Combining the strengths of radiologists and AI for breast cancer screening: a retrospective analysis
Open accessThe DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
BACKGROUND: We propose a decision-referral approach for integrating artificial intelligence (AI) into the breast-cancer screening pathway, whereby the algorithm makes predictions on the basis of its quantification of uncertainty. Algorithmic assessments with high certainty are done automatically, whereas assessments with lower certainty are referred to the radiologist. This two-part AI system can triage normal mammography exams and provide post-hoc cancer detection to maintain a high degree of sensitivity. This study aimed to evaluate the performance of this AI system on sensitivity and specificity when used either as a standalone system or within a decision-referral approach, compared with the original radiologist decision. METHODS: We used a retrospective dataset consisting of 1 193 197 full-field, digital mammography studies carried out between Jan 1, 2007, and Dec 31, 2020, from eight screening sites participating in the German national breast-cancer screening programme. We derived an internal-test dataset from six screening sites (1670 screen-detected cancers and 19 997 normal mammography exams), and an external-test dataset of breast cancer screening exams (2793 screen-detected cancers and 80 058 normal exams) from two additional screening sites to evaluate the performance of an AI algorithm on sensitivity and specificity when used either as a standalone system or within a decision-referral approach, compared with the original individual radiologist decision at the point-of-screen reading ahead of the consensus conference. Different configurations of the AI algorithm were evaluated. To account for the enrichment of the datasets caused by oversampling cancer cases, weights were applied to reflect the actual distribution of study types in the screening programme. Triaging performance was evaluated as the rate of exams correctly identified as normal. Sensitivity across clinically relevant subgroups, screening sites, and device manufacturers was compared between standalone AI, the radiologist, and decision referral. We present receiver operating characteristic (ROC) curves and area under the ROC (AUROC) to evaluate AI-system performance over its entire operating range. Comparison with radiologists and subgroup analysis was based on sensitivity and specificity at clinically relevant configurations. FINDINGS: The exemplary configuration of the AI system in standalone mode achieved a sensitivity of 84·2% (95% CI 82·4-85·8) and a specificity of 89·5% (89·0-89·9) on internal-test data, and a sensitivity of 84·6% (83·3-85·9) and a specificity of 91·3% (91·1-91·5) on external-test data, but was less accurate than the average unaided radiologist. By contrast, the simulated decision-referral approach significantly improved upon radiologist sensitivity by 2·6 percentage points and specificity by 1·0 percentage points, corresponding to a triaging performance at 63·0% on the external dataset; the AUROC was 0·982 (95% CI 0·978-0·986) on the subset of studies assessed by AI, surpassing radiologist performance. The decision-referral approach also yielded significant increases in sensitivity for a number of clinically relevant subgroups, including subgroups of small lesion sizes and invasive carcinomas. Sensitivity of the decision-referral approach was consistent across the eight included screening sites and three device manufacturers. INTERPRETATION: The decision-referral approach leverages the strengths of both the radiologist and AI, demonstrating improvements in sensitivity and specificity surpassing that of the individual radiologist and of the standalone AI system. This approach has the potential to improve the screening accuracy of radiologists, is adaptive to the requirements of screening, and could allow for the reduction of workload ahead of the consensus conference, without discarding the generalised knowledge of radiologists. FUNDING: Vara.
Verifying this paper
7 of 9 steps done · this page updates itself — you can leave and come back
- Registry recordVerified
- Full textRead the full text
- Reference listQueued — the list appears here once it is fetched
- Reference checkChecking each cited work
- StatisticsNeeds the full text
- ClaimsNeeds the full text
- Cited sourcesNeeds claims to check
- Self-checkNeeds the full text
- VerificationFindings verified
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
An Introduction to Statistical Learning
James, G., Witten, D., Hastie, T., & Tibshirani, R. (2013) · Springer Texts in Statistics · doi:10.1007/978-1-4614-7138-7 · Cited by 12,106
Simple and Scalable Predictive Uncertainty Estimation using Deep Ensembles
Lakshminarayanan, B., Pritzel, A., & Blundell, C. (2016) · arXiv · doi:10.48550/arxiv.1612.01474 · Cited by 3,666 · cited 1×
“Furthermore, decision referral maintained or improved radiologist specificity across all device manufacturers (appendix pp 16, 17).”
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Shortcut learning in deep neural networks
Geirhos, R., Jacobsen, J.-H., Michaelis, C., Zemel, R., Brendel, W., Bethge, M., & Wichmann, F. A. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00257-z · Cited by 2,224 · cited 1×
“To verify that the achieved performance of the algorithm was not caused by shortcut learning 19 from signals specific to those six screening sites, but rather generalised to different screening sites, we supplemented this evaluation with an evaluation on out-of-distribution data from two additional…”
European guidelines for quality assurance in breast cancer screening and diagnosis
Amendoeira, I., Perry, N., Broeders, M. J. M., de Wolf, C., Törnberg, S., Holland, R. D., & von Karsa, L. (2013) · Zurich Open Repository and Archive (University of Zurich) · doi:10.2772/13196 · Cited by 1,556
Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., & von Karsa, L. (2008) · Annals of Oncology · doi:10.1093/annonc/mdm481 · Cited by 1,020
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Deep Neural Networks Improve Radiologists’ Performance in Breast Cancer Screening
Wu, N., Phang, J., Park, J., Shen, Y., Huang, Z., Zorin, M., Jastrzebski, S., Fevry, T., Katsnelson, J., Kim, E., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945514 · Cited by 689 · cited 2×
“7,8 However, a major drawback of such an approach is the necessity for the radiologist to evaluate all studies, and thus the workload of the radiologist is not alleviated by AI.”
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678 · cited 1×
“31 With more accurate, confident AI predictions and referred studies (with a cancer prevalence being similar to the overall population), the decision-referral approach is promising.”
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525 · cited 1×
“…of lesions on the basis of digital mammography data have shown that such systems have comparable diagnostic performance to radiologists and are promising as decision support systems, 2–8 but the current evidence is insufficient to judge accuracy within breast-cancer screening programmes.”
BI-RADS Lexicon for US and Mammography: Interobserver Variability and Positive Predictive Value
Lazarus, E., Mainiero, M. B., Schepps, B., Koelliker, S. L., & Livingston, L. S. (2006) · Radiology · doi:10.1148/radiol.2392042127 · Cited by 511 · cited 1×
“29,30 Fully automated AI does not ameliorate this challenge; ambiguous AI predictions would still result in large numbers of false positives and increased workload.”
Leveraging uncertainty information from deep neural networks for disease detection
Leibig, C., Allken, V., Ayhan, M. S., Berens, P., & Wahl, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-17876-z · Cited by 510 · cited 1×
“Furthermore, decision referral maintained or improved radiologist specificity across all device manufacturers (appendix pp 16, 17).”
Self-citationMansournia, M. A., & Altman, D. G. (2016) · BMJ · doi:10.1136/bmj.i189 · Cited by 433 · cited 1×
“To account for the enrichment of each dataset caused by oversampled cancer cases, we used a weighting technique 20,21 to ensure the test datasets were reflective of a real screening population (appendix p 6).”
Schaffter, T., Buist, D. S. M., Lee, C. I., Nikulin, Y., Ribli, D., Guan, Y., Lotter, W., Jie, Z., Du, H., Wang, S., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.0265 · Cited by 409 · cited 1×
“7,8 However, a major drawback of such an approach is the necessity for the radiologist to evaluate all studies, and thus the workload of the radiologist is not alleviated by AI.”
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338 · cited 4×
“Exact values are provided in the appendix (pp 9, 12, 13).”
InfluentialDembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290 · cited 2×
“10–15 These studies, however, showed that sizable reductions of screening exams from the radiologist workload might come at an unacceptable reduction of sensitivity.”
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
A Deep Learning Model to Triage Screening Mammograms: A Simulation Study
Yala, A., Schuster, T., Miles, R., Barzilay, R., & Lehman, C. (2019) · Radiology · doi:10.1148/radiol.2019182908 · Cited by 210 · cited 2×
“Exact values are provided in the appendix (pp 9, 12, 13).”
Raya-Povedano, J. L., Romero-Martín, S., Elías-Cabot, E., Gubern-Mérida, A., Rodríguez-Ruiz, A., & Álvarez-Benito, M. (2021) · Radiology · doi:10.1148/radiol.2021203555 · Cited by 177 · cited 2×
“Exact values are provided in the appendix (pp 9, 12, 13).”
Identifying normal mammograms in a large screening population using artificial intelligence
Lång, K., Dustler, M., Dahlblom, V., Åkesson, A., Andersson, I., & Zackrisson, S. (2020) · European Radiology · doi:10.1007/s00330-020-07165-1 · Cited by 137 · cited 1×
“10–15 These studies, however, showed that sizable reductions of screening exams from the radiologist workload might come at an unacceptable reduction of sensitivity.”
An Introduction to the Bootstrap
Grimshaw, S. D. (1995) · Technometrics · doi:10.1080/00401706.1995.10484340 · Cited by 120
Breast Density: Clinical Implications and Assessment Methods
Winkler, N. S., Raza, S., Mackesy, M. M., & Birdwell, R. L. (2015) · Radiographics · doi:10.1148/rg.352140134 · Cited by 110
Improving Workflow Efficiency for Mammography Using Machine Learning
Kyono, T., Gilbert, F. J., & van der Schaar, M. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.05.012 · Cited by 90
Forester, N., Lowes, S., Mitchell, E., & Twiddy, M. (2018) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2018.12.008 · Cited by 82 · cited 1×
“23,24,26 Generalisability was similarly assessed by comparing results on the internal validation and test datasets, and by presenting sensitivity stratified across screening sites and device manufacturers, and specificity stratified across device manufacturers.”
Balta, C., Rodríguez‐Ruiz, A., Mieskes, C., Karssemeijer, N., & Heywang-Köbrunner, S. H. (2020) · International Workshop on Breast Imaging (IWBI) · doi:10.1117/12.2564179 · Cited by 22
Enriched designs for assessing discriminatory performance — analysis of bias and variance
Pinsky, P. F., & Gallas, B. D. (2011) · Statistics in Medicine · doi:10.1002/sim.4432 · Cited by 7
Research works printed but not linked: 1
- Hofvind S, Ponti A, Patnick J, False-positive results in mammographic screening for breast cancer in Europe: a literature review and survey of service screening programmes. J Med Screening 2012; 19 (suppl 1): 57– 66. 22972811 · doi:10.1258/jms.2012.012083
Cited by
Dembrower, K., Crippa, A., Colón, E., Eklund, M., & Strand, F. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00153-x · Cited by 358
Eisemann, N., Bunk, S., Mukama, T., Baltus, H., Elsner, S. A., Gomille, T., Hecht, G., Heywang-Köbrunner, S., Rathmann, R., Siegmann-Luz, K., et al. (2025) · Nature Medicine · doi:10.1038/s41591-024-03408-6 · Cited by 217
Self-citationYoon, J. H., Strand, F., Baltzer, P. A. T., Conant, E. F., Gilbert, F. J., Lehman, C. D., Morris, E. A., Mullen, L. A., Nishikawa, R. M., Sharma, N., et al. (2023) · Radiology · doi:10.1148/radiol.222639 · Cited by 198
Dvijotham, K., Winkens, J., Barsbey, M., Ghaisas, S., Stanforth, R., Pawlowski, N., Strachan, P., Ahmed, Z., Azizi, S., Bachrach, Y., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02437-x · Cited by 120
The Future of AI and Informatics in Radiology: 10 Predictions
Langlotz, C. P. (2023) · Radiology · doi:10.1148/radiol.231114 · Cited by 56
Metadata
- Authors
- Leibig, C., Brehmer, M., Bunk, S., Byng, D., Pinker, K., & Umutlu, L.
- Affiliations
- Essen University Hospital (DE)
- Memorial Sloan Kettering Cancer Center (US)
- Corresponding author
- Leibig, Christian
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2022-07
- Volume
- 4
- Issue
- 7
- Pages
- e507-e519
- ISSN
- 2589-7500 (ISSN-L)
- PMC
- PMC9839981
- OpenAlex
- W4283272038
- Semantic Scholar
- 3bfa099aafd426086952a65ee537537f2ec6cc8c
- Cited by
- 273
- References
- 29
- Citations by year
- 2026: 56 · 2025: 70 · 2024: 51 · 2023: 80 · 2022: 16
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- The Lancet Digital Health (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion, cc-by)
- Funders
- European Commission
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- breast cancer screening, artificial intelligence, mammography, radiologist performance, sensitivity and specificity, full-field digital mammography, AI-assisted reading, consensus conference, subgroup analysis, screen-detected cancer, false positive reduction, false negative reduction
- MeSH terms
- Radiologists, Artificial Intelligence, Breast Neoplasms, Female, Humans, Retrospective Studies, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.