Comparison of seven commercial SARS-CoV-2 rapid point-of-care antigen tests: a single-centre laboratory evaluation study
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Antigen point-of-care tests (AgPOCTs) can accelerate SARS-CoV-2 testing. As some AgPOCTs have become available, interest is growing in their utility and performance. Here we aimed to compare the analytical sensitivity and specificity of seven commercially available AgPOCT devices. METHODS: In a single-centre, laboratory evaluation study, we compared AgPOCT products from seven suppliers: the Abbott Panbio COVID-19 Ag Rapid Test, the RapiGEN BIOCREDIT COVID-19 Ag, the Healgen Coronavirus Ag Rapid Test Cassette (Swab), the Coris BioConcept COVID-19 Ag Respi-Strip, the R-Biopharm RIDA QUICK SARS-CoV-2 Antigen, the nal von minden NADAL COVID-19 Ag Test, and the Roche-SD Biosensor SARS-CoV Rapid Antigen Test. Tests were evaluated on recombinant SARS-CoV-2 nucleoprotein, cultured endemic and emerging coronaviruses, stored respiratory samples with known SARS-CoV-2 viral loads, stored samples from patients with respiratory pathogens other than SARS-CoV-2, and self-sampled swabs from healthy volunteers. We estimated analytical sensitivity in terms of approximate viral concentrations (quantified by real-time RT-PCR) that yielded positive AgPOCT results, and specificity in terms of propensity to generate false-positive results. FINDINGS: copies per swab. The assays showed no cross-reactivity towards cell culture or tissue culture supernatants containing any of the four endemic human coronaviruses (HCoV‑229E, HCoV‑NL63, HCoV‑OC43, or HCoV‑HKU1) or MERS-CoV, with the exception of the Healgen assay in one repeat test on HCoV-HKU1 supernatant. SARS-CoV was cross-detected by all assays. Cumulative specificities among stored clinical samples with non-SARS-CoV-2 infections (n=100) and self-samples from healthy volunteers (n=35; cumulative sample n=135) ranged between 98·5% (95% CI 94·2-99·7) and 100·0% (97·2-100·0) in five products, with two outliers at 94·8% (89·2-97·7; R-Biopharm) and 88·9% (82·1-93·4; Healgen). False-positive results did not appear to be associated with any specific respiratory pathogen. INTERPRETATION: The sensitivity range of most AgPOCTs overlaps with SARS-CoV-2 viral loads typically observed in the first week of symptoms, which marks the infectious period in most patients. The AgPOCTs with limit of detections that approximate virus concentrations at which patients are infectious might enable shortcuts in decision making in various areas of health care and public health. FUNDING: EU's Horizon 2020 research and innovation programme, German Ministry of Research, German Federal Ministry for Economic Affairs and Energy, German Ministry of Health, and Bill & Melinda Gates Foundation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
Self-citationVirological assessment of hospitalized patients with COVID-2019
Wölfel, R., Corman, V. M., Guggemos, W., Seilmaier, M., Zange, S., Müller, M. A., Niemeyer, D., Jones, T. C., Vollmar, P., Rothe, C., et al. (2020) · Nature · doi:10.1038/s41586-020-2196-x · Cited by 6,661 · cited 3×
“Due to the rapid change of viral load in the acute phase of COVID-19, 12,25 AgPOCTs have a narrow timeframe for their useful application that predominantly comprises the first week of symptoms.”
Self-citationTwo-sided confidence intervals for the single proportion: comparison of seven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<857::aid-sim777>3.0.co;2-e · Cited by 5,107
Temporal dynamics in viral shedding and transmissibility of COVID-19
He, X., Lau, E. H. Y., Wu, P., Deng, X., Wang, J., Hao, X., Lau, Y. C., Wong, J. Y., Guan, Y., Tan, X., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0869-5 · Cited by 4,247
Probabilistic programming in Python using PyMC3
Salvatier, J., Wiecki, T. V., & Fonnesbeck, C. (2016) · PeerJ Computer Science · doi:10.7717/peerj-cs.55 · Cited by 2,544
Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Adriano, A., Berhane, S., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., Beese, S., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705 · Cited by 1,156
PyMC: a modern, and comprehensive probabilistic programming framework in Python
Abril-Pla, O., Andreani, V., Carroll, C., Dong, L., Fonnesbeck, C. J., Kochurov, M., Kumar, R., Lao, J., Luhmann, C. C., Martin, O. A., et al. (2023) · PeerJ Computer Science · doi:10.7717/peerj-cs.1516 · Cited by 870
van Kampen, J. J. A., van de Vijver, D. A. M. C., Fraaij, P. L. A., Haagmans, B. L., Lamers, M. M., Okba, N., van den Akker, J. P. C., Endeman, H., Gommers, D. A. M. P. J., Cornelissen, J. J., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20568-4 · Cited by 838
Rethinking Covid-19 Test Sensitivity — A Strategy for Containment
Mina, M. J., Parker, R., & Larremore, D. B. (2020) · New England Journal of Medicine · doi:10.1056/nejmp2025631 · Cited by 703
Impact of delays on effectiveness of contact tracing strategies for COVID-19: a modelling study
Kretzschmar, M. E., Rozhnova, G., Bootsma, M. C. J., van Boven, M., van de Wijgert, J. H. H. M., & Bonten, M. J. M. (2020) · The Lancet Public Health · doi:10.1016/s2468-2667(20)30157-2 · Cited by 697
Detection of a novel human coronavirus by real-time reverse-transcription polymerase chain reaction
Corman, V. M., Eckerle, I., Bleicker, T., Zaki, A., Landt, O., Eschbach-Bludau, M., van Boheemen, S., Gopal, R., Ballhause, M., Bestebroer, T. M., et al. (2012) · Eurosurveillance · doi:10.2807/ese.17.39.20285-en · Cited by 561
Self-citationEvaluation of rapid antigen test for detection of SARS-CoV-2 virus
Mak, G. C., Cheng, P. K., Lau, S. S., Wong, K. K., Lau, C., Lam, E. T., Chan, R. C., & Tsang, D. N. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104500 · Cited by 491
Dare, R. K., Fry, A. M., Chittaganpitch, M., Sawanpanyalert, P., Olsen, S. J., & Erdman, D. D. (2007) · The Journal of Infectious Diseases · doi:10.1086/521308 · Cited by 333
Pekosz, A., Parvu, V., Li, M., Andrews, J. C., Manabe, Y. C., Kodsi, S., Gary, D. S., Roger-Dalbert, C., Leitch, J., & Cooper, C. K. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1706 · Cited by 276
van Elden, L. J. R., van Loon, A. M., van Alphen, F., Hendriksen, K. A. W., Hoepelman, A. I. M., van Kraaij, M. G. J., Oosterheert, J., Schipper, P., Schuurman, R., & Nijhuis, M. (2004) · The Journal of Infectious Diseases · doi:10.1086/381207 · Cited by 225
Perera, R. A. P. M., Tso, E., Tsang, O. T. Y., Tsang, D. N. C., Fung, K., Leung, Y. W. Y., Chin, A. W. H., Chu, D. K. W., Cheng, S. M. S., Poon, L. L. M., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2611.203219 · Cited by 221
Müller, M. A., Raj, V. S., Muth, D., Meyer, B., Kallies, S., Smits, S. L., Wollny, R., Bestebroer, T. M., Specht, S., Suliman, T., et al. (2012) · mBio · doi:10.1128/mbio.00515-12 · Cited by 209
Self-citationMertens, P., De Vos, N., Martiny, D., Jassoy, C., Mirazimi, A., Cuypers, L., Van den Wijngaert, S., Monteil, V., Melin, P., Stoffels, K., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00225 · Cited by 208
Bruning, A. H. L., Leeflang, M. M. G., Vos, J. M. B. W., Spijker, R., de Jong, M. D., Wolthers, K. C., & Pajkrt, D. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/cix461 · Cited by 192
Human Coronavirus NL63 and 229E Seroconversion in Children
Dijkman, R., Jebbink, M. F., El Idrissi, N. B., Pyrc, K., Müller, M. A., Kuijpers, T. W., Zaaijer, H. L., & van der Hoek, L. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00533-08 · Cited by 185
Lindner, A. K., Nikolai, O., Kausch, F., Wintel, M., Hommes, F., Gertler, M., Krüger, L. J., Gaeddert, M., Tobian, F., Lainati, F., et al. (2021) · European Respiratory Journal · doi:10.1183/13993003.03961-2020 · Cited by 167
Self-citationLink of a ubiquitous human coronavirus to dromedary camels
Corman, V. M., Eckerle, I., Memish, Z. A., Liljander, A., Dijkman, R., Jónsdóttir, H. R., Ngeiywa, K. J. Z. J., Kamau, E., Younan, M., Masri, M. A., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1604472113 · Cited by 161
Self-citationDuration of Culturable SARS-CoV-2 in Hospitalized Patients with Covid-19
Kim, M.-C., Cui, C., Shin, K., Bae, J.-Y., Kweon, O., Lee, M.-K., Choi, S.-H., Jung, S.-Y., Park, M.-S., & Chung, J. (2021) · New England Journal of Medicine · doi:10.1056/nejmc2027040 · Cited by 153
Human Coronaviruses Associated with Upper Respiratory Tract Infections in Three Rural Areas of Ghana
Owusu, M., Sylverken, A. A., Corman, V. M., Larbi, R., Anti, P., Drexler, J. F., Agbenyega, O., Adu‐Sarkodie, Y., & Drosten, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099782 · Cited by 88
Self-citationThe explosion of new coronavirus tests that could help to end the pandemic
Guglielmi, G. (2020) · Nature · doi:10.1038/d41586-020-02140-8 · Cited by 86
SARS-CoV-2 antigen rapid immunoassay for diagnosis of COVID-19 in the emergency department
Möckel, M., Corman, V. M., Stegemann, M. S., Hofmann, J., Stein, A., Jones, T. C., Gastmeier, P., Seybold, J., Offermann, R., Bachmann, U., et al. (2021) · Biomarkers · doi:10.1080/1354750x.2021.1876769 · Cited by 86
Self-citationKrüger, L. J., Gaeddert, M., Köppel, L., Brümmer, L. E., Gottschalk, C., Miranda, I. B., Schnitzler, P., Kräusslich, H., Lindner, A. K., Nikolai, O., et al. (2020) · medRxiv · doi:10.1101/2020.10.01.20203836 · Cited by 66
Self-citationJónsdóttir, H. R., Marti, S., Geerts, D., Rodriguez, R., Thiel, V., & Dijkman, R. (2019) · Viruses · doi:10.3390/v11080747 · Cited by 18
Cited by
Estimating infectiousness throughout SARS-CoV-2 infection course
Jones, T. C., Biele, G., Mühlemann, B., Veith, T., Schneider, J., Beheim-Schwarzbach, J., Bleicker, T., Tesch, J., Schmidt, M. L., Sander, L. E., et al. (2021) · Science · doi:10.1126/science.abi5273 · Cited by 740
Self-citationSARS-CoV-2 viral load and shedding kinetics
Puhach, O., Meyer, B., & Eckerle, I. (2022) · Nature Reviews Microbiology · doi:10.1038/s41579-022-00822-w · Cited by 424
Brümmer, L. E., Katzenschlager, S., Gaeddert, M., Erdmann, C., Schmitz, S., Bota, M., Grilli, M., Larmann, J., Weigand, M. A., Pollock, N. R., et al. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003735 · Cited by 298
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Sharma, P., Berhane, S., van Wyk, S. S., Nyaaba, N., Domen, J., Taylor, M., Cunningham, J., Davenport, C., Dittrich, S., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub3 · Cited by 225
Idili, A., Parolo, C., Alvarez-Diduk, R., & Merkoçi, A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01222 · Cited by 193
Metadata
- Authors
- Corman, V. M., Haage, V. C., Bleicker, T., Schmidt, M. L., Mühlemann, B., Zuchowski, M., Jo, W. K., Tscheak, P., Möncke-Buchner, E., Müller, M. A., Krumbholz, A., Drexler, J. F., & Drosten, C.
- Venue
- The Lancet Microbe
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 2
- Issue
- 7
- Pages
- e311-e319
- ISSN
- 2666-5247 (ISSN-L)
- OpenAlex
- W3146201568
- Cited by
- 340
- References
- 28
- FWCI
- 22.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.