A deep learning algorithm to detect anaemia with ECGs: a retrospective, multicentre study
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Anaemia is an important health-care burden globally, and screening for anaemia is crucial to prevent multi-organ injury, irreversible complications, and life-threatening adverse events. We aimed to establish whether a deep learning algorithm (DLA) that enables non-invasive anaemia screening from electrocardiograms (ECGs) might improve the detection of anaemia. METHODS: We did a retrospective, multicentre, diagnostic study in which a DLA was developed using ECGs and then internally and externally validated. We used data from two hospitals, Sejong General Hospital (hospital A) and Mediplex Sejong Hospital (hospital B), in South Korea. Data from hospital A was for DLA development and internal validation, and data from hospital B was for external validation. We included individuals who had at least one ECG with a haemoglobin measurement within 1 h of the index ECG and excluded individuals with missing demographic, electrocardiographic, or haemoglobin information. Three types of DLA were developed with 12-lead, 6-lead (limb lead), and single-lead (lead I) ECGs to detect haemoglobin concentrations of 10 g/dL or less. The DLA was built by a convolutional neural network and used 500-Hz raw ECG, age, and sex as input data. FINDINGS: The study period ran from Oct 1, 2016, to Sept 30, 2019, in hospital A and March 1, 2017, to Sept 30, 2019, in hospital B. 40 513 patients at hospital A and 4737 patients at hospital B were eligible for inclusion. We excluded 281 patients at hospital A and 72 patients at hospital B because of missing values for clinical information and ECG data. The development dataset comprised 57 435 ECGs from 31 898 patients, and the algorithm was internally validated with 7974 ECGs from 7974 patients. The external validation dataset included 4665 ECGs from 4665 patients. 586 (internal) and 194 (external) patients within the combined dataset were found to be anaemic. During internal and external validation, the area under the receiver operating characteristics curve (AUROC) of the DLA using a 12-lead ECG for detecting anaemia was 0·923 for internal validation and 0·901 for external validation. Using a 90% sensitivity operating point for the development data, the sensitivity, specificity, negative predictive value, and positive predictive value of internal validation were 89·8%, 81·5%, 99·4%, and 20·0%, respectively, and those of external validation were 86·1%, 76·2%, 99·2%, and 13·5%, respectively. The DLA focused on the QRS complex for deciding the presence of anaemia in a sensitivity map. The AUROCs of DLAs using 6 leads and a single lead were in the range of 0·841-0·890. INTERPRETATION: In this study, using raw ECG data, a DLA accurately detected anaemia. The application of artificial intelligence to ECGs could enable screening for anaemia. FUNDING: None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
Saito, T., & Rehmsmeier, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118432 · Cited by 5,309
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Mittelstadt, B., Russell, C., & Wachter, S. (2019) · Proceedings of the Conference on Fairness, Accountability, and Transparency · doi:10.1145/3287560.3287574 · Cited by 794
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Is anemia a new cardiovascular risk factor?
Kaiafa, G., Kanellos, I., Savopoulos, C., Kakaletsis, N., Giannakoulas, G., & Hatzitolios, A. I. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.159 · Cited by 92
Cited by
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
“While a small number of studies have adopted a strategy that uses salient maps to improve interpretability, 98,113 such attempts are still difficult to find compared to the models in the field of medical imaging.”
Kwon, J.-M., Kim, K.-H., Eisen, H. J., Cho, Y., Jeon, K.-H., Lee, S. Y., Park, J., & Oh, B.-H. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaa015 · Cited by 82
Self-citationMultimodal deep learning enhances diagnostic precision in left ventricular hypertrophy
Soto, J. T., Weston Hughes, J., Sanchez, P. A., Perez, M., Ouyang, D., & Ashley, E. A. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac033 · Cited by 76
Deep learning evaluation of biomarkers from echocardiogram videos
Hughes, J. W., Yuan, N., He, B., Ouyang, J., Ebinger, J., Botting, P., Lee, J., Theurer, J., Tooley, J. E., Nieman, K., et al. (2021) · EBioMedicine · doi:10.1016/j.ebiom.2021.103613 · Cited by 71
Ouyang, D., Theurer, J., Stein, N. R., Hughes, J. W., Elias, P., He, B., Yuan, N., Duffy, G., Sandhu, R. K., Ebinger, J., et al. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00220-0 · Cited by 64
Metadata
- Authors
- Kwon, J.-M., Cho, Y., Jeon, K.-H., Cho, S., Kim, K.-H., Baek, S. D., Jeung, S., Park, J., & Oh, B.-H.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 2
- Issue
- 7
- Pages
- e358-e367
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W3038123542
- Cited by
- 116
- References
- 8
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A deep learning algorithm to detect anaemia with ECGs: a retrospective, multicentre study. https://app.cochat.ai/papers/10.1016/s2589-7500(20)30108-4
- The paper
- Kwon, J.-M., Cho, Y., Jeon, K.-H., Cho, S., Kim, K.-H., Baek, S. D., Jeung, S., Park, J., & Oh, B.-H. (2020). A deep learning algorithm to detect anaemia with ECGs: a retrospective, multicentre study. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(20)30108-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.