Combining the strengths of radiologists and AI for breast cancer screening: a retrospective analysis

Open access

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

BACKGROUND: We propose a decision-referral approach for integrating artificial intelligence (AI) into the breast-cancer screening pathway, whereby the algorithm makes predictions on the basis of its quantification of uncertainty. Algorithmic assessments with high certainty are done automatically, whereas assessments with lower certainty are referred to the radiologist. This two-part AI system can triage normal mammography exams and provide post-hoc cancer detection to maintain a high degree of sensitivity. This study aimed to evaluate the performance of this AI system on sensitivity and specificity when used either as a standalone system or within a decision-referral approach, compared with the original radiologist decision. METHODS: We used a retrospective dataset consisting of 1 193 197 full-field, digital mammography studies carried out between Jan 1, 2007, and Dec 31, 2020, from eight screening sites participating in the German national breast-cancer screening programme. We derived an internal-test dataset from six screening sites (1670 screen-detected cancers and 19 997 normal mammography exams), and an external-test dataset of breast cancer screening exams (2793 screen-detected cancers and 80 058 normal exams) from two additional screening sites to evaluate the performance of an AI algorithm on sensitivity and specificity when used either as a standalone system or within a decision-referral approach, compared with the original individual radiologist decision at the point-of-screen reading ahead of the consensus conference. Different configurations of the AI algorithm were evaluated. To account for the enrichment of the datasets caused by oversampling cancer cases, weights were applied to reflect the actual distribution of study types in the screening programme. Triaging performance was evaluated as the rate of exams correctly identified as normal. Sensitivity across clinically relevant subgroups, screening sites, and device manufacturers was compared between standalone AI, the radiologist, and decision referral. We present receiver operating characteristic (ROC) curves and area under the ROC (AUROC) to evaluate AI-system performance over its entire operating range. Comparison with radiologists and subgroup analysis was based on sensitivity and specificity at clinically relevant configurations. FINDINGS: The exemplary configuration of the AI system in standalone mode achieved a sensitivity of 84·2% (95% CI 82·4-85·8) and a specificity of 89·5% (89·0-89·9) on internal-test data, and a sensitivity of 84·6% (83·3-85·9) and a specificity of 91·3% (91·1-91·5) on external-test data, but was less accurate than the average unaided radiologist. By contrast, the simulated decision-referral approach significantly improved upon radiologist sensitivity by 2·6 percentage points and specificity by 1·0 percentage points, corresponding to a triaging performance at 63·0% on the external dataset; the AUROC was 0·982 (95% CI 0·978-0·986) on the subset of studies assessed by AI, surpassing radiologist performance. The decision-referral approach also yielded significant increases in sensitivity for a number of clinically relevant subgroups, including subgroups of small lesion sizes and invasive carcinomas. Sensitivity of the decision-referral approach was consistent across the eight included screening sites and three device manufacturers. INTERPRETATION: The decision-referral approach leverages the strengths of both the radiologist and AI, demonstrating improvements in sensitivity and specificity surpassing that of the individual radiologist and of the standalone AI system. This approach has the potential to improve the screening accuracy of radiologists, is adaptive to the requirements of screening, and could allow for the reduction of workload ahead of the consensus conference, without discarding the generalised knowledge of radiologists. FUNDING: Vara.

Verifying this paper

7 of 9 steps done · this page updates itself — you can leave and come back

  1. Registry recordVerified
  2. Full textRead the full text
  3. Reference listQueued — the list appears here once it is fetched
  4. Reference checkChecking each cited work
  5. StatisticsNeeds the full text
  6. ClaimsNeeds the full text
  7. Cited sourcesNeeds claims to check
  8. Self-checkNeeds the full text
  9. VerificationFindings verified

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(22)00070-x

Cites

28 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1: Comparison between the decision-referral and standalone AI pathway in double-reader screening settings Different possible screening pathways are presented. (A) The existing screening pathway, in which mammography studies are independently reviewed by two readers and discordant findings are resolved during consensus. (B) The standalone AI pathway, the most commonly proposed implementation pathway for AI systems. Standalone is defined by the taking over of all decisions from one radiologist, sometimes also referred to as an independent read. (C) The decision-referral pathway, which is the focus of this evaluation. All mammography studies are first read by the AI system, and predictions are produced. AI=artificial intelligence. *The model exhibits a score between 0·0 and 1·0 indicating the malignancy of a study. Scores lower than the threshold for negative predictions (triaged as normal) or higher than the threshold for positive predictions (safety net) were considered confident. All other scores between the two thresholds were not considered confident and the corresponding studies were referred to the radiologist. †Decision-referral approach when used by a single reader in a double reader setting.
Figure 1: Comparison between the decision-referral and standalone AI pathway in double-reader screening settings Different possible screening pathways are presented. (A) The existing screening pathway, in which mammography studies are independently reviewed by two readers and discordant findings are resolved during consensus. (B) The standalone AI pathway, the most commonly proposed implementation pathway for AI systems. Standalone is defined by the taking over of all decisions from one radiologist, sometimes also referred to as an independent read. (C) The decision-referral pathway, which is the focus of this evaluation. All mammography studies are first read by the AI system, and predictions are produced. AI=artificial intelligence. *The model exhibits a score between 0·0 and 1·0 indicating the malignancy of a study. Scores lower than the threshold for negative predictions (triaged as normal) or higher than the threshold for positive predictions (safety net) were considered confident. All other scores between the two thresholds were not considered confident and the corresponding studies were referred to the radiologist. †Decision-referral approach when used by a single reader in a double reader setting.CC BY · PubMed Central
Figure 2: Dataset partitions Further information about study inclusion criteria, the German national breast-cancer screening programme, and the sample weighting technique is available in the appendix (p 6). *Subsample normal mammography exams, one study per woman.
Figure 2: Dataset partitions Further information about study inclusion criteria, the German national breast-cancer screening programme, and the sample weighting technique is available in the appendix (p 6). *Subsample normal mammography exams, one study per woman.CC BY · PubMed Central
Figure 3: Comparison of the performance of standalone and decision-referral approaches based on the internal-test dataset Overall screening diagnostic accuracy for radiologists, standalone AI, and decision referral are presented. Sensitivity and specificity are given for radiologists (red), standalone AI (purple), and decision referral (green for the exemplary configuration NT@97%+SN@98% and blue for alternative configurations). In addition, we present ROC curves and AUROC to evaluate AI-system performance over its entire operating range on the internal-test dataset (n=21 667; A) and on the subset of data for which it is able to produce its most confident predictions for the exemplary configuration NT@97%+SN@98% (B). Error bars denote 95% CIs. The decision-referral approach outperformed the independent radiologist on either or both sensitivity and specificity depending on the configuration (A) by surpassing the radiologist throughout on the confident set of predictions (B). The resulting sensitivity and specificity values for all studies were similar or greater than the radiologist alone, whereas 42·1–71·1% of studies were able to be safely triaged. AI=artificial intelligence. AUC=area under the curve. AUROC=area under the receiver-operating characteristic. NT=normal triage. ROC=receiver-operating characteristic. SN=safety net.
Figure 3: Comparison of the performance of standalone and decision-referral approaches based on the internal-test dataset Overall screening diagnostic accuracy for radiologists, standalone AI, and decision referral are presented. Sensitivity and specificity are given for radiologists (red), standalone AI (purple), and decision referral (green for the exemplary configuration NT@97%+SN@98% and blue for alternative configurations). In addition, we present ROC curves and AUROC to evaluate AI-system performance over its entire operating range on the internal-test dataset (n=21 667; A) and on the subset of data for which it is able to produce its most confident predictions for the exemplary configuration NT@97%+SN@98% (B). Error bars denote 95% CIs. The decision-referral approach outperformed the independent radiologist on either or both sensitivity and specificity depending on the configuration (A) by surpassing the radiologist throughout on the confident set of predictions (B). The resulting sensitivity and specificity values for all studies were similar or greater than the radiologist alone, whereas 42·1–71·1% of studies were able to be safely triaged. AI=artificial intelligence. AUC=area under the curve. AUROC=area under the receiver-operating characteristic. NT=normal triage. ROC=receiver-operating characteristic. SN=safety net.CC BY · PubMed Central
Figure 4: Comparison of the performance of standalone and decision-referral approaches based on the external-test dataset Overall screening diagnostic accuracy for radiologists, standalone AI, and decision referral are presented. Sensitivity and specificity are given for radiologists (red), standalone AI (purple), and decision referral (green for the exemplary configuration NT@97%+SN@98% and blue for alternative configurations). In addition, we present ROC curves and AUROC to evaluate AI-system performance over its entire operating range on the external-test set (n=82 851; A) and on the subset of data for which it is able to produce its most confident predictions for the exemplary configuration NT@97%+SN@98% (B). Error bars denote 95% CIs. The decision-referral approach outperformed the independent radiologist on either or both sensitivity and specificity depending on the configuration (A) by surpassing the radiologist throughout on the confident set of predictions (B). The resulting sensitivity and specificity values for all studies were similar or greater than the radiologist alone, whereas 44·5–73·8% of studies were able to be safely triaged. AI=artificial intelligence. AUC=area under the curve. AUROC=area under the receiver-operating characteristic. NT=normal triage. ROC=receiver-operating characteristic. SN=safety net.
Figure 4: Comparison of the performance of standalone and decision-referral approaches based on the external-test dataset Overall screening diagnostic accuracy for radiologists, standalone AI, and decision referral are presented. Sensitivity and specificity are given for radiologists (red), standalone AI (purple), and decision referral (green for the exemplary configuration NT@97%+SN@98% and blue for alternative configurations). In addition, we present ROC curves and AUROC to evaluate AI-system performance over its entire operating range on the external-test set (n=82 851; A) and on the subset of data for which it is able to produce its most confident predictions for the exemplary configuration NT@97%+SN@98% (B). Error bars denote 95% CIs. The decision-referral approach outperformed the independent radiologist on either or both sensitivity and specificity depending on the configuration (A) by surpassing the radiologist throughout on the confident set of predictions (B). The resulting sensitivity and specificity values for all studies were similar or greater than the radiologist alone, whereas 44·5–73·8% of studies were able to be safely triaged. AI=artificial intelligence. AUC=area under the curve. AUROC=area under the receiver-operating characteristic. NT=normal triage. ROC=receiver-operating characteristic. SN=safety net.CC BY · PubMed Central
Figure 5: Subgroup performance on sensitivity at exemplary configuration on external-test data Average sensitivities for exemplary configurations of the decision-referral approach (dashed green line, NT@0·97+SN@0·98), are higher than both the average radiologist sensitivity (solid red line) and standalone AI average sensitivity (dashed purple line, configuration as in table). Bar plots show sensitivities stratified across relevant subgroups. Accompanying values are available in the appendix (p 9). AI=artificial intelligence. ns=not significant. NT=normal triaging. SN=safety net. ****p≤0·001. ***p≤0·001. **p≤0·01. *p≤0·05.
Figure 5: Subgroup performance on sensitivity at exemplary configuration on external-test data Average sensitivities for exemplary configurations of the decision-referral approach (dashed green line, NT@0·97+SN@0·98), are higher than both the average radiologist sensitivity (solid red line) and standalone AI average sensitivity (dashed purple line, configuration as in table). Bar plots show sensitivities stratified across relevant subgroups. Accompanying values are available in the appendix (p 9). AI=artificial intelligence. ns=not significant. NT=normal triaging. SN=safety net. ****p≤0·001. ***p≤0·001. **p≤0·01. *p≤0·05.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Hofvind S, Ponti A, Patnick J, False-positive results in mammographic screening for breast cancer in Europe: a literature review and survey of service screening programmes. J Med Screening 2012; 19 (suppl 1): 57– 66. 22972811 · doi:10.1258/jms.2012.012083

Cited by

See all 273

Metadata

Authors
Leibig, C., Brehmer, M., Bunk, S., Byng, D., Pinker, K., & Umutlu, L.
Affiliations
  • Essen University Hospital (DE)
  • Memorial Sloan Kettering Cancer Center (US)
Corresponding author
Leibig, Christian
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2022-07
Volume
4
Issue
7
Pages
e507-e519
ISSN
2589-7500 (ISSN-L)
OpenAlex
W4283272038
Cited by
273
References
29
Citations by year
2026: 56 · 2025: 70 · 2024: 51 · 2023: 80 · 2022: 16
FWCI
11.88
Type
journal article
Language
en
Open access
Licence
Locations
  • The Lancet Digital Health (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion, cc-by)
Funders
European Commission
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
breast cancer screening, artificial intelligence, mammography, radiologist performance, sensitivity and specificity, full-field digital mammography, AI-assisted reading, consensus conference, subgroup analysis, screen-detected cancer, false positive reduction, false negative reduction
MeSH terms
Radiologists, Artificial Intelligence, Breast Neoplasms, Female, Humans, Retrospective Studies, Early Detection of Cancer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.