The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
A new method for the model‐independent assessment of thickness in three‐dimensional images
Hildebrand, T., & Rüegsegger, P. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1340694.x · Cited by 1,818
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
EPIDEMIOLOGY OF VERTEBRAL FRACTURES IN WOMEN
MELTON, L. J., KAN, S. H., FRYE, M. A., WAHNER, H. W., O'FALLON, W. M., & RIGGS, B. L. (1989) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115204 · Cited by 924
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603
The relationship between the elasticity tensor and the fabric tensor
Cowin, S. C. (1985) · Mechanics of Materials · doi:10.1016/0167-6636(85)90012-2 · Cited by 570
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Bobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Design and properties of 3D scaffolds for bone tissue engineering
Gómez, S., Vlad, M. D., López, J., & Fernández, E. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.06.032 · Cited by 477
Sornay-Rendu, E., Boutroy, S., Munoz, F., & Delmas, P. D. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061206 · Cited by 454
Metadata
- Authors
- Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 1999-07
- Volume
- 25
- Issue
- 1
- Pages
- 55-60
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2135587550
- Cited by
- 718
- References
- 29
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. https://app.cochat.ai/papers/10.1016/s8756-3282(99)00098-8
- The paper
- Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999). The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone. https://doi.org/10.1016/s8756-3282(99)00098-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.