Electrorotation and dielectrophoresis
The DOI matches its Crossref record.
Abstract
Using microelectrode structures, various forms of electric fields, such as non-uniform, rotating and travelling wave, can be imposed on particles of sizes ranging from proteins and viruses to micro-organisms and cells. Each type of particle responds to the forces exerted on them in a unique way, allowing for their controlled and selective manipulation as well as their characterization. Moreover, particles of the same type but of different viability can be distinguished in a simple, reliable manner. This review outlines the principles that govern the way in which bioparticles respond to these various field types, and how they can be exploited. Examples of current and potential biotechnological and biomedical applications are given, along with a critical comparison of current techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alternating electric fields arrest cell proliferation in animal tumor models and human brain tumors
Kirson, E. D., Dbalý, V., Tovaryš, F., Vymazal, J., Soustiel, J. F., Itzhaki, A., Mordechovich, D., Steinberg-Shapira, S., Gurvich, Z., Schneiderman, R., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702916104 · Cited by 894
Single cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 445
Microsample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
Tumor treating fields: A new frontier in cancer therapy
Davies, A. M., Weinberg, U., & Palti, Y. (2013) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12112 · Cited by 193
Chen, J., Xue, C., Zhao, Y., Chen, D., Wu, M.-H., & Wang, J. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059804 · Cited by 160
“By measuring the rotating rate as a function of the applied frequency, this method is capable of collecting membrane permittivity and cytoplasm conductivity of single cells [25–32].”
MethodDielectric measurement of individual microtubules using the electroorientation method
Minoura, I., & Muto, E. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.071324 · Cited by 156
“To characterize the electrostatic/dynamic properties of microtubules, we performed dielectric measurements by using the electroorientation method (20, 21 ).”
MethodTumor treating fields: concept, evidence and future
Pless, M., & Weinberg, U. (2011) · Expert Opinion on Investigational Drugs · doi:10.1517/13543784.2011.583236 · Cited by 78
“It was thought that such electric fields have no meaningful biological effect on cells [4,6-9].”
Background
Metadata
- Authors
- GOATER, A. D., & PETHIG, R.
- Venue
- Parasitology
- Publisher
- Cambridge University Press (CUP)
- Published
- 1999-11
- Volume
- 117
- Issue
- 7
- Pages
- 177-189
- ISSN
- 0031-1820 (ISSN-L)
- 1469-8161
- OpenAlex
- W2061055915
- Cited by
- 81
- References
- 0
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.