Automating the Collection of Ultrathin Serial Sections for Large Volume TEM Reconstructions
The DOI matches its Crossref record.
Abstract
Extended abstract of a paper presented at Microscopy and Microanalysis 2006 in Chicago, Illinois, USA, July 30 – August 3, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microglia Sculpt Postnatal Neural Circuits in an Activity and Complement-Dependent Manner
Schafer, D. P., Lehrman, E. K., Kautzman, A. G., Koyama, R., Mardinly, A. R., Yamasaki, R., Ransohoff, R. M., Greenberg, M. E., Barres, B. A., & Stevens, B. (2012) · Neuron · doi:10.1016/j.neuron.2012.03.026 · Cited by 4,089
Van Dijk, K. R. A., Hedden, T., Venkataraman, A., Evans, K. C., Lazar, S. W., & Buckner, R. L. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00783.2009 · Cited by 1,844
Network anatomy and in vivo physiology of visual cortical neurons
Bock, D. D., Lee, W.-C. A., Kerlin, A. M., Andermann, M. L., Hood, G., Wetzel, A. W., Yurgenson, S., Soucy, E. R., Kim, H. S., & Reid, R. C. (2011) · Nature · doi:10.1038/nature09802 · Cited by 870
Distinct Profiles of Myelin Distribution Along Single Axons of Pyramidal Neurons in the Neocortex
Tomassy, G. S., Berger, D. R., Chen, H.-H., Kasthuri, N., Hayworth, K. J., Vercelli, A., Seung, H. S., Lichtman, J. W., & Arlotta, P. (2014) · Science · doi:10.1126/science.1249766 · Cited by 600
“The cerebral cortex was cut and collected on kapton tape (glow discharged to prevent wrinkling of sections) with an ATUM (automatic tape-collecting ultra microtome) at 30 nm slice thickness(27, 28)(28).”
MethodSelf-citationMicro-Optical Sectioning Tomography to Obtain a High-Resolution Atlas of the Mouse Brain
Li, A., Gong, H., Zhang, B., Wang, Q., Yan, C., Wu, J., Liu, Q., Zeng, S., & Luo, Q. (2010) · Science · doi:10.1126/science.1191776 · Cited by 521
Enhanced FIB-SEM systems for large-volume 3D imaging
Xu, C. S., Hayworth, K. J., Lu, Z., Grob, P., Hassan, A. M., García-Cerdán, J. G., Niyogi, K. K., Nogales, E., Weinberg, R. J., & Hess, H. F. (2017) · eLife · doi:10.7554/elife.25916 · Cited by 411
“Finally, post-staining is commonly used in TEM and ATUM-SEM (Hayworth et al., 2006) sections to enhance contrast, whereas FIB-SEM must image the block surface without benefit of the extra contrast from post-staining.”
BackgroundMethodInfluentialSelf-citationHoffman, D. P., Shtengel, G., Xu, C. S., Campbell, K. R., Freeman, M., Wang, L., Milkie, D. E., Pasolli, H. A., Iyer, N., Bogovic, J. A., et al. (2020) · Science · doi:10.1126/science.aaz5357 · Cited by 349
Volume electron microscopy for neuronal circuit reconstruction
Briggman, K. L., & Bock, D. D. (2012) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2011.10.022 · Cited by 335
Exploring the third dimension: Volume electron microscopy comes of age
Peddie, C. J., & Collinson, L. M. (2014) · Micron · doi:10.1016/j.micron.2014.01.009 · Cited by 330
Elastic volume reconstruction from series of ultra-thin microscopy sections
Saalfeld, S., Fetter, R., Cardona, A., & Tomancak, P. (2012) · Nature Methods · doi:10.1038/nmeth.2072 · Cited by 329
A technicolour approach to the connectome
Lichtman, J. W., Livet, J., & Sanes, J. R. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2391 · Cited by 329
Self-citationCellular-resolution connectomics: challenges of dense neural circuit reconstruction
Helmstaedter, M. (2013) · Nature Methods · doi:10.1038/nmeth.2476 · Cited by 313
High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy
Tapia, J. C., Kasthuri, N., Hayworth, K. J., Schalek, R., Lichtman, J. W., Smith, S. J., & Buchanan, J. (2012) · Nature Protocols · doi:10.1038/nprot.2011.439 · Cited by 296
Self-citationVolume scanning electron microscopy for imaging biological ultrastructure
Titze, B., & Genoud, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600024 · Cited by 287
“ATUM-SEM (Hayworth et al., 2006; Schalek et al., 2011, 2012), a serial section technique, offers automated ultrathin section cutting and collection, followed by semi-automated high-throughput SEM imaging.”
MethodHigh-accuracy neurite reconstruction for high-throughput neuroanatomy
Helmstaedter, M., Briggman, K. L., & Denk, W. (2011) · Nature Neuroscience · doi:10.1038/nn.2868 · Cited by 270
High‐resolution, high‐throughput imaging with a multibeam scanning electron microscope
EBERLE, A. L., MIKULA, S., SCHALEK, R., LICHTMAN, J., TATE, M. L. K., & ZEIDLER, D. (2015) · Journal of Microscopy · doi:10.1111/jmi.12224 · Cited by 254
Self-citationStacked Endoplasmic Reticulum Sheets Are Connected by Helicoidal Membrane Motifs
Terasaki, M., Shemesh, T., Kasthuri, N., Klemm, R. W., Schalek, R., Hayworth, K. J., Hand, A. R., Yankova, M., Huber, G., Lichtman, J. W., et al. (2013) · Cell · doi:10.1016/j.cell.2013.06.031 · Cited by 250
“The sections were collected on kapton tape (glow discharged to prevent wrinkling of sections) with the ATUM tape collection device (Hayworth et al., 2006; Tapia et al., 2012).”
Self-citationConnectomic comparison of mouse and human cortex
Loomba, S., Straehle, J., Gangadharan, V., Heike, N., Khalifa, A., Motta, A., Ju, N., Sievers, M., Gempt, J., Meyer, H. S., et al. (2022) · Science · doi:10.1126/science.abo0924 · Cited by 242
High-resolution whole-brain staining for electron microscopic circuit reconstruction
Mikula, S., & Denk, W. (2015) · Nature Methods · doi:10.1038/nmeth.3361 · Cited by 210
Merchan-Pérez, A. (2009) · Frontiers in Neuroanatomy · doi:10.3389/neuro.05.018.2009 · Cited by 191
Structural neurobiology: missing link to a mechanistic understanding of neural computation
Denk, W., Briggman, K. L., & Helmstaedter, M. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3169 · Cited by 191
3D structural imaging of the brain with photons and electrons
Helmstaedter, M., Briggman, K. L., & Denk, W. (2008) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2009.03.005 · Cited by 172
Semi-automated reconstruction of neural circuits using electron microscopy
Chklovskii, D. B., Vitaladevuni, S., & Scheffer, L. K. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.08.002 · Cited by 171
Machine Learning of Hierarchical Clustering to Segment 2D and 3D Images
Nunez-Iglesias, J., Kennedy, R., Parag, T., Shi, J., & Chklovskii, D. B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071715 · Cited by 170
“Relative to other EM modalities, such as serial block face scanning EM (SBFSEM) [27] or serial section transmission EM (ssTEM) [28, 29], FIBSEM has a smaller field of view, but yields isotropic resolution and can be used to reconstruct important circuits.”
MethodSystem-wide Rewiring Underlies Behavioral Differences in Predatory and Bacterial-Feeding Nematodes
Bumbarger, D. J., Riebesell, M., Rödelsperger, C., & Sommer, R. J. (2013) · Cell · doi:10.1016/j.cell.2012.12.013 · Cited by 170
“, 2012) and instrumentation (Denk and Horstmann, 2004; Hayworth et al., 2006; Heymann et al., 2006; Lander et al., 2001) are increasing the throughput and decreasing the cost of suchwork, with the hope of bringing anatomically derived connectivity data into the realm of bioinformatics in the guise of synapse-level con…”
Horstmann, H., Körber, C., Sätzler, K., Aydin, D., & Kuner, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035172 · Cited by 160
“ATUM-SEM uses an electron opaque tape to continuously collect serial sections into ribbons of literally infinite length.”
BackgroundMethodThe power of correlative microscopy: multi-modal, multi-scale, multi-dimensional
Caplan, J., Niethammer, M., Taylor, R. M., & Czymmek, K. J. (2011) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2011.06.010 · Cited by 159
“SEM in combination with serial block face imaging [16 ,48], serial sectioning [49] and array tomography [8], or focused ion beam [50,51] enables 3D imaging of much larger areas than possible with TEM.”
MethodYin, W., Brittain, D., Borseth, J., Scott, M. E., Williams, D., Perkins, J., Own, C., Murfitt, M., Torres, R. M., Kapner, D., et al. (2019) · doi:10.1101/791889 · Cited by 152
SynEM, automated synapse detection for connectomics
Staffler, B., Berning, M., Boergens, K. M., Gour, A., Smagt, P. V. D., & Helmstaedter, M. (2017) · eLife · doi:10.7554/elife.26414 · Cited by 57
“Introduction The ambition to map neuronal circuits in their entirety has spurred substantial methodological developments in large-scale 3-dimensional microscopy (Denk and Horstmann, 2004; Hayworth et al., 2006; Knott et al., 2008; Eberle et al., 2015), making the acquisition of datasets as large as 1 cubic millimeter…”
BackgroundHuman Connectome Mapping and Monitoring Using Neuronanorobots
Martins, N. R. B., Erlhagen, W., & Freitas, Jr. (2016) · Journal of Ethics and Emerging Technologies · doi:10.55613/jeet.v26i1.49 · Cited by 3
“In a type of destructive brain scanning, an automated ultramicrotome produces large amounts of nanometric 30-100 nm thick sections, which are then scanned by either a transmission electron microscope (TEM) or a serial block-face scanning electron microscopy (SBEM), or by an optical microscope (Hayworth et al. 2006; An…”
Method
Metadata
- Authors
- Hayworth, K., Kasthuri, N., Schalek, R., & Lichtman, J.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-31
- Volume
- 12
- Issue
- S02
- Pages
- 86-87
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2153191810
- Cited by
- 176
- References
- 0
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.