High-Resolution Transmission Electron Microscopy Using Negative Spherical Aberration
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A novel imaging mode for high-resolution transmission electron microscopy is described. It is based on the adjustment of a negative value of the spherical aberration C S of the objective lens of a transmission electron microscope equipped with a multipole aberration corrector system. Negative spherical aberration applied together with an overfocus yields high-resolution images with bright-atom contrast. Compared to all kinds of images taken in conventional transmission electron microscopes, where the then unavoidable positive spherical aberration is combined with an underfocus, the contrast is dramatically increased. This effect can only be understood on the basis of a full nonlinear imaging theory. Calculations show that the nonlinear contrast contributions diminish the image contrast relative to the linear image for a positive-C S setting whereas they reinforce the image contrast relative to the linear image for a negative-C S setting. The application of the new mode to the imaging of oxygen in SrTiO3 and YBa2Cu3O7 demonstrates the benefit to materials science investigations. It allows us to image directly, without further image processing, strongly scattering heavy-atom columns together with weakly scattering light-atom columns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stadelmann, P. A. (1987) · Ultramicroscopy · doi:10.1016/0304-3991(87)90080-5 · Cited by 2,018 · cited 1×
“The two images were calculated for a specimen thickness of 4 nm, a defocus of 8 nm, and a spherical aberration of 240 mm, using the linear and nonlinear imaging subroutines of the EMS simulation package ~Stadelmann, 1987!.”
MethodOxygen ordering and the orthorhombic-to-tetragonal phase transition inYBa2Cu3O7−x
Jorgensen, J. D., Beno, M. A., Hinks, D. G., Soderholm, L., Volin, K. J., Hitterman, R. L., Grace, J. D., Schuller, I. K., Segre, C. U., Zhang, K., et al. (1987) · Physical Review B · doi:10.1103/physrevb.36.3608 · Cited by 1,173 · cited 1×
“The same applies to the cuprate hightemperature superconductors, which have perovskite-derived structures: The oxygen occupancy of certain lattice sites controls sensitively the charge carrier density in the superconducting planes ~Jorgensen et al., 1987; Poole et al., 1995!.”
BackgroundElectron microscopy image enhanced
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B., & Urban, K. (1998) · Nature · doi:10.1038/33823 · Cited by 1,057 · cited 3×
“With the aberration-corrected transmission electron microscope ~Rose, 1990; Haider et al., 1998b!, the direct imaging, with a single image, of atomic columns can be achieved.”
MethodSelf-citationArtificial charge-modulationin atomic-scale perovskite titanate superlattices
Ohtomo, A., Muller, D. A., Grazul, J. L., & Hwang, H. Y. (2002) · Nature · doi:10.1038/nature00977 · Cited by 1,009 · cited 1×
“…of the high-angle annular dark-field technique used ~Pennycook et al., 1997!, only the cation sublattice consisting of strongly scattering atoms could be imaged in a recent study of SrTiO3 and LaTiO3 superlattices, but not the weakly scattering atoms of the oxygen sublattice ~Ohtomo et al., 2002!.”
MethodThe Theoretical Resolution Limit of the Electron Microscope
Scherzer, O. (1949) · Journal of Applied Physics · doi:10.1063/1.1698233 · Cited by 915 · cited 1×
“Scherzer’s defocus maximizing the phasecontrast of a weak-phase object ~Scherzer, 1949!, Lichte’s defocus of least confusion ~Lichte, 1991! minimizing contrast delocalization ~Lichte, 1991; Coene & Jansen, 1992!, and the minimum phase-contrast defocus ~Heinemann, 1971!.”
BackgroundTagantsev, A. K., Stolichnov, I., Colla, E. L., & Setter, N. (2001) · Journal of Applied Physics · doi:10.1063/1.1381542 · Cited by 602 · cited 1×
“Lattice defects and the variations of the chemical composition have an influence on the materials properties and hence also the device performance ~Waser, 1997; Tagantsev et al., 2001!.”
BackgroundAtomic-Resolution Imaging of Oxygen in Perovskite Ceramics
Jia, C. L., Lentzen, M., & Urban, K. (2003) · Science · doi:10.1126/science.1079121 · Cited by 567 · cited 1×
“…imaging mode in which the contrast of weakly scattering light atoms in the vicinity of strongly scattering heavy atoms is dramatically enhanced ~Jia et al., 2003!. Applying this imaging mode to the dielectric SrTiO3 and the high-temperature superconductor YBa2Cu3O7 not only allowed us to image…”
BackgroundSelf-citationA spherical-aberration-corrected 200kV transmission electron microscope
Haider, M., Rose, H., Uhlemann, S., Schwan, E., Kabius, B., & Urban, K. (1998) · Ultramicroscopy · doi:10.1016/s0304-3991(98)00048-5 · Cited by 426 · cited 3×
“With the aberration-corrected transmission electron microscope ~Rose, 1990; Haider et al., 1998b!, the direct imaging, with a single image, of atomic columns can be achieved.”
MethodSelf-citationStructure of (CuO)2 double layers in superconducting YBa2Cu3O7
Zandbergen, H. W., Gronsky, R., Wang, K., & Thomas, G. (1988) · Nature · doi:10.1038/331596a0 · Cited by 312 · cited 2×
“Using the focus-variation method, the amplitude and phase modulation of the electron wave owing to weakly and strongly scattering atom columns can be extracted from a defocus series of typically 15 to 20 images: An early application of the method by Coene et al. ~1992! revealed light and heavy atoms in YBa2Cu4O8 @100#…”
BackgroundInfluentialHigh-resolution imaging with an aberration-corrected transmission electron microscope
Lentzen, M., Jahnen, B., Jia, C. L., Thust, A., Tillmann, K., & Urban, K. (2002) · Ultramicroscopy · doi:10.1016/s0304-3991(02)00139-0 · Cited by 214 · cited 3×
“21, ~6! the aberration function is negative up to the information limit ~Lentzen et al., 2002!, yielding a broad Scherzer passband with a phase deviation close to 2p/2.”
BackgroundSelf-citation
Cited by
Switching the electrical resistance of individual dislocations in single-crystalline SrTiO3
Szot, K., Speier, W., Bihlmayer, G., & Waser, R. (2006) · Nature Materials · doi:10.1038/nmat1614 · Cited by 1,651
Atomic structure of sensitive battery materials and interfaces revealed by cryo–electron microscopy
Li, Y., Li, Y., Pei, A., Yan, K., Sun, Y., Wu, C.-L., Joubert, L.-M., Chin, R., Koh, A. L., Yu, Y., et al. (2017) · Science · doi:10.1126/science.aam6014 · Cited by 1,547
Direct Imaging of Lattice Atoms and Topological Defects in Graphene Membranes
Meyer, J. C., Kisielowski, C., Erni, R., Rossell, M. D., Crommie, M. F., & Zettl, A. (2008) · Nano Letters · doi:10.1021/nl801386m · Cited by 1,234
Jia, C.-L., Mi, S.-B., Urban, K., Vrejoiu, I., Alexe, M., & Hesse, D. (2008) · Nature Materials · doi:10.1038/nmat2080 · Cited by 520
Self-citationTheory and applications of free-electron vortex states
Bliokh, K. Y., Ivanov, I. P., Guzzinati, G., Clark, L., Van Boxem, R., Béché, A., Juchtmans, R., Alonso, M. A., Schattschneider, P., Nori, F., et al. (2017) · Physics Reports · doi:10.1016/j.physrep.2017.05.006 · Cited by 366
Electron Microscopy of Solid Catalysts—Transforming from a Challenge to a Toolbox
Su, D. S., Zhang, B., & Schlögl, R. (2015) · Chemical Reviews · doi:10.1021/cr500084c · Cited by 258
Jinschek, J. R. (2014) · Chem. Commun. · doi:10.1039/c3cc49092k · Cited by 172
Metadata
- Authors
- Jia, C.-L., Lentzen, & Urban, K.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-03-17
- Volume
- 10
- Issue
- 02
- Pages
- 174-184
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2137167699
- Cited by
- 176
- References
- 13
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.