner, S. K., Keane, P. A., Sebire, N. J., Burton, M. J., & Denniston, A. K. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30240-5 · Cited by 334
The Role of Artificial Intelligence in Early Cancer Diagnosis
Hunter, B., Hindocha, S., & Lee, R. W. (2022) · Cancers · doi:10.3390/cancers14061524 · Cited by 332
Oren, O., Gersh, B. J., & Bhatt, D. L. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30160-6 · Cited by 316
Dembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
Toward robust mammography-based models for breast cancer risk
Yala, A., Mikhael, P. G., Strand, F., Lin, G., Smith, K., Wan, Y.-L., Lamb, L., Hughes, K., Lehman, C., & Barzilay, R. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.aba4373 · Cited by 287
Benchmarking saliency methods for chest X-ray interpretation
Saporta, A., Gui, X., Agrawal, A., Pareek, A., Truong, S. Q. H., Nguyen, C. D. T., Ngo, V.-D., Seekins, J., Blankenberg, F. G., Ng, A. Y., et al. (2022) · Nature Machine Intelligence · doi:10.1038/s42256-022-00536-x · Cited by 270
Artificial Intelligence in Breast Cancer Diagnosis and Personalized Medicine
Ahn, J. S., Shin, S., Yang, S.-A., Park, E. K., Kim, K. H., Cho, S. I., Ock, C.-Y., & Kim, S. (2023) · Journal of Breast Cancer · doi:10.4048/jbc.2023.26.e45 · Cited by 221
“In a reader study by Kim et al. [56], it has been shown that the diagnostic accuracy of the readers increases with AI, and the incremental range is dependent on the experience level of the readers.”
BackgroundInfluentialSelf-citationCombining the strengths of radiologists and AI for breast cancer screening: a retrospective analysis
Leibig, C., Brehmer, M., Bunk, S., Byng, D., Pinker, K., & Umutlu, L. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00070-x · Cited by 202
“…of lesions on the basis of digital mammography data have shown that such systems have comparable diagnostic performance to radiologists and are promising as decision support systems, 2–8 but the current evidence is insufficient to judge accuracy within breast-cancer screening programmes.”
Fountzilas, E., Pearce, T., Baysal, M. A., Chakraborty, A., & Tsimberidou, A. M. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01471-y · Cited by 190
A generalist medical language model for disease diagnosis assistance
Liu, X., Liu, H., Yang, G., Jiang, Z., Cui, S., Zhang, Z., Wang, H., Tao, L., Sun, Y., Song, Z., et al. (2025) · Nature Medicine · doi:10.1038/s41591-024-03416-6 · Cited by 183
“This phenomenon has also been observed in previous studies (for example, mammography cancer detection 32 and chest X-ray interpretation 33 ).”
Raya-Povedano, J. L., Romero-Martín, S., Elías-Cabot, E., Gubern-Mérida, A., Rodríguez-Ruiz, A., & Álvarez-Benito, M. (2021) · Radiology · doi:10.1148/radiol.2021203555 · Cited by 177
Combining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.2139/ssrn.4505053 · Cited by 161
“Research on the effectiveness of human-AI collaboration is evolving, with notable studies in radiology including Rajpurkar et al. (2020); Kim et al. (2020); Park et al. (2019); Seah et al. (2021); Fogliato et al. (2022).”
BackgroundCombining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.3386/w31422 · Cited by 161
Pacilè, S., Lopez, J., Chone, P., Bertinotti, T., Grouin, J. M., & Fillard, P. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190208 · Cited by 161
“However, apart from the use-case tested (AI tested as a second reader by Kim et al, and AI tested as stand-alone system by McKinney et al), the major difference that emerged with the present study was that mammograms collected in the very same centers used for algorithm training were used during validation, while inde…”
ResultArtificial intelligence in healthcare: A bibliometric analysis
Jimma, B. L. (2023) · Telematics and Informatics Reports · doi:10.1016/j.teler.2023.100041 · Cited by 133
Aquino, Y. S. J., Rogers, W. A., Braunack-Mayer, A., Frazer, H., Win, K. T., Houssami, N., Degeling, C., Semsarian, C., & Carter, S. M. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2022.104903 · Cited by 131
Dvijotham, K., Winkens, J., Barsbey, M., Ghaisas, S., Stanforth, R., Pawlowski, N., Strachan, P., Ahmed, Z., Azizi, S., Bachrach, Y., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02437-x · Cited by 120
Chen, Y., Stavropoulou, C., Narasinkan, R., Baker, A., & Scarbrough, H. (2021) · BMC Health Services Research · doi:10.1186/s12913-021-06861-y · Cited by 87
“For example, an AI algorithm for diagnosis in mammography in breast cancer has been used successfully in identifying imaging abnormalities in an accurate and timely manner [5], while another AI algorithm in thoracic cancer was shown to equal or even ex-”
MethodYeo, M., Tahayori, B., Kok, H. K., Maingard, J., Kutaiba, N., Russell, J., Thijs, V., Jhamb, A., Chandra, R. V., Brooks, M., et al. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-017099 · Cited by 65
Differences between human and machine perception in medical diagnosis
Makino, T., Jastrzębski, S., Oleszkiewicz, W., Chacko, C., Ehrenpreis, R., Samreen, N., Chhor, C., Kim, E., Lee, J., Pysarenko, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-10526-z · Cited by 30
Self-citationAuloge, P., Garnon, J., Robinson, J. M., Dbouk, S., Sibilia, J., Braun, M., Vanpee, D., Koch, G., Cazzato, R. L., & Gangi, A. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00942-y · Cited by 17
The value of simulation testing for the evaluation of ambient digital scribes: a case report
Biro, J. M., Handley, J. L., Mickler, J., Reddy, S., Kottamasu, V., Ratwani, R. M., & Cobb, N. K. (2025) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaf052 · Cited by 10
Metadata
- Authors
- Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 2
- Issue
- 3
- Pages
- e138-e148
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W3004691496
- Cited by
- 525
- References
- 31
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.