Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating

Moussy, Francis., Harrison, D. Jed., O'Brien, Darryl W., Rajotte, Ray V. · 1993 · Analytical Chemistry

Abstract

A miniature, needle-type glucose sensor based on a new trilayer membrane configuration has been prepared and evaluated both in vitro and in vivo. The perfluorinated ionomer, Nafion, was used as a protective, biocompatible, outer coating, and poly(o-phenylenediamine) as an inner coating to reduce interference by small, electroactive compounds. Glucose oxidase immobilized in a bovine serum albumin matrix was sandwiched between these coatings. The entire sensor assembly of Pt working electrode and Ag/AgCl reference electrode was 0.5 mm in diameter and could be inserted subcutaneously through an 18-gauge needle. The sensor current closely followed the plasma glucose level during a glucose tolerance test in active dogs, with a delay of 3 min, corresponding to the known lag time for subcutaneous glucose levels. The sensor remained functional after 1 week of implantation, but failed after 2 weeks due to degradation of the reference electrode. In vitro tests in pH 7.4 buffer or whole blood show the sensors have good selectivity, sensitivity of about 25 nA/mM, precision of 2-5%, and a 90% response time of 33 s. Stabilization following polarization requires 10-30 min in vitro and 30-40 min in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00063a023

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Moussy, F., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V.
Venue
Analytical Chemistry
Published
1993-08-01
Volume
65
Issue
15
Pages
2072-2077
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2003388886
Cited by
158
References
1
FWCI
13.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.