Equivalence of information from single frequency v. bioimpedance spectroscopy in bodybuilders
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In bioelectrical impedance spectroscopy (BIS), it is assumed that the current path is only extracellular at the lowest frequencies and that it is both extra- and intracellular at the highest frequencies. We tested validity of BIS assumptions in bodybuilders who have an increased intracellular volume due to hypertrophy of muscle fibres. The study was observational cross-sectional in a study group of thirty professional bodybuilders compared with thirty control subjects. Resistance (R) and reactance (Xc) vector components fitting the Cole's arc with BIS (SFB3 analyser) were compared with components at 50 kHz frequency. The average Cole's arc in bodybuilders was significantly smaller and shifted to the left in the R–Xc plane (both R and Xc values were smaller at any individual frequency). The ratio of Xc at 5 kHz and Xc at the characteristic frequency was 70 % in bodybuilders and 64 % in control subjects, indicating a huge intracellular flow of the electric current at low frequencies in both groups (expected ratio close to 0 if the current path was extracellular). As a consequence of a common path, the correlation coefficient between R values at 50 kHz and at other frequencies (from 0 to infinity) was 0·94 to 1·00. The correlation between total body water estimated with BIS or with R at 50 kHz was 0·98. Hence, there was equivalence between information provided by the vector components R and Xc at 50 kHz and that provided by 496 correlated vectors that were measured with BIS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
Piccoli, A., Rossi, B., Pillon, L., & Bucciante, G. (1994) · Kidney International · doi:10.1038/ki.1994.305 · Cited by 711
Self-citationSun, S. S., Chumlea, W. C., Heymsfield, S. B., Lukaski, H. C., Schoeller, D., Friedl, K., Kuczmarski, R. J., Flegal, K. M., Johnson, C. L., & Hubbard, V. S. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.2.331 · Cited by 692 · cited 7×
“Prediction equations based on impedance may be flawed in extremes of body composition, particularly if tissue hydration is abnormal (Piccoli et al. 1998; Ellis, 2000; Sun et al. 2003; Piccoli, 2004).”
InfluentialWhole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429 · cited 4×
“…part of the current still passes through cells and that at the highest frequencies, part of the current still cannot fully penetrate all cells (Foster & Lukaski, 1996; De Lorenzo et al. 1997; Matthie et al. 1998; Gudivaka et al. 1999; Faes et al. 1999; Grimnes & Martinsen, 2000; Ellis, 2000).”
InfluentialWhy bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361 · cited 2×
“Short-and long-term CV for impedance measurements range between 1·8 and 2·9 % respectively (Houtkooper et al. 1996).”
Muscle ultrastructural characteristics of elite powerlifters and bodybuilders
MacDougall, J. D., Sale, D. G., Elder, G. C. B., & Sutton, J. R. (1982) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421171 · Cited by 205 · cited 1×
“It has been proved with muscle biopsy in bodybuilders that muscle fibres undergo mainly hypertrophy with a little contribution of hyperplasia (MacDougall et al. 1982, 1984).”
Cited by
Campa, F., Toselli, S., Mazzilli, M., Gobbo, L. A., & Coratella, G. (2021) · Nutrients · doi:10.3390/nu13051620 · Cited by 315
“Indeed, higher phase angle values are associated with higher muscle mass or acute dehydration, while lower phase angle values are related to lower muscle mass, acute hyperhydration, or chronic dehydration [31,46,98].”
BackgroundMethodMoon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Bioimpedance measurements of human body composition: critical analysis and outlook
Matthie, J. R. (2008) · Expert Review of Medical Devices · doi:10.1586/17434440.5.2.239 · Cited by 199
Bioimpedance basics and phase angle fundamentals
Ward, L. C., & Brantlov, S. (2023) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-022-09780-3 · Cited by 197
Lukaski, H. C., Vega Diaz, N., Talluri, A., & Nescolarde, L. (2019) · Nutrients · doi:10.3390/nu11040809 · Cited by 168
“They observed similar findings in a comparison of the same BI instruments in body builders and non-resistance training men [85].”
Result
Metadata
- Authors
- Piccoli, A., Pastori, G., Codognotto, M., & Paoli, A.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2007-01
- Volume
- 97
- Issue
- 1
- Pages
- 182-192
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2123637132
- Cited by
- 51
- References
- 6
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.