The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Single cell dielectric spectroscopy
Abstract
Over the last century a number of techniques have been developed which allow the measurement of the dielectric properties of biological particles in fluid suspension. The majority of these techniques are limited by the fact that they only provide an average value for the dielectric properties of a collection of particles. More recently, with the advent of microfabrication techniques and the Lab-on-a-chip, it has been possible to perform dielectric spectroscopic experiments on single biological particles suspended in physiological media. In this paper we review current methods for single cell dielectric spectroscopy. We also discuss alternative single cell dielectric measurement techniques, specifically the ac electrokinetic methods of dielectrophoresis and electrorotation. Single cell electrical impedance spectroscopy is also discussed with relevance to a microfabricated flow cytometer. We compare impedance spectroscopy data obtained from measurements made using a microfabricated flow cytometer with simulation data obtained using an equivalent circuit model for the device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
An approach to electrical modeling of single and multiple cells
Gowrishankar, T. R., & Weaver, J. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0636434100 · Cited by 204
Stewart Jr., D. A., Gowrishankar, T. R., Smith, K. C., & Weaver, J. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856030 · Cited by 52 · cited 2×
“Several approaches have been used to model the dielectric properties of single particles in suspension, including the finite element method [80], Maxwell’s mixture theory (MMT) [33, 80, 85], equivalent circuit model (ECM) [27, 86], the boundary element method [87], the transport lattice method [88,89] and the finite d…”
Method
Cited by
A fast impedance-based antimicrobial susceptibility test
Spencer, D. C., Paton, T. F., Mulroney, K. T., Inglis, T. J. J., Sutton, J. M., & Morgan, H. (2020) · Nature Communications · doi:10.1038/s41467-020-18902-x · Cited by 183
Self-citationDual-frequency impedance assays for intracellular components in microalgal cells
Tang, T., Liu, X., Yuan, Y., Kiya, R., Shen, Y., Zhang, T., Suzuki, K., Tanaka, Y., Li, M., Hosokawa, Y., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00721a · Cited by 26
Lei, K. F., Wu, M.-H., Hsu, C.-W., & Chen, Y.-D. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)16588-6 · Cited by 12
Metadata
- Authors
- Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2006-12-15
- Volume
- 40
- Issue
- 1
- Pages
- 61-70
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1977248858
- Cited by
- 445
- References
- 3
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single cell dielectric spectroscopy. https://app.cochat.ai/papers/10.1088/0022-3727/40/1/s10
- The paper
- Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007). Single cell dielectric spectroscopy. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/40/1/s10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.