The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Utility of Accurate Mass Tags for Proteome-Wide Protein Identification
Abstract
An enabling capability for proteomics would be the ability to study protein expression on a global scale. While several different separation and analysis options are being investigated to advance the practice of proteomics, mass spectrometry (MS) is rapidly becoming the core instrumental technology used to characterize the large number of proteins that constitute a proteome. To be most effective, proteomic measurements must be high-throughput, ideally allowing thousands of proteins to be identified on a time scale of hours. Most strategies of identification by MS rely on the analysis of enzymatically produced peptides originating from an isolated protein followed by either peptide mapping or tandem MS (MS/MS) to obtain sequence information for a single peptide. In the case of peptide mapping, several peptide masses are needed to unambiguously identify a protein with the typically achieved mass measurement accuracies (MMA). The ability to identify proteins based on the mass of a single peptide (i.e., an accurate mass tag; AMT) is proposed and is largely dependent on the MMA that can be achieved. To determine the MMA necessary to enable the use of AMTs for proteome-wide protein identification, we analyzed the predicted proteins and their tryptic fragments from Saccharomyces cerevisiae and Caenorhabditis elegans. The results show that low ppm (i.e., approximately 1 ppm) level measurements have practical utility for analysis of small proteomes. Additionally, up to 85% of the peptides predicted from these organisms can function as AMTs at sub-ppm MMA levels attainable using Fourier transform ion cyclotron resonance MS. Additional information, such as sequence constraints, should enable even more complex proteomes to be studied at more modest mass measurement accuracies. Once AMTs are established, subsequent high-throughput measurements of proteomes (e.g., after perturbations) will be greatly facilitated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
The Complete Genome Sequence of Escherichia coli K-12
Blattner, F. R., Plunkett, G., Bloch, C. A., Perna, N. T., Burland, V., Riley, M., Collado-Vides, J., Glasner, J. D., Rode, C. K., Mayhew, G. F., et al. (1997) · Science · doi:10.1126/science.277.5331.1453 · Cited by 7,452
Genome Sequence of the Nematode C. elegans : A Platform for Investigating Biology
The C. elegans Sequencing Consortium* (1998) · Science · doi:10.1126/science.282.5396.2012 · Cited by 4,485
Lloyd, S. (1996) · Science · doi:10.1126/science.273.5278.1073 · Cited by 3,088
Signaling Through Scaffold, Anchoring, and Adaptor Proteins
Pawson, T., & Scott, J. D. (1997) · Science · doi:10.1126/science.278.5346.2075 · Cited by 2,256
Rapid identification of proteins by peptide-mass fingerprinting
Pappin, D. J. C., Hojrup, P., & Bleasby, A. J. (1993) · Current Biology · doi:10.1016/0960-9822(93)90195-t · Cited by 1,615
Use of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Large-Cage Zeolite Structures with Multidimensional 12-Ring Channels
Bu, X., Feng, P., & Stucky, G. D. (1997) · Science · doi:10.1126/science.278.5346.2080 · Cited by 329
Strausberg, R. L., Feingold, E. A., Klausner, R. D., & Collins, F. S. (1999) · Science · doi:10.1126/science.286.5439.455 · Cited by 287
Jensen, P. K., Paša-Tolić, L., Anderson, G. A., Horner, J. A., Lipton, M. S., Bruce, J. E., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac990196p · Cited by 231
Self-citation
Cited by
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
The biological impact of mass-spectrometry-based proteomics
Cravatt, B. F., Simon, G. M., & Yates III, J. R. (2007) · Nature · doi:10.1038/nature06525 · Cited by 705
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
The genetics and genomics of cancer
Balmain, A., Gray, J., & Ponder, B. (2003) · Nature Genetics · doi:10.1038/ng1107 · Cited by 573
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
An accurate mass tag strategy for quantitative and high-throughput proteome measurements
Smith, R. D., Anderson, G. A., Lipton, M. S., Pasa-Tolic, L., Shen, Y., Conrads, T. P., Veenstra, T. D., & Udseth, H. R. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200205)2:5<513::aid-prot513>3.0.co;2-w · Cited by 432
Self-citationMass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Proteomics and Immunological Analysis of a Novel Shrimp Allergen, Pen m 2
Yu, C.-J., Lin, Y.-F., Chiang, B.-L., & Chow, L.-P. (2003) · The Journal of Immunology · doi:10.4049/jimmunol.170.1.445 · Cited by 289
Conrads, T. P., Alving, K., Veenstra, T. D., Belov, M. E., Anderson, G. A., Anderson, D. J., Lipton, M. S., Paša-Tolić, L., Udseth, H. R., Chrisler, W. B., et al. (2001) · Analytical Chemistry · doi:10.1021/ac001487x · Cited by 286
Self-citationCurrent trends in quantitative proteomics
Elliott, M. H., Smith, D. S., Parker, C. E., & Borchers, C. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1692 · Cited by 271
Simultaneous Qualitative and Quantitative Analysis of theEscherichia coli Proteome
Silva, J. C., Denny, R., Dorschel, C., Gorenstein, M. V., Li, G.-Z., Richardson, K., Wall, D., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500321-mcp200 · Cited by 265
Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics
Haas, W., Faherty, B. K., Gerber, S. A., Elias, J. E., Beausoleil, S. A., Bakalarski, C. E., Li, X., Villén, J., & Gygi, S. P. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500339-mcp200 · Cited by 261
Gao, J., Xu, J., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001126h · Cited by 257
Zhu, Y., Dou, M., Piehowski, P. D., Liang, Y., Wang, F., Chu, R. K., Chrisler, W. B., Smith, J. N., Schwarz, K. C., Shen, Y., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000686 · Cited by 147
Self-citationInformatics Strategies for Large-Scale Novel Cross-Linking Analysis
Anderson, G. A., Tolic, N., Tang, X., Zheng, C., & Bruce, J. E. (2007) · Journal of Proteome Research · doi:10.1021/pr070035z · Cited by 53
Self-citation
Metadata
- Authors
- Conrads, T. P., Anderson, G. A., Veenstra, T. D., Paša-Tolić, L., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-17
- Volume
- 72
- Issue
- 14
- Pages
- 3349-3354
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1982535455
- Cited by
- 281
- References
- 15
- FWCI
- 16.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.