Automatic multilabel electrocardiogram diagnosis of heart rhythm or conduction abnormalities with deep learning: a cohort study
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Market-applicable concurrent electrocardiogram (ECG) diagnosis for multiple heart abnormalities that covers a wide range of arrhythmias, with better-than-human accuracy, has not yet been developed. We therefore aimed to engineer a deep learning approach for the automated multilabel diagnosis of heart rhythm or conduction abnormalities by real-time ECG analysis. METHODS: We used a dataset of ECGs (standard 10 s, 12-channel format) from adult patients (aged ≥18 years), with 21 distinct rhythm classes, including most types of heart rhythm or conduction abnormalities, for the diagnosis of arrhythmias at multilabel level. The ECGs were collected from three campuses of Tongji Hospital (Huazhong University of Science and Technology, Wuhan, China) and annotated by cardiologists. We used these datasets to develop a convolutional neural network approach to generate diagnoses of arrythmias. We collected a test dataset of ECGs from a new group of patients not included in the training dataset. The test dataset was annotated by consensus of a committee of board-certified, actively practicing cardiologists. To evaluate the performance of the model we assessed the F1 score and the area under the curve (AUC) of the receiver operating characteristic (ROC) curve, as well as quantifying sensitivity and specificity. To validate our results, findings for the test dataset were compared with diagnoses made by 53 ECG physicians working in cardiology departments who had a wide range of experience in ECG interpretation (range 0 to >12 years). An external public validation dataset of 962 ECGs from other hospitals was used to study generalisability of the diagnostic model. FINDINGS: Our training and validation dataset comprised 180 112 ECGs from 70 692 patients, collected between Jan 1, 2012, and Apr 30, 2019. The test dataset comprised 828 ECGs corresponding to 828 new patients, recorded between Sept 11, 2012, and Aug 30, 2019. At the multilabel level, our deep learning approach to diagnosing heart abnormalities resulted in an exact match in 658 (80%) of 828 ECGs, exceeding the mean performance of physicians (552 [67%] for physicians with 0-6 years of experience; 571 [69%] for physicians with 7-12 years of experience; 621 [75%] for physicians with more than 12 years of experience). Our model had an overall mean F1 score of 0·887 compared with 0·789 for physicians with 0-6 years of experience, 0·815 for physicians with 7-12 years of experience, and 0·831 for physicians with more than 12 years of experience. The model had a mean AUC ROC score of 0·983 (95% CI 0·980-0·986), sensitivity of 0·867 (0·849-0·885) and specificity of 0·995 (0·994-0·996). Promising F1 scores were also obtained from the external public database using our proposed model without any model modifications (mean F1 scores of 0·845 in multilabel and 0·852 in single-label ECGs). INTERPRETATION: Our model is more accurate than physicians working in cardiology departments at distinguishing a range of distinct arrhythmias in single-label and multilabel ECGs, laying a promising foundation for computational decision-support systems in clinical applications. FUNDING: National Natural Science Foundation of China and Hubei Science and Technology Project.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
A Review on Multi-Label Learning Algorithms
Zhang, M.-L., & Zhou, Z.-H. (2014) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2013.39 · Cited by 3,321
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram
Surawicz, B., Childers, R., Deal, B. J., & Gettes, L. S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.013 · Cited by 2,032
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Arrhythmia detection using deep convolutional neural network with long duration ECG signals
Yıldırım, Ö., Pławiak, P., Tan, R.-S., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.009 · Cited by 851
Clifford, G., Liu, C., Moody, B., Lehman, L.-W., Silva, I., Li, Q., Johnson, A., & Mark, R. (2017) · Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2017.065-469 · Cited by 838
Yildirim, Ö. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.03.016 · Cited by 833
Surawicz, B., Childers, R., Deal, B. J., & Gettes, L. S. (2009) · Circulation · doi:10.1161/circulationaha.108.191095 · Cited by 773
Liu, F., Liu, C., Zhao, L., Zhang, X., Wu, X., Xu, X., Liu, Y., Ma, C., Wei, S., He, Z., et al. (2018) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2018.2442 · Cited by 620
A deep learning approach for ECG-based heartbeat classification for arrhythmia detection
Sannino, G., & De Pietro, G. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.03.057 · Cited by 445
Anomaly detection in ECG time signals via deep long short-term memory networks
Chauhan, S., & Vig, L. (2015) · 2015 IEEE International Conference on Data Science and Advanced Analytics (DSAA) · doi:10.1109/dsaa.2015.7344872 · Cited by 405
A deep convolutional neural network model for automated identification of abnormal EEG signals
Yıldırım, Ö., Baloglu, U. B., & Acharya, U. R. (2020) · Neural Computing and Applications · doi:10.1007/s00521-018-3889-z · Cited by 211
Data driven discovery of cyber physical systems
Yuan, Y., Tang, X., Zhou, W., Pan, W., Li, X., Zhang, H.-T., Ding, H., & Goncalves, J. (2019) · Nature Communications · doi:10.1038/s41467-019-12490-1 · Cited by 196
Self-citationAttia, Z. I., Kapa, S., Yao, X., Lopez‐Jimenez, F., Mohan, T. L., Pellikka, P. A., Carter, R. E., Shah, N. D., Friedman, P. A., & Noseworthy, P. A. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13889 · Cited by 196
Data driven discovery of cyber physical systems
Yuan, Y., Tang, X., Zhou, W. J., Pan, W. L., Li, X., Zhang, H., Ding, H., & Gonçalves, J. M. (2019) · Apollo (University of Cambridge) · doi:10.17863/cam.43852 · Cited by 165
Self-citationMisdiagnosis of atrial fibrillation and its clinical consequences
Bogun, F., Anh, D., Kalahasty, G., Wissner, E., Bou Serhal, C., Bazzi, R., Douglas Weaver, W., & Schuger, C. (2004) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.06.024 · Cited by 165
Huang, P., Lin, C. T., Li, Y., Tammemagi, M. C., Brock, M. V., Atkar-Khattra, S., Xu, Y., Hu, P., Mayo, J. R., Schmidt, H., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30159-1 · Cited by 148
Self-citationMachine learning in the electrocardiogram
Mincholé, A., Camps, J., Lyon, A., & Rodríguez, B. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.08.008 · Cited by 147
Misdiagnosis of Long QT Syndrome as Epilepsy at First Presentation
MacCormick, J. M., MCALISTER, H. F., Crawford, J., French, J. K., Crozier, I., Shelling, A. N., Eddy, C.-A., Rees, M. I., & Skinner, J. R. (2009) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2009.01.031 · Cited by 145
Schlant, R. C., Adolph, R. J., Dimarco, J., Dreifus, L. S., DUNN, M. I., Fisch, C., Garson, A., Haywood, L. J., Levine, H. J., & Murray, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.1221 · Cited by 119
Patient-Specific ECG Classification Based on Recurrent Neural Networks and Clustering Technique
Zhang, C., Wang, G., Zhao, J., Gao, P., Lin, J., & Yang, H. (2017) · Biomedical Engineering · doi:10.2316/p.2017.852-029 · Cited by 113
Kamaleswaran, R., Mahajan, R., & Akbilgic, O. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaaa9d · Cited by 105
A confident decision support system for interpreting electrocardiograms
Holst, H., Ohlsson, M., Peterson, C., & Edenbrandt, L. (1999) · Clinical Physiology · doi:10.1046/j.1365-2281.1999.00195.x · Cited by 70
Management of common arrhythmias and conduction abnormalities
Kannankeril, P. J., & Fish, F. A. (2003) · Progress in Pediatric Cardiology · doi:10.1016/s1058-9813(03)00014-6 · Cited by 13
Cited by
Artificial intelligence-enhanced electrocardiography in cardiovascular disease management
Siontis, K. C., Noseworthy, P. A., Attia, Z. I., & Friedman, P. A. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00503-2 · Cited by 914
Cen, L.-P., Ji, J., Lin, J.-W., Ju, S.-T., Lin, H.-J., Li, T.-P., Wang, Y., Yang, J.-F., Liu, Y.-F., Tan, S., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25138-w · Cited by 346
Self-citationClassifying Cardiac Arrhythmia from ECG Signal Using 1D CNN Deep Learning Model
Ahmed, A. A., Ali, W., Abdullah, T. A. A., & Malebary, S. J. (2023) · Mathematics · doi:10.3390/math11030562 · Cited by 193
Interpretable deep learning for automatic diagnosis of 12-lead electrocardiogram
Zhang, D., Yang, S., Yuan, X., & Zhang, P. (2021) · iScience · doi:10.1016/j.isci.2021.102373 · Cited by 189
“applied a deep learning algorithm to 12-lead ECGs to diagnosis 20 types of cardiac abnormalities, and the model performance exceeded physicians trained in ECG interpretation (Zhu et al., 2020).”
BackgroundMethodAccessory pathway analysis using a multimodal deep learning model
Nishimori, M., Kiuchi, K., Nishimura, K., Kusano, K., Yoshida, A., Adachi, K., Hirayama, Y., Miyazaki, Y., Fujiwara, R., Sommer, P., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-87631-y · Cited by 36
Metadata
- Authors
- Zhu, H., Cheng, C., Yin, H., Li, X., Zuo, P., Ding, J., Lin, F., Wang, J., Zhou, B., Li, Y., Hu, S., Xiong, Y., Wang, B., Wan, G., Yang, X., & Yuan, Y.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 2
- Issue
- 7
- Pages
- e348-e357
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W3032941608
- Cited by
- 204
- References
- 28
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.