Volume Shrinkage of Bone, Brain and Muscle Tissue in Sample Preparation for Micro-CT and Light Sheet Fluorescence Microscopy (LSFM)
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Two methods are especially suited for tomographic imaging with histological detail of macroscopic samples that consist of multiple tissue types (bone, muscle, nerve or fat): Light sheet (based) fluorescence microscopy (LSFM) and micro-computed tomography (micro-CT). Micro-CT requires staining with heavy chemical elements (and thus fixation and sometimes dehydration) in order to make soft tissue imageable when measured alongside denser structures. LSMF requires fixation, decalcification, dehydration, clearing and staining with a fluorescent dye. The specimen preparation of both imaging methods is prone to shrinkage, which is often not mentioned, let alone quantified. In this paper the presence and degree of shrinkage are quantitatively identified for the selected preparation methods/stains. LSFM delivers a volume shrinkage of 17% for bone, 56% for muscle and 62% for brain tissue. The three most popular micro-CT stains (phosphotungstic acid, iodine with potassium iodide, and iodine in absolute ethanol) deliver a volume shrinkage ranging from 10 to 56% for muscle and 27–66% for brain, while bone does not shrink in micro-CT preparation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086 · cited 4×
“In the case of micro-CT, a staining procedure is required to clearly distinguish and resolve soft tissue because of its low X-ray absorption (Metscher, 2009a, 2009b).”
BackgroundInfluentialPAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., & VAN HOOREBEKE, L. (2013) · Journal of Microscopy · doi:10.1111/jmi.12013 · Cited by 212 · cited 1×
“Average Volume Shrinkage An explosion of different staining methods for micro-CT has led to a recent publication studying many different stains, though focusing solely on contrast enhancement, penetration depth, and sample size (Pauwels et al., 2013).”
Background
Cited by
Gignac, P. M., Kley, N. J., Clarke, J. A., Colbert, M. W., Morhardt, A. C., Cerio, D., Cost, I. N., Cox, P. G., Daza, J. D., Early, C. M., et al. (2016) · Journal of Anatomy · doi:10.1111/joa.12449 · Cited by 541
X-ray computed tomography in life sciences
Rawson, S. D., Maksimcuka, J., Withers, P. J., & Cartmell, S. H. (2020) · BMC Biology · doi:10.1186/s12915-020-0753-2 · Cited by 164
Sombke, A., Lipke, E., Michalik, P., Uhl, G., & Harzsch, S. (2015) · Journal of Comparative Neurology · doi:10.1002/cne.23741 · Cited by 144
“The effect of sample preparation on volume shrinkage of rabbit bone, brain, and muscle was recently investigated by Buytaert et al. (2014) and revealed remarkable volume losses (up to 66% for isolated vertebrate brain tissue).”
Background
Metadata
- Authors
- Buytaert, J., Goyens, J., De Greef, D., Aerts, P., & Dirckx, J.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-06-25
- Volume
- 20
- Issue
- 4
- Pages
- 1208-1217
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2313844013
- Cited by
- 173
- References
- 2
- FWCI
- 11.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume Shrinkage of Bone, Brain and Muscle Tissue in Sample Preparation for Micro-CT and Light Sheet Fluorescence Microscopy (LSFM). https://app.cochat.ai/papers/10.1017/s1431927614001329
- The paper
- Buytaert, J., Goyens, J., De Greef, D., Aerts, P., & Dirckx, J. (2014). Volume Shrinkage of Bone, Brain and Muscle Tissue in Sample Preparation for Micro-CT and Light Sheet Fluorescence Microscopy (LSFM). Microscopy and Microanalysis. https://doi.org/10.1017/s1431927614001329
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.