Developing medical device technologies from users' perspectives: A theoretical framework for involving users in the development process
The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.
Abstract
Objectives: The aim of this study was to suggest an acceptable and generic theoretical framework for involving various types of users in the medical device technology (MDT) development process (MDTDP). Methods: The authors propose a theoretical framework suggesting different routes, methods and stages through which various types of medical device users can be involved in the MDTDP. Results: The suggested framework comprises two streams of users’ involvement in MDT development, that is, what might be called the end users’ stream and the professional users’ stream for involving these two groups respectively in the process of developing both simple and more complex and innovative medical devices from conceptualization through to the market deployment. This framework suggests various methods that can be used for users’ involvement at different stages of the MDT lifecycle. To illustrate the application of the framework, several MDT development scenarios and device exemplars are presented. Conclusions: Development of medical devices from users’ perspectives requires not only the involvement of healthcare professionals but also that of the ultimate end users, that is, patients, people with disabilities and/or special needs, and their caregivers. The evidence shows that such end users quickly discard devices that do not fulfill their personal expectations, even though both manufacturers and healthcare professionals may consider those end users’ requirements met. Developers and manufacturers need to recognize this potent potential discrepancy between the parties involved, and involve end users and professional healthcare staff directly in the MDTDP. The framework, the authors contend, is a step forward in helping medical device manufacturers plan and make decisions about users’ involvement at different stages of the MDTDP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“it is highly compatible with the more in-depth approaches that have evolved within the disciplines of information systems and human computer interaction, such as human-centered and user-centered design [6,38,39].”
From The Person-Based Approach to Intervention Development: Application to Digital Health-Related Behavior Change Interventions (2015) · cites this paper as [38]
Experimental — accuracy not yet measuredIn the citing paper
“Theoretical frameworks regarding user-centered design (UCD) have been used as guidelines during the development processes of telecare products and services [16-22].”
From Experiences of Multidisciplinary Development Team Members During User-Centered Design of Telecare Products and Services: A Qualitative Study (2014) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Framework for design and evaluation of complex interventions to improve health
Campbell, M. (2000) · BMJ · doi:10.1136/bmj.321.7262.694 · Cited by 3,474 · cited 1×
“For example, the technology transfer model (35); the economic evaluation in health technology assessment (31); a framework for the development and evaluation of randomized controlled trials (8;25); a model of user engagement in medical device development (14), and the integration of a Bayesian framework in the medical…”
MethodAn Investigation into the New Product Process: Steps, Deficiencies, and Impact
Cooper, R. G., & Kleinschmidt, E. J. (1986) · Journal of Product Innovation Management · doi:10.1016/0737-6782(86)90030-5 · Cited by 1,034
Using usability heuristics to evaluate patient safety of medical devices
Zhang, J., Johnson, T. R., Patel, V. L., Paige, D. L., & Kubose, T. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00060-1 · Cited by 591
Benefits of and barriers to involving users in medical device technology development and evaluation
Shah, S. G. S., & Robinson, I. (2007) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462307051677 · Cited by 299
Self-citationUsability in the real world: assessing medical information technologies in patients’ homes
Kaufman, D. R., Patel, V. L., Hilliman, C., Morin, P. C., Pevzner, J., Weinstock, R. S., Goland, R., Shea, S., & Starren, J. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00056-x · Cited by 254
The Iterative Use of Economic Evaluation as Part of the Process of Health Technology Assessment
Sculpher, M., Drummond, M., & Buxton, M. (1997) · Journal of Health Services Research & Policy · doi:10.1177/135581969700200107 · Cited by 208
Toward the development of consumer-based criteria for the evaluation of assistive devices
Batavia, A. I., & Hammer, G. S. (1990) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1990.10.0425 · Cited by 199
Capturing user requirements in medical device development: the role of ergonomics
Martin, J. L., Murphy, E., Crowe, J. A., & Norris, B. J. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/r01 · Cited by 160
Applying Human Factors to the Design of Medical Equipment: Patient-Controlled Analgesia
Lin, L., Isla, R., Doniz, K., Harkness, H., Vicente, K. J., & Doyle, D. J. (1998) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009928203196 · Cited by 154
The user action framework: a reliable foundation for usability engineering support tools
Andre, T. S., Hartson, H. R., Belz, S. M., & McCreary, F. A. (2001) · International Journal of Human-Computer Studies · doi:10.1006/ijhc.2000.0441 · Cited by 148
User involvement in healthcare technology development and assessment: Structured literature review
Ghulam Sarwar Shah, S., & Robinson, I. (2006) · International Journal of Health Care Quality Assurance · doi:10.1108/09526860610687619 · Cited by 144
Self-citationNew product development process: Stages and successes in the medical products industry
Rochford, L., & Rudelius, W. (1997) · Industrial Marketing Management · doi:10.1016/s0019-8501(96)00115-0 · Cited by 137
Obradovich, J. H., & Woods, D. D. (1996) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872096778827251 · Cited by 124
Kittel, A., Marco, A. D., & Stewart, H. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110066785 · Cited by 119
Vallejo‐Torres, L., Steuten, L., Buxton, M. J., Girling, A. J., Lilford, R. J., & Young, T. P. (2008) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462308080604 · Cited by 112
Garmer, K., Ylvén, J., & Karlsson, M. (2003) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2003.07.005 · Cited by 93
Articulating User Needs in Collaborative Design: Towards an Activity-Theoretical Approach
Miettinen, R., & Hasu, M. (2002) · Computer Supported Cooperative Work (CSCW) · doi:10.1023/a:1015256909032 · Cited by 88
Issues and challenges of involving users in medical device development
Bridgelal Ram, M., Grocott, P. R., & Weir, H. C. M. (2008) · Health Expectations · doi:10.1111/j.1369-7625.2007.00464.x · Cited by 83
Prototyping in industrial software projects-bridging the gap between theory and practice
Lichter, H., Schneider-Hufschmidt, M., & Zullighoven, H. (1994) · IEEE Transactions on Software Engineering · doi:10.1109/32.368126 · Cited by 81
Medical device technologies: who is the user?
Shah, S. G. S., & Robinson, I. (2008) · International Journal of Healthcare Technology and Management · doi:10.1504/ijhtm.2008.017372 · Cited by 71
Self-citationGarmer, K., Liljegren, E., Osvalder, A., & Dahlman, S. (2002) · International Journal of Industrial Ergonomics · doi:10.1016/s0169-8141(01)00060-9 · Cited by 70
Cognitive engineering methods as usability evaluation tools for medical equipment
Liljegren, E., & Osvalder, A. (2004) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2004.01.008 · Cited by 56
Approach to the analysis of user requirements in assistive technology
Bühler, C. (1996) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(95)00049-6 · Cited by 54
A model of user engagement in medical device development
Grocott, P., Weir, H., & Bridgelal Ram, M. (2007) · International Journal of Health Care Quality Assurance · doi:10.1108/09526860710819422 · Cited by 46
Autonomous robot technology for advanced wheelchair and robotic aids for people with disabilities
Bühler, C., Hoelper, R., Hoyer, H., & Humann, W. (1995) · Robotics and Autonomous Systems · doi:10.1016/0921-8890(95)00030-j · Cited by 46
Constructing Clinical Use: An Activity-Theoretical Perspective on Implementing New Technology
Hasu, M. (2000) · Technology Analysis and Strategic Management · doi:10.1080/09537320050130606 · Cited by 38
A task based ‘design for all’ support tool
Marshall, R., Case, K., Oliver, R., Gyi, D. E., & Porter, J. M. (2002) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/s0736-5845(02)00021-2 · Cited by 36
New medical devices. Invention, development and use
Banta, D. (1989) · Health Policy · doi:10.1016/0168-8510(89)90007-9 · Cited by 29
Experiences of new product development in the medical device industry.
Dixon, D., Brown, A., Meenan, B. J., & Eatock, J. (2006) · PubMed · Cited by 24
A Methodology for a Structured Survey of the Healthcare Literature related to Medical Device Users
Ram, M. B., Campling, N. C., Grocott, P., & Weir, H. (2008) · Evaluation · doi:10.1177/1356389007084676 · Cited by 23
Evaluating a new mobility device: feedback from women with disabilities in India
J. Mulholland, S., Packer, T. L., Laschinger, S. J., Lysack, J. T., Wyss, U. P., & Balaram, S. (2000) · Disability and Rehabilitation · doi:10.1080/096382800296962 · Cited by 23
Involving patients in research ‐ Setting up a service users’ advisory group
Rhodes, P., Nocon, A., Wright, J., & Harrison, S. (2001) · Journal of Management in Medicine · doi:10.1108/02689230110394679 · Cited by 19
New Medical Devices; Invention, Development, and Use
Ekelman, K. B. (2013) · Cited by 16
Sheredos, S. J., & Cupo, M. E. (1997) · Technology and Disability · doi:10.3233/tad-1997-71-203 · Cited by 11
Types and Timing of Inter–organizational Communication in New Product Development
Hummel, M. J. M., van Rossum, W., Omta, O., Verkerke, G. J., & Rakhorst, G. (2001) · Creativity and Innovation Management · doi:10.1111/1467-8691.00225 · Cited by 11
Image transfer and computer-supported cooperative diagnosis
Handels, H., Rinast, E., Busch, C., Hahn, C., Kuhn, V., Miehe, J., Roßmanith, C., Seibert, F., & Will, A. (1997) · Journal of Telemedicine and Telecare · doi:10.1258/1357633971930940 · Cited by 8
Research works printed but not linked: 4
- 2003, Medical device regulations: Global overview and guiding principles
- 1. Anderson GJM. Shaping the future: using voice of the customer methodology to develop inhaler design. In: Dalby RN, Byron PR, Peart J, Farr SJ, eds., Proceedings of Respiratory Drug Delivery VIII Conference. Tucson, AZ. Serentec Press. May 12-16,2002;1:179-188.
- 10.1016/s1055-4181(96)00017-9 · doi:10.1016/s1055-4181(96)00017-9
- 2000, A framework for development and evaluation of RCTs for complex interventions to improve health
Cited by
Yardley, L., Morrison, L., Bradbury, K., & Muller, I. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4055 · Cited by 1,442
Participatory Design in Gerontechnology: A Systematic Literature Review
Merkel, S., & Kucharski, A. (2019) · The Gerontologist · doi:10.1093/geront/gny034 · Cited by 209
Money, A. G., Barnett, J., Kuljis, J., Craven, M. P., Martin, J. L., & Young, T. (2011) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-11-15 · Cited by 203
“development process [3].”
Zidaru, T., Morrow, E. M., & Stockley, R. (2021) · Health Expectations · doi:10.1111/hex.13299 · Cited by 119
WHAT ARE USER PERSPECTIVES OF EXOSKELETON TECHNOLOGY? A LITERATURE REVIEW
Hill, D., Holloway, C., Ramírez, D. Z. M., Smitham, P. J., & Pappas, Y. (2017) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462317000460 · Cited by 155
Metadata
- Authors
- Shah, S. G. S., Robinson, I., & AlShawi, S.
- Affiliations
- Brunel University of London (GB)
- Venue
- International Journal of Technology Assessment in Health Care
- Publisher
- Cambridge University Press (CUP)
- Published
- 2009-10
- Volume
- 25
- Issue
- 4
- Pages
- 514-521
- ISSN
- 0266-4623 (ISSN-L)
- 1471-6348
- OpenAlex
- W2111321335
- Cited by
- 237
- References
- 37
- Citations by year
- 2026: 4 · 2025: 13 · 2024: 14 · 2023: 13 · 2022: 22 · 2021: 29 · 2020: 21 · 2019: 19 · 2018: 19 · 2017: 13 · 2016: 15 · 2015: 6 · 2014: 13 · 2013: 16 · 2012: 11
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Technology Assessment in Health Care (publishedVersion)
- PubMed (publishedVersion)
- Brunel University Research Archive (BURA) (Brunel University London) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/F063822/1)
- Topics
- Health Sciences › Health Professions › General Health Professions › Mental Health and Patient Involvement
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- medical device development, user participation, end users, healthcare workers, theoretical framework, medical device lifecycle, patient involvement, caregivers, people with disabilities, user requirements, medical device manufacturers
- MeSH terms
- Community Participation, Equipment and Supplies, Equipment Design, Health Personnel, Humans, Self-Help Devices, Biomedical Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.